Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Buena Vista Care Center

Santa Barbara, CA · 150 certified beds · Last Life Safety survey April 10, 2026

CMS Certification Number 555394 · first certified November 1989

Ownership

Operated by COVENANT CARE · For profit - Limited Liability company

No change of ownership on CMS record since January 1, 2016, when the records begin.

20
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
5
Tags cited more than once
Across separate surveys
6
Inspection & testing records
Of the citations on file

Position within CA

20 citations — more than 51% of the 1,165 certified nursing homes in CA. Compared within CA rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 6 citations; the earlier surveys in the window averaged 7. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens April 2027 — about 7 months from now. This facility’s last Life Safety survey was April 2026. Facilities in CA are typically surveyed 12–18 months after the last one (median 14), measured over 1,766 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about Buena Vista Care Center

One email when it happens. No account; stop it any time with one click.

Which alerts

2 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

8 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 20 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0908 Keep all essential equipment working safely.
  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0921 Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0925 Make sure there is a pest control program to prevent/deal with mice, insects, or other pests.

How that compares

Citations on file over three years

Compared with the median facility in CA, and nationally. Surveyors differ markedly between states, so the CA figure is the meaningful one.

This facility20CA median19National median11
Citations on file over three years, compared
MeasureCitations
This facility20
Median facility in CA19
Median facility nationally11

Survey history

Citations at each Life Safety survey
32022-03112025-0162026-04
Citations at each Life Safety survey
Survey dateCitations
March 3, 20223
January 17, 202511
April 10, 20266

Most-cited tags

Most-cited tags at this facility
K-09203K-03213K-09182K-03532K-03472K-02231K-03541K-03511
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0920Ensure proper usage of power strips and extension cords.32026-04-10
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.32026-04-10
K-0918Have generator or other power source capable of supplying service within 10 seconds.22026-04-10
K-0353Inspect, test, and maintain automatic sprinkler systems.22025-01-17
K-0347Properly provide smoke detection systems in areas open to corridors.22026-04-10
K-0223Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.12025-01-17
K-0354Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours.12026-04-10
K-0351Install an approved automatic sprinkler system.12026-04-10

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 9
  • Gas, Vacuum, and Electrical Systems Deficiencies 6
  • Egress Deficiencies 3
  • Services Deficiencies 2
Citations by CMS category
CategoryCitations
Smoke Deficiencies9
Gas, Vacuum, and Electrical Systems Deficiencies6
Egress Deficiencies3
Services Deficiencies2

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

April 10, 2026 — 6 citations

Citations issued on April 10, 2026
TagWhat the surveyor checksStatus
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (May 11, 2026)
K-0347Properly provide smoke detection systems in areas open to corridors.Deficient, Provider has date of correction (May 11, 2026)
K-0351Install an approved automatic sprinkler system.Deficient, Provider has date of correction (May 11, 2026)
K-0354Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours.Deficient, Provider has date of correction (May 11, 2026)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (May 11, 2026)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (May 11, 2026)

January 17, 2025 — 11 citations

Citations issued on January 17, 2025
TagWhat the surveyor checksStatus
K-0223Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.Deficient, Provider has date of correction (February 16, 2025)
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (February 16, 2025)
K-0293Have properly located and lighted "Exit" signs.Deficient, Provider has date of correction (February 16, 2025)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (February 16, 2025)
K-0347Properly provide smoke detection systems in areas open to corridors.Deficient, Provider has date of correction (February 16, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (February 16, 2025)
K-0500Meet other general requirements that are deficient.Deficient, Provider has date of correction (February 16, 2025)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (February 16, 2025)
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.Deficient, Provider has date of correction (February 16, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (February 16, 2025)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (February 16, 2025)

March 3, 2022 — 3 citations

Citations issued on March 3, 2022
TagWhat the surveyor checksStatus
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (March 16, 2022)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (March 16, 2022)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (March 16, 2022)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.