Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record
OTTAWA CO RIVERVIEW NURSING HO
OAK HARBOR, OH · 115 certified beds · Last Life Safety survey February 26, 2026
CMS Certification Number 365498 · first certified June 1980
Ownership
Independently operated (no chain recorded by CMS) · Government - County
No change of ownership on CMS record since January 1, 2016, when the records begin.
Position within OH
27 citations — more than 81% of the 922 certified nursing homes in OH. Compared within OH rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated
The latest survey found 16 citations; the earlier surveys in the window averaged 5.5. With 3 surveys on file this is a direction of travel, not a conclusion.
When is the next survey likely?
The window opens October 2027 — about 13 months from now. This facility’s last Life Safety survey was February 2026. Facilities in OH are typically surveyed 20–32 months after the last one (median 26), measured over 889 consecutive surveys in the last two years of CMS records.
A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured
Get an email about OTTAWA CO RIVERVIEW NURSING HO
One email when it happens. No account; stop it any time with one click.
3 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.
Emergency preparedness
2 of the 27 citations on file are Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index
How that compares
Compared with the median facility in OH, and nationally. Surveyors differ markedly between states, so the OH figure is the meaningful one.
| Measure | Citations |
|---|---|
| This facility | 27 |
| Median facility in OH | 16 |
| Median facility nationally | 11 |
Survey history
| Survey date | Citations |
|---|---|
| January 23, 2020 | 4 |
| May 18, 2023 | 7 |
| February 26, 2026 | 16 |
Most-cited tags
| Tag | What the surveyor checks | Times cited | Last cited |
|---|---|---|---|
| K-0711 | Provide a written emergency evacuation plan. | 2 | 2026-02-26 |
| K-0351 | Install an approved automatic sprinkler system. | 2 | 2026-02-26 |
| K-0363 | Install corridor and hallway doors that block smoke. | 2 | 2026-02-26 |
| K-0222 | Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements. | 2 | 2026-02-26 |
| K-0511 | Have properly installed electrical wiring and gas equipment. | 2 | 2026-02-26 |
| K-0345 | Have approved installation, maintenance and testing program for fire alarm systems. | 2 | 2026-02-26 |
| K-0324 | Provide properly protected cooking facilities. | 1 | 2023-05-18 |
| K-0331 | Construct fire resistant interior walls. | 1 | 2026-02-26 |
What the citations cover
- Smoke Deficiencies 11
- Egress Deficiencies 4
- Miscellaneous Deficiencies 4
- Gas, Vacuum, and Electrical Systems Deficiencies 2
- Other 6
| Category | Citations |
|---|---|
| Smoke Deficiencies | 11 |
| Egress Deficiencies | 4 |
| Miscellaneous Deficiencies | 4 |
| Gas, Vacuum, and Electrical Systems Deficiencies | 2 |
| Services Deficiencies | 2 |
| Emergency Preparedness Deficiencies | 2 |
| Construction Deficiencies | 2 |
Every citation on file
As published by CMS, newest survey first. Descriptions are CMS’s own wording.
February 26, 2026 — 16 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| E-0015 | Address subsistence needs for staff and patients. | Deficient, Provider has date of correction (April 17, 2026) |
| E-0025 | Create arrangements with other facilities to receive patients. | Deficient, Provider has date of correction (April 17, 2026) |
| K-0131 | Meet requirements for sections of health care facilities separated by fire resistive construction. | Deficient, Provider has date of correction (April 17, 2026) |
| K-0211 | Keep aisles, corridors, and exits free of obstruction in case of emergency. | Deficient, Provider has date of correction (April 17, 2026) |
| K-0222 | Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements. | Deficient, Provider has date of correction (April 17, 2026) |
| K-0293 | Have properly located and lighted "Exit" signs. | Deficient, Provider has date of correction (April 17, 2026) |
| K-0321 | Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. | Deficient, Provider has date of correction (April 17, 2026) |
| K-0331 | Construct fire resistant interior walls. | Deficient, Provider has date of correction (April 17, 2026) |
| K-0345 | Have approved installation, maintenance and testing program for fire alarm systems. | Deficient, Provider has date of correction (April 17, 2026) |
| K-0351 | Install an approved automatic sprinkler system. | Deficient, Provider has date of correction (April 17, 2026) |
| K-0353 | Inspect, test, and maintain automatic sprinkler systems. | Deficient, Provider has date of correction (April 17, 2026) |
| K-0363 | Install corridor and hallway doors that block smoke. | Deficient, Provider has date of correction (April 17, 2026) |
| K-0372 | Ensure smoke barriers are constructed to a 1 hour fire resistance rating. | Deficient, Provider has date of correction (April 17, 2026) |
| K-0511 | Have properly installed electrical wiring and gas equipment. | Deficient, Provider has date of correction (April 17, 2026) |
| K-0711 | Provide a written emergency evacuation plan. | Deficient, Provider has date of correction (April 17, 2026) |
| K-0741 | Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed. | Deficient, Provider has date of correction (April 17, 2026) |
May 18, 2023 — 7 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| K-0161 | Use approved construction type or materials. | Deficient, Provider has date of correction (July 6, 2023) |
| K-0222 | Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements. | Deficient, Provider has date of correction (July 6, 2023) |
| K-0324 | Provide properly protected cooking facilities. | Deficient, Provider has date of correction (July 6, 2023) |
| K-0345 | Have approved installation, maintenance and testing program for fire alarm systems. | Deficient, Provider has date of correction (July 6, 2023) |
| K-0351 | Install an approved automatic sprinkler system. | Deficient, Provider has date of correction (July 6, 2023) |
| K-0363 | Install corridor and hallway doors that block smoke. | Deficient, Provider has date of correction (July 6, 2023) |
| K-0711 | Provide a written emergency evacuation plan. | Deficient, Provider has date of correction (July 6, 2023) |
January 23, 2020 — 4 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| K-0511 | Have properly installed electrical wiring and gas equipment. | Deficient, Provider has date of correction (March 12, 2020) |
| K-0761 | To conduct inspection, testing and maintenance of fire doors by qualified individuals. | Deficient, Provider has date of correction (March 12, 2020) |
| K-0918 | Have generator or other power source capable of supplying service within 10 seconds. | Deficient, Provider has date of correction (March 12, 2020) |
| K-0923 | Have proper medical gas storage and administration areas. | Deficient, Provider has date of correction (March 12, 2020) |
Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.