Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record
Coos County Nursing Hospital
WEST STEWARTSTOWN, NH · 97 certified beds · Last Life Safety survey October 16, 2025
CMS Certification Number 30E076 · first certified January 1979
Ownership
Independently operated (no chain recorded by CMS) · Government - County
No change of ownership on CMS record since January 1, 2016, when the records begin.
Position within NH
6 citations — more than 31% of the 73 certified nursing homes in NH. Compared within NH rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated
The latest survey found 3 citations; the earlier surveys in the window averaged 1.5. With 3 surveys on file this is a direction of travel, not a conclusion.
When is the next survey likely?
The window opens October 2026. This facility’s last Life Safety survey was October 2025. Facilities in NH are typically surveyed 12–13 months after the last one (median 13), measured over 131 consecutive surveys in the last two years of CMS records.
A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured
Get an email about Coos County Nursing Hospital
One email when it happens. No account; stop it any time with one click.
How that compares
Compared with the median facility in NH, and nationally. Surveyors differ markedly between states, so the NH figure is the meaningful one.
| Measure | Citations |
|---|---|
| This facility | 6 |
| Median facility in NH | 7 |
| Median facility nationally | 11 |
Survey history
| Survey date | Citations |
|---|---|
| November 17, 2023 | 0 |
| December 5, 2024 | 3 |
| October 16, 2025 | 3 |
Most-cited tags
| Tag | What the surveyor checks | Times cited | Last cited |
|---|---|---|---|
| K-0321 | Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. | 1 | 2024-12-05 |
| K-0223 | Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector. | 1 | 2025-10-16 |
| K-0363 | Install corridor and hallway doors that block smoke. | 1 | 2024-12-05 |
| K-0913 | Ensure operating rooms are properly protected and written records are maintained and available for inspection. | 1 | 2025-10-16 |
| K-0914 | Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing. | 1 | 2025-10-16 |
| K-0918 | Have generator or other power source capable of supplying service within 10 seconds. | 1 | 2024-12-05 |
What the citations cover
- Gas, Vacuum, and Electrical Systems Deficiencies 3
- Smoke Deficiencies 2
- Egress Deficiencies 1
| Category | Citations |
|---|---|
| Gas, Vacuum, and Electrical Systems Deficiencies | 3 |
| Smoke Deficiencies | 2 |
| Egress Deficiencies | 1 |
Every citation on file
As published by CMS, newest survey first. Descriptions are CMS’s own wording.
October 16, 2025 — 3 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| K-0223 | Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector. | Deficient, Provider has date of correction (November 6, 2025) |
| K-0913 | Ensure operating rooms are properly protected and written records are maintained and available for inspection. | Deficient, Provider has date of correction (November 6, 2025) |
| K-0914 | Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing. | Deficient, Provider has date of correction (November 6, 2025) |
December 5, 2024 — 3 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| K-0321 | Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. | Deficient, Provider has date of correction (February 20, 2025) |
| K-0363 | Install corridor and hallway doors that block smoke. | Deficient, Provider has date of correction (February 20, 2025) |
| K-0918 | Have generator or other power source capable of supplying service within 10 seconds. | Deficient, Provider has date of correction (February 20, 2025) |
Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.