State assisted-living licensing record · Texas HHSC · record as pulled September 11, 2026· Not the federal nursing home survey

Sunrise Senior Living of Hillcrest

13001 Hillcrest Rd, Dallas, TX 75240 · Dallas County · 115 licensed beds

HHSC licence number 147287 · licensed through June 26, 2027 · first licensed September 2006

The licence

Licensed by HHSC · Assisted Living Facility, Type B · Limited Liability Company (LLC)

Certifications and programs, as listed by HHSC
Alzheimer's certification
Yes, through 6/26/2027
Alzheimer's unit capacity
43
Accepts Medicaid
No
18
Citations on file
Since September 2021
3
HHSC visits
1 routine inspection
16
Life safety and building
Life safety · physical plant · emergency

Position within Texas

18 citations — more than 95% of the 1,995 licensed assisted living facilities in Texas. Compared only within Texas: a citation from HHSC means what it means in Texas, and there is no national assisted living record to compare to. Counted over 5 years, which holds two or three routine inspections. How this is calculated

Not in this record

Scope and severity, and enforcement. HHSC rates each finding on a scope-and-severity scale but does not publish the rating per facility, and it records fines and enforcement actions separately; neither is republished here. What is here is unusual among states: HHSC inspects fire and life safety itself and publishes those findings per facility, so this record carries a real life safety section.

Get an email about Sunrise Senior Living of Hillcrest

One email when it happens, from the HHSC record as it is pulled each month. No account; stop it any time with one click.

Which alerts

This is the state licensing record, not the federal nursing home survey. Your address is used for these alerts and nothing else.

Life safety and building citations

The citations about the building itself — fire and life safety, physical plant and emergency management. Usually the maintenance side’s to fix.

How that compares

Citations on file over 5 years

Compared with the median licensed assisted living facility in Texas. Within-state only.

This facility18Texas median2
Citations on file over 5 years, compared
MeasureCitations
This facility18
Median facility in Texas2

Visit history

Citations at each HHSC visit
22025-04162025-11
Citations at each HHSC visit
VisitTypeCitations
April 24, 2025health inspection2
November 20, 2025life safety code inspection16
November 20, 2025comprehensive inspection0

What the citations cover

Citations by category (TagProof's grouping)
  • Life safety 12
  • Physical plant 4
  • Uncatalogued tags 1
  • Records and administration 1
Citations by category
CategoryCitations
Life safety12
Physical plant4
Uncatalogued tags1
Records and administration1

Every visit on file since September 2021

As published by HHSC, newest first, including visits that cited nothing. The wording is HHSC’s own.

November 20, 2025 — life safety code inspection, 16 citations

Citations from the life safety code inspection on November 20, 2025
What HHSC foundCorrected
The facility failed to provide smoke compartmentation where required.—
The facility failed to provide an approved outdoor area for the segregated unit.—
The facility failed to protect hazardous areas as required by the referenced codes and standards.—
The facility failed to check gas heating systems prior to the heating season and to maintain records of the those checks.—
The facility failed to ensure openings between floors were protected to prevent the spread of fire and smoke from one floor to another.—
The facility failed to keep walls and ceilings in good condition.—
The facility failed to ensure means of egress met the referenced codes and standards.—
The facility failed to ensure doors in the facility met the referenced codes and standards.—
The facility failed to ensure heating, ventilating and air-conditioning equipment met the referenced codes and standards.—
The facility failed to provide required emergency lighting.—
The facility failed to have and enforce a smoking policy.—
The facility failed to have a program to inspect, test, and maintain the fire sprinkler system and keep records of inspection, testing, and maintenance of the fire sprinkler system.—
The facility failed to have a program to inspect, test, and maintain the fire alarm system and keep records of inspection, testing, and maintenance of the fire alarm system.—
The facility failed to obtain an inspection by the fire marshal every year and to keep documentation showing the outcome of the last inspection.—
The facility failed to provide a fire sprinkler system that met the referenced codes and standards.—
The facility failed to protect cooking operations according to the Life Safety Code.—

November 20, 2025 — comprehensive inspection, nothing cited

April 24, 2025 — health inspection, 2 citations

Reflects the HHSC record as pulled September 11, 2026. A recent visit may not appear yet. This is the Texas state licensing record; it is not the federal nursing home survey and the two are never combined.