Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record
Williamsburg Health & Rehabilitation Center
Williamsburg, KY · 125 certified beds · Last Life Safety survey December 10, 2025
CMS Certification Number 185148 · first certified April 1978
Ownership
Operated by SEKY HOLDING CO. · For profit - Individual
No change of ownership on CMS record since January 1, 2016, when the records begin.
Position within KY
6 citations — more than 33% of the 266 certified nursing homes in KY. Compared within KY rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated
The latest survey found 2 citations; the earlier surveys on file averaged 2. With 3 surveys on file this is a direction of travel, not a conclusion.
When is the next survey likely?
The window opens January 2027 — about 2 months from now. This facility’s last Life Safety survey was December 2025. Facilities in KY are typically surveyed 13–49 months after the last one (median 16), measured over 414 consecutive surveys in the last two years of CMS records.
A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to about three years in Virginia. How the window is measured
Get an email about Williamsburg Health & Rehabilitation Center
One email when it happens. No account; stop it any time with one click.
Physical environment (health survey)
1 physical-environment citation on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 6 Life Safety citations above. The Physical Environment Index
- F-0880 Provide and implement an infection prevention and control program.
How that compares
Compared with the median facility in KY, and nationally. Surveyors differ markedly between states, so the KY figure is the meaningful one.
| Measure | Citations |
|---|---|
| This facility | 6 |
| Median facility in KY | 8 |
| Median facility nationally | 11 |
Survey history
| Survey date | Citations |
|---|---|
| July 18, 2019 | 0 |
| October 24, 2024 | 4 |
| December 10, 2025 | 2 |
Most-cited tags
| Tag | What the surveyor checks | Times cited | Last cited |
|---|---|---|---|
| K-0281 | Install proper backup exit lighting. | 1 | 2024-10-24 |
| K-0345 | Have approved installation, maintenance and testing program for fire alarm systems. | 1 | 2024-10-24 |
| K-0351 | Install an approved automatic sprinkler system. | 1 | 2024-10-24 |
| K-0363 | Install corridor and hallway doors that block smoke. | 1 | 2024-10-24 |
| K-0353 | Inspect, test, and maintain automatic sprinkler systems. | 1 | 2025-12-10 |
| K-0920 | Ensure proper usage of power strips and extension cords. | 1 | 2025-12-10 |
What the citations cover
- Smoke Deficiencies 4
- Egress Deficiencies 1
- Gas, Vacuum, and Electrical Systems Deficiencies 1
| Category | Citations |
|---|---|
| Smoke Deficiencies | 4 |
| Egress Deficiencies | 1 |
| Gas, Vacuum, and Electrical Systems Deficiencies | 1 |
Every citation on file
As published by CMS, newest survey first. Descriptions are CMS’s own wording.
December 10, 2025 — 2 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| K-0353 | Inspect, test, and maintain automatic sprinkler systems. | Deficient, Provider has date of correction (January 7, 2026) |
| K-0920 | Ensure proper usage of power strips and extension cords. | Deficient, Provider has date of correction (January 7, 2026) |
October 24, 2024 — 4 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| K-0281 | Install proper backup exit lighting. | Deficient, Provider has date of correction (November 20, 2024) |
| K-0345 | Have approved installation, maintenance and testing program for fire alarm systems. | Deficient, Provider has date of correction (November 20, 2024) |
| K-0351 | Install an approved automatic sprinkler system. | Deficient, Provider has date of correction (December 31, 2024) |
| K-0363 | Install corridor and hallway doors that block smoke. | Deficient, Provider has date of correction (November 20, 2024) |
Reflects the CMS posting of October 1, 2026. Surveys conducted in the last few months may not appear yet.