State assisted-living licensing record · Texas HHSC · record as pulled September 11, 2026· Not the federal nursing home survey

Silverleaf at Lakeline

11206 Powder Mill Trail, Austin, TX 78750 · Travis County · 13 licensed beds

HHSC licence number 308511 · licensed, enforcement action pending through September 8, 2027 · first licensed December 2008

The licence

Licensed by HHSC · Assisted Living Facility, Type B · Limited Liability Company (LLC)

Certifications and programs, as listed by HHSC
Alzheimer's certification
No
Accepts Medicaid
No
34
Citations on file
Since September 2021
3
HHSC visits
1 routine inspection
27
Life safety and building
Life safety · physical plant · emergency

Position within Texas

34 citations — more than 99% of the 1,995 licensed assisted living facilities in Texas. Compared only within Texas: a citation from HHSC means what it means in Texas, and there is no national assisted living record to compare to. Counted over 5 years, which holds two or three routine inspections. How this is calculated

Not in this record

Scope and severity, and enforcement. HHSC rates each finding on a scope-and-severity scale but does not publish the rating per facility, and it records fines and enforcement actions separately; neither is republished here. What is here is unusual among states: HHSC inspects fire and life safety itself and publishes those findings per facility, so this record carries a real life safety section.

Get an email about Silverleaf at Lakeline

One email when it happens, from the HHSC record as it is pulled each month. No account; stop it any time with one click.

Which alerts

This is the state licensing record, not the federal nursing home survey. Your address is used for these alerts and nothing else.

Life safety and building citations

The citations about the building itself — fire and life safety, physical plant and emergency management. Usually the maintenance side’s to fix.

How that compares

Citations on file over 5 years

Compared with the median licensed assisted living facility in Texas. Within-state only.

This facility34Texas median2
Citations on file over 5 years, compared
MeasureCitations
This facility34
Median facility in Texas2

Visit history

Citations at each HHSC visit
252024-0892025-04
Citations at each HHSC visit
VisitTypeCitations
August 16, 2024life safety code inspection25
April 24, 2025health inspection9
April 24, 2025comprehensive inspection0

What the citations cover

Citations by category (TagProof's grouping)
  • Life safety 20
  • Physical plant 6
  • Food service 2
  • Records and administration 2
  • Other 4
Citations by category
CategoryCitations
Life safety20
Physical plant6
Food service2
Records and administration2
Resident care2
Staffing and training1
Emergency management1

Every visit on file since September 2021

As published by HHSC, newest first, including visits that cited nothing. The wording is HHSC’s own.

April 24, 2025 — comprehensive inspection, nothing cited

August 16, 2024 — life safety code inspection, 25 citations

Citations from the life safety code inspection on August 16, 2024
What HHSC foundCorrected
Facility failed to provide one of the listed fire sprinkler systems according to the requirements of 32.2.3.5 in NFPA 101 Chapter 32.—
The facility failed to keep documentation about the fire sprinkler system onsite at the facility.—
The facility failed to keep documentation about the fire alarm system onsite at the facility.—
The facility failed to check gas heating systems prior to the heating season and to maintain records of the those checks.—
The facility failed to ensure a ramp, walk or step had a uniform walking surface, had a slope no greater than 1:12 and that new ramps were at least 36 inches wide.—
The facility failed to maintain outdoor areas in good condition and to keep outdoor areas free of fire or health hazards.—
The facility failed to ensure equipment could be accessed to the facility could inspect, test, and service the equipment.—
The facility failed to provide the minimum levels of illumination required in the facility.—
The facility failed to inspect, test, and maintain fire sprinkler system components.—
The facility failed to protect the attic according to the referenced codes and standards.—
The facility failed to maintain electrical, heating, and cooling systems so they worked safely.—
The facility failed to ensure resident room doors would latch in their frames.—
The facility failed to provide a manual fire alarm system that met the referenced codes and standards.—
The facility failed to ensure a bedroom had a floor area of at least 100 square feet for a single-occupancy bedroom or at least 80 square feet per resident in bedrooms occupied by more than one resident.—
The facility failed to ensure the building structure was sheathed to provide a 20-minute fire resistance rating or was constructed to meet the construction requirements for a nursing home.—
The facility failed to ensure the building electrical system met the references codes and standards.—
The facility failed to obtain pressure tests of gas piping in the facility.—
The facility failed to provide hot water with a temperature between 100 and 120 degrees F for lavatories and bathing units.—
The facility failed to provide smoke detectors in the required locations.—
The facility failed to ensure all resident rooms open on an exit, corridor, living area, or public area and are arranged for convenient access to dining and recreation areas.—
The facility failed to ensure that there was at least one operable window in every bedroom, that the operable window opened to the outside, that the sill of the operable window was within 44 inches of the floor, and that the window could be opened from the inside by all residents who occupy the bedroom, without tools or special devices.—
The facility failed to provide a fire sprinkler system that met the referenced codes and standards.—
The facility failed to provide exhaust for odor-producing areas.—
The facility failed to correct a site or building condition that was a fire, health, or physical hazard.—
The facility failed to provide a fire alarm control panel visible to facility staff or monitored by devices carried by facility staff.—

Reflects the HHSC record as pulled September 11, 2026. A recent visit may not appear yet. This is the Texas state licensing record; it is not the federal nursing home survey and the two are never combined.