Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Villa Marin

SAN RAFAEL, CA · 31 certified beds · Last Life Safety survey August 6, 2026

CMS Certification Number 555227 · first certified July 1986

Also on this campus

The same campus holds a state-licensed assisted living facility, with its own state record on the Assisted Living Index: Villa Marin Ambulatory Care Unit (100 Thorndale Drive). Matched by the street address the two records share. The records are separate and are never added together.

Ownership

Independently operated (no chain recorded by CMS) · Non profit - Corporation

No change of ownership on CMS record since January 1, 2016, when the records begin.

22
Citations on file
CMS's current file
3
Life Safety surveys
CMS's current file
4
Tags cited more than once
Across separate surveys
12
Inspection & testing records
Of the citations on file

Position within CA

22 citations — more than 62% of the 1,165 certified nursing homes in CA. Compared within CA rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in CMS's current file.

The latest survey found 9 citations; the earlier surveys on file averaged 6.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens August 2027 — about 9 months from now. This facility’s last Life Safety survey was August 2026. Facilities in CA are typically surveyed 12–16 months after the last one (median 14), measured over 1,814 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to about three years in Virginia. How the window is measured

Get an email about Villa Marin

One email when it happens. No account; stop it any time with one click.

Which alerts

3 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities cited for sprinkler inspection and testing in CMS’s current file are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

5 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 22 Life Safety citations above. The Physical Environment Index

  • F-0880 Provide and implement an infection prevention and control program.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0909 Regularly inspect all bed frames, mattresses, and bed rails (if any) for safety; and all bed rails and mattresses must attach safely to the bed frame.

How that compares

Citations in CMS's current file

Compared with the median facility in CA, and nationally. Surveyors differ markedly between states, so the CA figure is the meaningful one.

This facility22CA median19National median11
Citations in CMS's current file, compared
MeasureCitations
This facility22
Median facility in CA19
Median facility nationally11

Survey history

Citations at each Life Safety survey
102023-0832025-1192026-08
Citations at each Life Safety survey
Survey dateCitations
August 18, 202310
November 18, 20253
August 6, 20269

Most-cited tags

Most-cited tags at this facility
K-03453K-09182K-03242K-09192K-03521K-05211K-03441K-03721
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0345Have approved installation, maintenance and testing program for fire alarm systems.32026-08-06
K-0918Have generator or other power source capable of supplying service within 10 seconds.22026-08-06
K-0324Provide properly protected cooking facilities.22026-08-06
K-0919Meet requirements for the use of electrical equipment.22026-08-06
K-0352Properly install and monitor supervisory attachments on automatic sprinkler systems.12023-08-18
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.12026-08-06
K-0344Have an alternate power supply for its alarm system.12023-08-18
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.12023-08-18

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 13
  • Gas, Vacuum, and Electrical Systems Deficiencies 4
  • Egress Deficiencies 2
  • Services Deficiencies 2
  • Other 1
Citations by CMS category
CategoryCitations
Smoke Deficiencies13
Gas, Vacuum, and Electrical Systems Deficiencies4
Egress Deficiencies2
Services Deficiencies2
Miscellaneous Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

August 6, 2026 — 9 citations

Citations issued on August 6, 2026
TagWhat the surveyor checksStatus
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (August 11, 2026)
K-0342Have a complete alarm system manually initiated and initiated by fire sprinkler system connection.Deficient, Provider has date of correction (August 24, 2026)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (August 11, 2026)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (August 14, 2026)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (August 24, 2026)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (August 18, 2026)
K-0711Provide a written emergency evacuation plan.Deficient, Provider has date of correction (August 19, 2026)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (August 24, 2026)
K-0919Meet requirements for the use of electrical equipment.Deficient, Provider has date of correction (August 17, 2026)

November 18, 2025 — 3 citations

Citations issued on November 18, 2025
TagWhat the surveyor checksStatus
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (October 24, 2025)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (October 24, 2025)
K-0919Meet requirements for the use of electrical equipment.Deficient, Provider has date of correction (October 24, 2025)

August 18, 2023 — 10 citations

Citations issued on August 18, 2023
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (September 28, 2023)
K-0293Have properly located and lighted "Exit" signs.Deficient, Provider has date of correction (September 28, 2023)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (September 28, 2023)
K-0344Have an alternate power supply for its alarm system.Deficient, Provider has date of correction (September 28, 2023)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (September 28, 2023)
K-0347Properly provide smoke detection systems in areas open to corridors.Deficient, Provider has date of correction (September 28, 2023)
K-0352Properly install and monitor supervisory attachments on automatic sprinkler systems.Deficient, Provider has date of correction (September 28, 2023)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (September 28, 2023)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (September 28, 2023)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (September 28, 2023)

Reflects the CMS posting of October 1, 2026. Surveys conducted in the last few months may not appear yet.