Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

SANATOGA CENTER

POTTSTOWN, PA · 130 certified beds · Last Life Safety survey June 26, 2026

CMS Certification Number 395904 · first certified July 1993

Ownership

Operated by GENESIS HEALTHCARE · For profit - Partnership

No change of ownership on CMS record since January 1, 2016, when the records begin.

22
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
7
Tags cited more than once
Across separate surveys
17
Inspection & testing records
Of the citations on file

Position within PA

22 citations — more than 86% of the 656 certified nursing homes in PA. Compared within PA rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 3 citations; the earlier surveys in the window averaged 9.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens May 2027 — about 7 months from now. This facility’s last Life Safety survey was June 2026. Facilities in PA are typically surveyed 10–12 months after the last one (median 11), measured over 1,113 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about SANATOGA CENTER

One email when it happens. No account; stop it any time with one click.

Which alerts

5 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

1 physical-environment citation on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 22 Life Safety citations above. The Physical Environment Index

  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.

How that compares

Citations on file over three years

Compared with the median facility in PA, and nationally. Surveyors differ markedly between states, so the PA figure is the meaningful one.

This facility22PA median10National median11
Citations on file over three years, compared
MeasureCitations
This facility22
Median facility in PA10
Median facility nationally11

Survey history

Citations at each Life Safety survey
102024-0892025-0732026-06
Citations at each Life Safety survey
Survey dateCitations
August 16, 202410
July 25, 20259
June 26, 20263

Most-cited tags

Most-cited tags at this facility
K-05212K-03532K-01612K-07122K-09112K-03242K-09182K-03451
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.22025-07-25
K-0353Inspect, test, and maintain automatic sprinkler systems.22025-07-25
K-0161Use approved construction type or materials.22025-07-25
K-0712Have simulated fire drills held at unexpected times.22025-07-25
K-0911Meet requirements for the installation and maintenance of electrical systems.22025-07-25
K-0324Provide properly protected cooking facilities.22025-07-25
K-0918Have generator or other power source capable of supplying service within 10 seconds.22025-07-25
K-0345Have approved installation, maintenance and testing program for fire alarm systems.12025-07-25

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 9
  • Gas, Vacuum, and Electrical Systems Deficiencies 5
  • Miscellaneous Deficiencies 3
  • Construction Deficiencies 2
  • Other 3
Citations by CMS category
CategoryCitations
Smoke Deficiencies9
Gas, Vacuum, and Electrical Systems Deficiencies5
Miscellaneous Deficiencies3
Construction Deficiencies2
Services Deficiencies2
Egress Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

June 26, 2026 — 3 citations

Citations issued on June 26, 2026
TagWhat the surveyor checksStatus
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has plan of correction (August 11, 2026)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has plan of correction (August 11, 2026)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has plan of correction (August 11, 2026)

July 25, 2025 — 9 citations

Citations issued on July 25, 2025
TagWhat the surveyor checksStatus
K-0161Use approved construction type or materials.Deficient, Provider has date of correction (September 18, 2025)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (September 18, 2025)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (September 18, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (September 18, 2025)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (September 18, 2025)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (September 18, 2025)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (September 18, 2025)
K-0911Meet requirements for the installation and maintenance of electrical systems.Deficient, Provider has date of correction (September 18, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (September 18, 2025)

August 16, 2024 — 10 citations

Citations issued on August 16, 2024
TagWhat the surveyor checksStatus
K-0161Use approved construction type or materials.Deficient, Provider has date of correction (October 11, 2024)
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (November 14, 2024)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (November 14, 2024)
K-0325Have properly installed hallway dispensers for alcohol-based hand rub.Deficient, Provider has date of correction (October 11, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (November 14, 2024)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (November 14, 2024)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (October 11, 2024)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (November 14, 2024)
K-0911Meet requirements for the installation and maintenance of electrical systems.Deficient, Provider has date of correction (October 11, 2024)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (November 14, 2024)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.