Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

JEWEL HEALTHCARE AND REHABILITATION CENTER

ALLENTOWN, PA · 146 certified beds · Last Life Safety survey August 28, 2025

CMS Certification Number 395264 · first certified June 1969

Ownership

Independently operated (no chain recorded by CMS) · For profit - Partnership

No change of ownership on CMS record since January 1, 2016, when the records begin.

24
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
6
Tags cited more than once
Across separate surveys
10
Inspection & testing records
Of the citations on file

Position within PA

24 citations — more than 89% of the 656 certified nursing homes in PA. Compared within PA rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Holding steadyabout the same at the latest survey as at its earlier surveys in the window.

The latest survey found 8 citations; the earlier surveys in the window averaged 8. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

Well past the typical window (July 2026 to August 2026), and past the point by which nine in ten PA facilities have been surveyed. This facility’s last Life Safety survey was August 2025. Facilities in PA are typically surveyed 10–12 months after the last one (median 11), measured over 1,113 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about JEWEL HEALTHCARE AND REHABILITATION CENTER

One email when it happens. No account; stop it any time with one click.

Which alerts

3 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

3 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 24 Life Safety citations above. The Physical Environment Index

  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0921 Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public.

How that compares

Citations on file over three years

Compared with the median facility in PA, and nationally. Surveyors differ markedly between states, so the PA figure is the meaningful one.

This facility24PA median10National median11
Citations on file over three years, compared
MeasureCitations
This facility24
Median facility in PA10
Median facility nationally11

Survey history

Citations at each Life Safety survey
112023-0852024-0982025-08
Citations at each Life Safety survey
Survey dateCitations
August 31, 202311
September 12, 20245
August 28, 20258

Most-cited tags

Most-cited tags at this facility
K-03743K-03213K-03552K-03532K-01612K-03632K-03241K-09021
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.32025-08-28
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.32025-08-28
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.22025-08-28
K-0353Inspect, test, and maintain automatic sprinkler systems.22025-08-28
K-0161Use approved construction type or materials.22024-09-12
K-0363Install corridor and hallway doors that block smoke.22025-08-28
K-0324Provide properly protected cooking facilities.12023-08-31
K-0902Meet requirements for the installation and maintenance of medical gas and medical vacuum systems.12023-08-31

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 15
  • Egress Deficiencies 3
  • Construction Deficiencies 2
  • Gas, Vacuum, and Electrical Systems Deficiencies 2
  • Other 2
Citations by CMS category
CategoryCitations
Smoke Deficiencies15
Egress Deficiencies3
Construction Deficiencies2
Gas, Vacuum, and Electrical Systems Deficiencies2
Miscellaneous Deficiencies2

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

August 28, 2025 — 8 citations

Citations issued on August 28, 2025
TagWhat the surveyor checksStatus
K-0225Have stairways and smokeproof enclosures used as exits that meet safety requirements.Deficient, Provider has date of correction (September 25, 2025)
K-0293Have properly located and lighted "Exit" signs.Deficient, Provider has date of correction (September 25, 2025)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (September 25, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (September 25, 2025)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (September 25, 2025)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (September 25, 2025)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (September 25, 2025)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (September 25, 2025)

September 12, 2024 — 5 citations

Citations issued on September 12, 2024
TagWhat the surveyor checksStatus
K-0161Use approved construction type or materials.Deficient, Provider has date of correction (November 1, 2024)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (November 1, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (November 1, 2024)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (November 1, 2024)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (November 1, 2024)

August 31, 2023 — 11 citations

Citations issued on August 31, 2023
TagWhat the surveyor checksStatus
K-0161Use approved construction type or materials.Deficient, Provider has date of correction (September 23, 2023)
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (September 23, 2023)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (September 23, 2023)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (September 23, 2023)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (September 23, 2023)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (September 23, 2023)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (September 23, 2023)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (September 23, 2023)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (September 23, 2023)
K-0902Meet requirements for the installation and maintenance of medical gas and medical vacuum systems.Deficient, Provider has date of correction (September 23, 2023)
K-0911Meet requirements for the installation and maintenance of electrical systems.Deficient, Provider has date of correction (September 23, 2023)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.