Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

PINNACLE HEALTH & REHAB AT SANFORD

SANFORD, ME · 86 certified beds · Last Life Safety survey February 26, 2025

CMS Certification Number 205082 · first certified January 1993

Ownership

Independently operated (no chain recorded by CMS) · For profit - Corporation

No change of ownership on CMS record since January 1, 2016, when the records begin.

25
Citations on file
Rolling three-year window
4
Life Safety surveys
In the same window
7
Tags cited more than once
Across separate surveys
12
Inspection & testing records
Of the citations on file

Position within ME

25 citations — more than 79% of the 78 certified nursing homes in ME. Compared within ME rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 2 citations; the earlier surveys in the window averaged 7.7. With 4 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

Past the typical window (March 2026 to May 2026). Most ME facilities have been surveyed by August 2027. This facility’s last Life Safety survey was February 2025. Facilities in ME are typically surveyed 13–15 months after the last one (median 14), measured over 115 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about PINNACLE HEALTH & REHAB AT SANFORD

One email when it happens. No account; stop it any time with one click.

Which alerts

3 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

4 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 25 Life Safety citations above. The Physical Environment Index

  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0880 Provide and implement an infection prevention and control program.

How that compares

Citations on file over three years

Compared with the median facility in ME, and nationally. Surveyors differ markedly between states, so the ME figure is the meaningful one.

This facility25ME median17National median11
Citations on file over three years, compared
MeasureCitations
This facility25
Median facility in ME17
Median facility nationally11

Survey history

Citations at each Life Safety survey
32022-0392023-11112025-0222025-02
Citations at each Life Safety survey
Survey dateCitations
March 2, 20223
November 15, 20239
February 12, 202511
February 26, 20252

Most-cited tags

Most-cited tags at this facility
K-03633K-03532K-02112K-03212K-09112K-03242K-09142K-02221
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0363Install corridor and hallway doors that block smoke.32025-02-12
K-0353Inspect, test, and maintain automatic sprinkler systems.22025-02-12
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.22025-02-12
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.22023-11-15
K-0911Meet requirements for the installation and maintenance of electrical systems.22025-02-26
K-0324Provide properly protected cooking facilities.22025-02-12
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.22025-02-26
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.12025-02-12

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 12
  • Gas, Vacuum, and Electrical Systems Deficiencies 7
  • Miscellaneous Deficiencies 3
  • Egress Deficiencies 3
Citations by CMS category
CategoryCitations
Smoke Deficiencies12
Gas, Vacuum, and Electrical Systems Deficiencies7
Miscellaneous Deficiencies3
Egress Deficiencies3

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

February 26, 2025 — 2 citations

Citations issued on February 26, 2025
TagWhat the surveyor checksStatus
K-0911Meet requirements for the installation and maintenance of electrical systems.Deficient, Provider has date of correction (May 9, 2025)
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.Deficient, Provider has date of correction (May 9, 2025)

February 12, 2025 — 11 citations

Citations issued on February 12, 2025
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (February 28, 2025)
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (February 18, 2025)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (February 21, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (February 11, 2025)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (February 11, 2025)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (February 28, 2025)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (February 27, 2025)
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.Deficient, Provider has date of correction (February 28, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (February 27, 2025)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (February 20, 2025)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (February 20, 2025)

November 15, 2023 — 9 citations

Citations issued on November 15, 2023
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (January 3, 2024)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (January 8, 2024)
K-0331Construct fire resistant interior walls.Deficient, Provider has date of correction (January 3, 2024)
K-0351Install an approved automatic sprinkler system.Deficient, Provider has date of correction (January 3, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (January 3, 2024)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (January 3, 2024)
K-0751Have restrictions on the use of flammable curtains.Deficient, Provider has date of correction (January 3, 2024)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (January 3, 2024)
K-0911Meet requirements for the installation and maintenance of electrical systems.Deficient, Provider has date of correction (January 3, 2024)

March 2, 2022 — 3 citations

Citations issued on March 2, 2022
TagWhat the surveyor checksStatus
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (March 29, 2022)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (March 29, 2022)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (March 29, 2022)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.