Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

LAKE WORTH REHABILITATION CENTER

LAKE WORTH, FL · 120 certified beds · Last Life Safety survey June 13, 2025

CMS Certification Number 105659 · first certified January 1989

Ownership

Operated by SOVEREIGN HEALTHCARE HOLDINGS · For profit - Corporation

No change of ownership on CMS record since January 1, 2016, when the records begin.

11
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
2
Tags cited more than once
Across separate surveys
9
Inspection & testing records
Of the citations on file

Position within FL

11 citations — more than 73% of the 694 certified nursing homes in FL. Compared within FL rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 6 citations; the earlier surveys in the window averaged 2.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window is open now: September 2026 to April 2027. This facility’s last Life Safety survey was June 2025. Facilities in FL are typically surveyed 15–23 months after the last one (median 17), measured over 729 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about LAKE WORTH REHABILITATION CENTER

One email when it happens. No account; stop it any time with one click.

Which alerts

2 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

4 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 11 Life Safety citations above. The Physical Environment Index

  • F-0925 Make sure there is a pest control program to prevent/deal with mice, insects, or other pests.
  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0908 Keep all essential equipment working safely.

How that compares

Citations on file over three years

Compared with the median facility in FL, and nationally. Surveyors differ markedly between states, so the FL figure is the meaningful one.

This facility11FL median7National median11
Citations on file over three years, compared
MeasureCitations
This facility11
Median facility in FL7
Median facility nationally11

Survey history

Citations at each Life Safety survey
42022-1012024-0362025-06
Citations at each Life Safety survey
Survey dateCitations
October 27, 20224
March 1, 20241
June 13, 20256

Most-cited tags

Most-cited tags at this facility
K-03452K-03242K-05211K-03721K-03531K-03551K-09181K-09211
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0345Have approved installation, maintenance and testing program for fire alarm systems.22025-06-13
K-0324Provide properly protected cooking facilities.22025-06-13
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.12022-10-27
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.12025-06-13
K-0353Inspect, test, and maintain automatic sprinkler systems.12025-06-13
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.12022-10-27
K-0918Have generator or other power source capable of supplying service within 10 seconds.12025-06-13
K-0921Ensure that testing and maintenance of electrical equipment is performed.12025-06-13

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 7
  • Gas, Vacuum, and Electrical Systems Deficiencies 3
  • Services Deficiencies 1
Citations by CMS category
CategoryCitations
Smoke Deficiencies7
Gas, Vacuum, and Electrical Systems Deficiencies3
Services Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

June 13, 2025 — 6 citations

Citations issued on June 13, 2025
TagWhat the surveyor checksStatus
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (June 27, 2025)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (June 27, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (June 27, 2025)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (June 27, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (June 27, 2025)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (June 27, 2025)

March 1, 2024 — 1 citation

Citations issued on March 1, 2024
TagWhat the surveyor checksStatus
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (March 29, 2024)

October 27, 2022 — 4 citations

Citations issued on October 27, 2022
TagWhat the surveyor checksStatus
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (November 25, 2022)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (November 25, 2022)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (November 25, 2022)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (November 25, 2022)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.