Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record
ARBOR RIDGE REHABILITATION AND HEALTHCARE CENTER
WAYNE, NJ · 120 certified beds · Last Life Safety survey June 5, 2026
CMS Certification Number 315234 · first certified September 1986
Ownership
Operated by MARQUIS HEALTH SERVICES · For profit - Individual
- Ownership changed December 4, 2019 (change of ownership)from 261 TERHUNE DRIVE OPERATIONS LLC
Position within NJ
15 citations — more than 46% of the 348 certified nursing homes in NJ. Compared within NJ rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated
The latest survey found 2 citations; the earlier surveys on file averaged 6.5. With 3 surveys on file this is a direction of travel, not a conclusion.
When is the next survey likely?
The window opens October 2027 — about 11 months from now. This facility’s last Life Safety survey was June 2026. Facilities in NJ are typically surveyed 16–19 months after the last one (median 17), measured over 464 consecutive surveys in the last two years of CMS records.
A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to about three years in Virginia. How the window is measured
Get an email about ARBOR RIDGE REHABILITATION AND HEALTHCARE CENTER
One email when it happens. No account; stop it any time with one click.
2 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities cited for sprinkler inspection and testing in CMS’s current file are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.
Physical environment (health survey)
1 physical-environment citation on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 15 Life Safety citations above. The Physical Environment Index
- F-0880 Provide and implement an infection prevention and control program.
How that compares
Compared with the median facility in NJ, and nationally. Surveyors differ markedly between states, so the NJ figure is the meaningful one.
| Measure | Citations |
|---|---|
| This facility | 15 |
| Median facility in NJ | 15 |
| Median facility nationally | 11 |
Survey history
| Survey date | Citations |
|---|---|
| November 23, 2022 | 8 |
| October 17, 2024 | 5 |
| June 5, 2026 | 2 |
Most-cited tags
| Tag | What the surveyor checks | Times cited | Last cited |
|---|---|---|---|
| K-0372 | Ensure smoke barriers are constructed to a 1 hour fire resistance rating. | 2 | 2024-10-17 |
| K-0355 | Properly select, install, inspect, or maintain portable fire extinguishes. | 2 | 2026-06-05 |
| K-0345 | Have approved installation, maintenance and testing program for fire alarm systems. | 1 | 2024-10-17 |
| K-0351 | Install an approved automatic sprinkler system. | 1 | 2022-11-23 |
| K-0761 | To conduct inspection, testing and maintenance of fire doors by qualified individuals. | 1 | 2024-10-17 |
| K-0200 | Meet other general requirements. | 1 | 2024-10-17 |
| K-0911 | Meet requirements for the installation and maintenance of electrical systems. | 1 | 2022-11-23 |
| K-0324 | Provide properly protected cooking facilities. | 1 | 2022-11-23 |
What the citations cover
- Smoke Deficiencies 9
- Egress Deficiencies 3
- Miscellaneous Deficiencies 2
- Gas, Vacuum, and Electrical Systems Deficiencies 1
| Category | Citations |
|---|---|
| Smoke Deficiencies | 9 |
| Egress Deficiencies | 3 |
| Miscellaneous Deficiencies | 2 |
| Gas, Vacuum, and Electrical Systems Deficiencies | 1 |
Every citation on file
As published by CMS, newest survey first. Descriptions are CMS’s own wording.
June 5, 2026 — 2 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| K-0355 | Properly select, install, inspect, or maintain portable fire extinguishes. | Deficient, Provider has date of correction (July 7, 2026) |
| K-0712 | Have simulated fire drills held at unexpected times. | Deficient, Provider has date of correction (July 7, 2026) |
October 17, 2024 — 5 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| K-0200 | Meet other general requirements. | Deficient, Provider has date of correction (November 15, 2024) |
| K-0311 | Have an enclosure around a vertical opening shaft. | Deficient, Provider has date of correction (November 15, 2024) |
| K-0345 | Have approved installation, maintenance and testing program for fire alarm systems. | Deficient, Provider has date of correction (November 8, 2024) |
| K-0372 | Ensure smoke barriers are constructed to a 1 hour fire resistance rating. | Deficient, Provider has date of correction (November 15, 2024) |
| K-0761 | To conduct inspection, testing and maintenance of fire doors by qualified individuals. | Deficient, Provider has date of correction (November 8, 2024) |
November 23, 2022 — 8 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| K-0222 | Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements. | Deficient, Provider has date of correction (December 19, 2022) |
| K-0281 | Install proper backup exit lighting. | Deficient, Provider has date of correction (January 23, 2023) |
| K-0321 | Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. | Deficient, Provider has date of correction (January 23, 2023) |
| K-0324 | Provide properly protected cooking facilities. | Deficient, Provider has date of correction (January 23, 2023) |
| K-0351 | Install an approved automatic sprinkler system. | Deficient, Provider has date of correction (January 23, 2023) |
| K-0355 | Properly select, install, inspect, or maintain portable fire extinguishes. | Deficient, Provider has date of correction (January 23, 2023) |
| K-0372 | Ensure smoke barriers are constructed to a 1 hour fire resistance rating. | Deficient, Provider has date of correction (January 23, 2023) |
| K-0911 | Meet requirements for the installation and maintenance of electrical systems. | Deficient, Provider has date of correction (January 23, 2023) |
Reflects the CMS posting of October 1, 2026. Surveys conducted in the last few months may not appear yet.