Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

LAWRENCE REHABILITATION HOSPITAL

LAWRENCEVILLE, NJ · 56 certified beds · Last Life Safety survey January 30, 2026

CMS Certification Number 315127 · first certified June 1971

Ownership

Operated by MARQUIS HEALTH SERVICES · For profit - Limited Liability company

  • Ownership changed February 1, 2023 (change of ownership)from MORRIS HALL ST LAWRENCE INC
18
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
3
Tags cited more than once
Across separate surveys
12
Inspection & testing records
Of the citations on file

Position within NJ

18 citations — more than 63% of the 348 certified nursing homes in NJ. Compared within NJ rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 7 citations; the earlier surveys in the window averaged 5.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens May 2027 — about 8 months from now. This facility’s last Life Safety survey was January 2026. Facilities in NJ are typically surveyed 16–20 months after the last one (median 17), measured over 431 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about LAWRENCE REHABILITATION HOSPITAL

One email when it happens. No account; stop it any time with one click.

Which alerts

3 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

4 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 18 Life Safety citations above. The Physical Environment Index

  • F-0880 Provide and implement an infection prevention and control program.
  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.

How that compares

Citations on file over three years

Compared with the median facility in NJ, and nationally. Surveyors differ markedly between states, so the NJ figure is the meaningful one.

This facility18NJ median15National median11
Citations on file over three years, compared
MeasureCitations
This facility18
Median facility in NJ15
Median facility nationally11

Survey history

Citations at each Life Safety survey
32023-0682024-0972026-01
Citations at each Life Safety survey
Survey dateCitations
June 2, 20233
September 6, 20248
January 30, 20267

Most-cited tags

Most-cited tags at this facility
K-03532K-07612K-03632K-09181K-02251K-03721K-09141K-02111
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0353Inspect, test, and maintain automatic sprinkler systems.22026-01-30
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.22026-01-30
K-0363Install corridor and hallway doors that block smoke.22026-01-30
K-0918Have generator or other power source capable of supplying service within 10 seconds.12024-09-06
K-0225Have stairways and smokeproof enclosures used as exits that meet safety requirements.12024-09-06
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.12026-01-30
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.12024-09-06
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.12026-01-30

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 8
  • Egress Deficiencies 3
  • Gas, Vacuum, and Electrical Systems Deficiencies 3
  • Miscellaneous Deficiencies 2
  • Other 2
Citations by CMS category
CategoryCitations
Smoke Deficiencies8
Egress Deficiencies3
Gas, Vacuum, and Electrical Systems Deficiencies3
Miscellaneous Deficiencies2
Services Deficiencies2

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

January 30, 2026 — 7 citations

Citations issued on January 30, 2026
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (March 2, 2026)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (March 2, 2026)
K-0352Properly install and monitor supervisory attachments on automatic sprinkler systems.Deficient, Provider has date of correction (March 2, 2026)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (March 13, 2026)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (March 2, 2026)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (March 2, 2026)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (March 2, 2026)

September 6, 2024 — 8 citations

Citations issued on September 6, 2024
TagWhat the surveyor checksStatus
K-0225Have stairways and smokeproof enclosures used as exits that meet safety requirements.Deficient, Provider has date of correction (October 13, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (October 21, 2024)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (September 7, 2024)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (November 4, 2024)
K-0531Have elevators that firefighters can control in the event of a fire.Deficient, Provider has date of correction (November 8, 2024)
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.Deficient, Provider has date of correction (October 13, 2024)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (October 13, 2024)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (September 11, 2024)

June 2, 2023 — 3 citations

Citations issued on June 2, 2023
TagWhat the surveyor checksStatus
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (June 15, 2023)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (July 14, 2023)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (June 15, 2023)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.