Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

MIRACLE MILE HEALTHCARE CENTER, LLC

LOS ANGELES, CA · 120 certified beds · Last Life Safety survey March 20, 2026

CMS Certification Number 555139 · first certified December 1981

Ownership

Independently operated (no chain recorded by CMS) · For profit - Limited Liability company

  • Ownership changed February 1, 2020 (change of ownership)from BEVERLY WEST HEALTHCARE LLC
27
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
8
Tags cited more than once
Across separate surveys
16
Inspection & testing records
Of the citations on file

Position within CA

27 citations — more than 77% of the 1,165 certified nursing homes in CA. Compared within CA rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 11 citations; the earlier surveys in the window averaged 8. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens March 2027 — about 6 months from now. This facility’s last Life Safety survey was March 2026. Facilities in CA are typically surveyed 12–18 months after the last one (median 14), measured over 1,766 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about MIRACLE MILE HEALTHCARE CENTER, LLC

One email when it happens. No account; stop it any time with one click.

Which alerts

5 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

24 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 27 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0908 Keep all essential equipment working safely.
  • F-0921 Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public.
  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0919 Make sure that a working call system is available in each resident's bathroom and bathing area.

How that compares

Citations on file over three years

Compared with the median facility in CA, and nationally. Surveyors differ markedly between states, so the CA figure is the meaningful one.

This facility27CA median19National median11
Citations on file over three years, compared
MeasureCitations
This facility27
Median facility in CA19
Median facility nationally11

Survey history

Citations at each Life Safety survey
32023-12132025-01112026-03
Citations at each Life Safety survey
Survey dateCitations
December 14, 20233
January 5, 202513
March 20, 202611

Most-cited tags

Most-cited tags at this facility
K-03533K-07613K-03512K-02912K-03422K-03632K-09202K-03452
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0353Inspect, test, and maintain automatic sprinkler systems.32026-03-20
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.32026-03-20
K-0351Install an approved automatic sprinkler system.22026-03-20
K-0291Install emergency lighting that can last at least 1 1/2 hours.22026-03-20
K-0342Have a complete alarm system manually initiated and initiated by fire sprinkler system connection.22026-03-20
K-0363Install corridor and hallway doors that block smoke.22025-01-05
K-0920Ensure proper usage of power strips and extension cords.22026-03-20
K-0345Have approved installation, maintenance and testing program for fire alarm systems.22026-03-20

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 14
  • Egress Deficiencies 5
  • Miscellaneous Deficiencies 4
  • Gas, Vacuum, and Electrical Systems Deficiencies 3
  • Other 1
Citations by CMS category
CategoryCitations
Smoke Deficiencies14
Egress Deficiencies5
Miscellaneous Deficiencies4
Gas, Vacuum, and Electrical Systems Deficiencies3
Services Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

March 20, 2026 — 11 citations

Citations issued on March 20, 2026
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (April 23, 2026)
K-0223Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.Deficient, Provider has date of correction (April 23, 2026)
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (April 23, 2026)
K-0342Have a complete alarm system manually initiated and initiated by fire sprinkler system connection.Deficient, Provider has date of correction (April 23, 2026)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (April 23, 2026)
K-0351Install an approved automatic sprinkler system.Deficient, Provider has date of correction (April 23, 2026)
K-0352Properly install and monitor supervisory attachments on automatic sprinkler systems.Deficient, Provider has date of correction (April 23, 2026)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (April 23, 2026)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (April 23, 2026)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (April 23, 2026)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (April 23, 2026)

January 5, 2025 — 13 citations

Citations issued on January 5, 2025
TagWhat the surveyor checksStatus
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (January 31, 2025)
K-0293Have properly located and lighted "Exit" signs.Deficient, Provider has date of correction (January 31, 2025)
K-0342Have a complete alarm system manually initiated and initiated by fire sprinkler system connection.Deficient, Provider has date of correction (January 31, 2025)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (January 31, 2025)
K-0351Install an approved automatic sprinkler system.Deficient, Provider has date of correction (January 31, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (January 31, 2025)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (January 31, 2025)
K-0362Ensure that corridors are separated from use areas by walls constructed to limit the passage of smoke.Deficient, Provider has date of correction (January 31, 2025)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (January 31, 2025)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (January 31, 2025)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (January 31, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (January 31, 2025)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (January 31, 2025)

December 14, 2023 — 3 citations

Citations issued on December 14, 2023
TagWhat the surveyor checksStatus
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (January 13, 2024)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (January 13, 2024)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (January 13, 2024)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.