Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

GLADES HEALTH CARE CENTER

PAHOKEE, FL · 120 certified beds · Last Life Safety survey April 16, 2026

CMS Certification Number 106018 · first certified November 1999

Ownership

Independently operated (no chain recorded by CMS) · For profit - Limited Liability company

No change of ownership on CMS record since January 1, 2016, when the records begin.

23
Citations on file
CMS's current file
3
Life Safety surveys
CMS's current file
4
Tags cited more than once
Across separate surveys
15
Inspection & testing records
Of the citations on file

Position within FL

23 citations — more than 98% of the 694 certified nursing homes in FL. Compared within FL rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in CMS's current file.

The latest survey found 9 citations; the earlier surveys on file averaged 7. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens July 2027 — about 9 months from now. This facility’s last Life Safety survey was April 2026. Facilities in FL are typically surveyed 15–22 months after the last one (median 17), measured over 742 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to about three years in Virginia. How the window is measured

Get an email about GLADES HEALTH CARE CENTER

One email when it happens. No account; stop it any time with one click.

Which alerts

4 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities cited for sprinkler inspection and testing in CMS’s current file are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Emergency preparedness

1 of the 23 citations on file is Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

1 physical-environment citation on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 23 Life Safety citations above. The Physical Environment Index

  • F-0880 Provide and implement an infection prevention and control program.

How that compares

Citations in CMS's current file

Compared with the median facility in FL, and nationally. Surveyors differ markedly between states, so the FL figure is the meaningful one.

This facility23FL median7National median11
Citations in CMS's current file, compared
MeasureCitations
This facility23
Median facility in FL7
Median facility nationally11

Survey history

Citations at each Life Safety survey
82023-0962024-1292026-04
Citations at each Life Safety survey
Survey dateCitations
September 21, 20238
December 5, 20246
April 16, 20269

Most-cited tags

Most-cited tags at this facility
K-03453K-03533K-02912K-09182K-09201K-07611K-07411K-09231
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0345Have approved installation, maintenance and testing program for fire alarm systems.32026-04-16
K-0353Inspect, test, and maintain automatic sprinkler systems.32026-04-16
K-0291Install emergency lighting that can last at least 1 1/2 hours.22026-04-16
K-0918Have generator or other power source capable of supplying service within 10 seconds.22026-04-16
K-0920Ensure proper usage of power strips and extension cords.12024-12-05
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.12023-09-21
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.12023-09-21
K-0923Have proper medical gas storage and administration areas.12026-04-16

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 10
  • Gas, Vacuum, and Electrical Systems Deficiencies 6
  • Miscellaneous Deficiencies 3
  • Egress Deficiencies 3
  • Other 1
Citations by CMS category
CategoryCitations
Smoke Deficiencies10
Gas, Vacuum, and Electrical Systems Deficiencies6
Miscellaneous Deficiencies3
Egress Deficiencies3
Emergency Preparedness Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

April 16, 2026 — 9 citations

Citations issued on April 16, 2026
TagWhat the surveyor checksStatus
E-0004Develop and maintain an Emergency Preparedness Program (EP).Deficient, Provider has date of correction (July 15, 2026)
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (July 15, 2026)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (July 15, 2026)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (July 15, 2026)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (July 15, 2026)
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.Deficient, Provider has date of correction (July 15, 2026)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (July 15, 2026)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (July 15, 2026)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (July 15, 2026)

December 5, 2024 — 6 citations

Citations issued on December 5, 2024
TagWhat the surveyor checksStatus
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (December 26, 2024)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (December 26, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (December 26, 2024)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (December 26, 2024)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (December 26, 2024)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (December 26, 2024)

September 21, 2023 — 8 citations

Citations issued on September 21, 2023
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (October 5, 2023)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (October 3, 2023)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (October 19, 2023)
K-0351Install an approved automatic sprinkler system.Deficient, Provider has date of correction (October 19, 2023)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (October 19, 2023)
K-0371Have properly sized and located compartments to protect residents from smoke.Deficient, Provider has date of correction (October 6, 2023)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (October 6, 2023)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (October 19, 2023)

Reflects the CMS posting of October 1, 2026. Surveys conducted in the last few months may not appear yet.