Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

COMPLETE CARE AT MADISON, LLC

MATAWAN, NJ · 167 certified beds · Last Life Safety survey March 3, 2026

CMS Certification Number 315015 · first certified January 1967

Ownership

Operated by COMPLETE CARE · For profit - Limited Liability company

  • Ownership changed July 1, 2021 (change of ownership)from 625 STATE HIGHWAY 34 OPERATIONS LLC
27
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
5
Tags cited more than once
Across separate surveys
13
Inspection & testing records
Of the citations on file

Position within NJ

27 citations — more than 89% of the 348 certified nursing homes in NJ. Compared within NJ rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 7 citations; the earlier surveys in the window averaged 10. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens June 2027 — about 9 months from now. This facility’s last Life Safety survey was March 2026. Facilities in NJ are typically surveyed 16–20 months after the last one (median 17), measured over 431 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about COMPLETE CARE AT MADISON, LLC

One email when it happens. No account; stop it any time with one click.

Which alerts

2 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

2 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 27 Life Safety citations above. The Physical Environment Index

  • F-0880 Provide and implement an infection prevention and control program.
  • F-0919 Make sure that a working call system is available in each resident's bathroom and bathing area.

How that compares

Citations on file over three years

Compared with the median facility in NJ, and nationally. Surveyors differ markedly between states, so the NJ figure is the meaningful one.

This facility27NJ median15National median11
Citations on file over three years, compared
MeasureCitations
This facility27
Median facility in NJ15
Median facility nationally11

Survey history

Citations at each Life Safety survey
92022-12112024-0872026-03
Citations at each Life Safety survey
Survey dateCitations
December 9, 20229
August 27, 202411
March 3, 20267

Most-cited tags

Most-cited tags at this facility
K-03533K-03213K-02933K-05212K-03742K-03631K-09111K-07411
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0353Inspect, test, and maintain automatic sprinkler systems.32026-03-03
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.32026-03-03
K-0293Have properly located and lighted "Exit" signs.32026-03-03
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.22026-03-03
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.22026-03-03
K-0363Install corridor and hallway doors that block smoke.12022-12-09
K-0911Meet requirements for the installation and maintenance of electrical systems.12026-03-03
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.12024-08-27

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 14
  • Egress Deficiencies 7
  • Miscellaneous Deficiencies 2
  • Services Deficiencies 2
  • Other 2
Citations by CMS category
CategoryCitations
Smoke Deficiencies14
Egress Deficiencies7
Miscellaneous Deficiencies2
Services Deficiencies2
Gas, Vacuum, and Electrical Systems Deficiencies2

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

March 3, 2026 — 7 citations

Citations issued on March 3, 2026
TagWhat the surveyor checksStatus
K-0293Have properly located and lighted "Exit" signs.Deficient, Provider has date of correction (April 3, 2026)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (March 27, 2026)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (March 27, 2026)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (March 30, 2026)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (April 9, 2026)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (March 27, 2026)
K-0911Meet requirements for the installation and maintenance of electrical systems.Deficient, Provider has date of correction (March 27, 2026)

August 27, 2024 — 11 citations

Citations issued on August 27, 2024
TagWhat the surveyor checksStatus
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (September 16, 2024)
K-0223Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.Deficient, Provider has date of correction (September 19, 2024)
K-0293Have properly located and lighted "Exit" signs.Deficient, Provider has date of correction (September 19, 2024)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (September 19, 2024)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (September 19, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (September 19, 2024)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (September 19, 2024)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (September 19, 2024)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (September 19, 2024)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (September 19, 2024)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (September 19, 2024)

December 9, 2022 — 9 citations

Citations issued on December 9, 2022
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (January 2, 2023)
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (January 20, 2023)
K-0293Have properly located and lighted "Exit" signs.Deficient, Provider has date of correction (January 6, 2023)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (January 6, 2023)
K-0341Install a fire alarm system that can be heard throughout the facility.Deficient, Provider has date of correction (January 31, 2023)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (January 6, 2023)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (March 8, 2023)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (February 1, 2023)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (February 24, 2023)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.