Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

CYPRESS VILLAGE

JACKSONVILLE, FL · 100 certified beds · Last Life Safety survey April 17, 2025

CMS Certification Number 105745 · first certified October 1991

Ownership

Operated by HEALTHPEAK PROPERTIES, INC. · For profit - Corporation

No change of ownership on CMS record since January 1, 2016, when the records begin.

9
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
0
Tags cited more than once
Across separate surveys
5
Inspection & testing records
Of the citations on file

Position within FL

9 citations — more than 65% of the 694 certified nursing homes in FL. Compared within FL rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 8 citations; the earlier surveys in the window averaged 0.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window is open now: July 2026 to March 2027. This facility’s last Life Safety survey was April 2025. Facilities in FL are typically surveyed 15–23 months after the last one (median 17), measured over 729 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about CYPRESS VILLAGE

One email when it happens. No account; stop it any time with one click.

Which alerts

Physical environment (health survey)

1 physical-environment citation on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 9 Life Safety citations above. The Physical Environment Index

  • F-0908 Keep all essential equipment working safely.

How that compares

Citations on file over three years

Compared with the median facility in FL, and nationally. Surveyors differ markedly between states, so the FL figure is the meaningful one.

This facility9FL median7National median11
Citations on file over three years, compared
MeasureCitations
This facility9
Median facility in FL7
Median facility nationally11

Survey history

Citations at each Life Safety survey
02021-0912023-0582025-04
Citations at each Life Safety survey
Survey dateCitations
September 10, 20210
May 25, 20231
April 17, 20258

Most-cited tags

Most-cited tags at this facility
K-02221K-09231K-07611K-03721K-09181K-03241K-09191K-09141
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.12025-04-17
K-0923Have proper medical gas storage and administration areas.12025-04-17
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.12025-04-17
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.12025-04-17
K-0918Have generator or other power source capable of supplying service within 10 seconds.12025-04-17
K-0324Provide properly protected cooking facilities.12025-04-17
K-0919Meet requirements for the use of electrical equipment.12023-05-25
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.12025-04-17

What the citations cover

Citations by CMS category
  • Gas, Vacuum, and Electrical Systems Deficiencies 5
  • Smoke Deficiencies 2
  • Egress Deficiencies 1
  • Miscellaneous Deficiencies 1
Citations by CMS category
CategoryCitations
Gas, Vacuum, and Electrical Systems Deficiencies5
Smoke Deficiencies2
Egress Deficiencies1
Miscellaneous Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

April 17, 2025 — 8 citations

Citations issued on April 17, 2025
TagWhat the surveyor checksStatus
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (May 17, 2025)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (May 17, 2025)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (May 17, 2025)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (May 17, 2025)
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.Deficient, Provider has date of correction (May 17, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (May 17, 2025)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (May 17, 2025)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (May 17, 2025)

May 25, 2023 — 1 citation

Citations issued on May 25, 2023
TagWhat the surveyor checksStatus
K-0919Meet requirements for the use of electrical equipment.Deficient, Provider has date of correction (June 25, 2023)