Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

ARBOR VIEW CARE CENTER, LLC

ARVADA, CO · 110 certified beds · Last Life Safety survey July 30, 2024

CMS Certification Number 065330 · first certified September 1994

Ownership

Operated by LONG PEAK OPERATING COMPANY · For profit - Corporation

  • Ownership changed July 1, 2024 (change of ownership)from HACKBERRY HILL OPCO LLC
13
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
1
Tags cited more than once
Across separate surveys
7
Inspection & testing records
Of the citations on file

Position within CO

13 citations — more than 36% of the 210 certified nursing homes in CO. Compared within CO rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 12 citations; the earlier surveys in the window averaged 0.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

Well past the typical window (January 2026 to August 2026), and past the point by which nine in ten CO facilities have been surveyed. This facility’s last Life Safety survey was July 2024. Facilities in CO are typically surveyed 17–24 months after the last one (median 19), measured over 177 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about ARBOR VIEW CARE CENTER, LLC

One email when it happens. No account; stop it any time with one click.

Which alerts

1 inspection-and-testing tag has been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

1 physical-environment citation on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 13 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.

How that compares

Citations on file over three years

Compared with the median facility in CO, and nationally. Surveyors differ markedly between states, so the CO figure is the meaningful one.

This facility13CO median16National median11
Citations on file over three years, compared
MeasureCitations
This facility13
Median facility in CO16
Median facility nationally11

Survey history

Citations at each Life Safety survey
02022-0112023-03122024-07
Citations at each Life Safety survey
Survey dateCitations
January 6, 20220
March 16, 20231
July 30, 202412

Most-cited tags

Most-cited tags at this facility
K-03532K-03451K-09201K-03461K-02811K-09231K-02221K-03631
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0353Inspect, test, and maintain automatic sprinkler systems.22024-07-30
K-0345Have approved installation, maintenance and testing program for fire alarm systems.12024-07-30
K-0920Ensure proper usage of power strips and extension cords.12024-07-30
K-0346Follow proper procedures when the fire alarm was out of service for more than 4 hours.12024-07-30
K-0281Install proper backup exit lighting.12024-07-30
K-0923Have proper medical gas storage and administration areas.12024-07-30
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.12024-07-30
K-0363Install corridor and hallway doors that block smoke.12024-07-30

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 8
  • Egress Deficiencies 3
  • Gas, Vacuum, and Electrical Systems Deficiencies 2
Citations by CMS category
CategoryCitations
Smoke Deficiencies8
Egress Deficiencies3
Gas, Vacuum, and Electrical Systems Deficiencies2

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

July 30, 2024 — 12 citations

Citations issued on July 30, 2024
TagWhat the surveyor checksStatus
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (September 25, 2024)
K-0231Provide large enough exits.Deficient, Provider has date of correction (September 25, 2024)
K-0281Install proper backup exit lighting.Deficient, Provider has date of correction (September 25, 2024)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (September 25, 2024)
K-0346Follow proper procedures when the fire alarm was out of service for more than 4 hours.Deficient, Provider has date of correction (September 25, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (September 25, 2024)
K-0354Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours.Deficient, Provider has date of correction (September 25, 2024)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (September 25, 2024)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (September 25, 2024)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (September 25, 2024)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (September 25, 2024)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (August 26, 2024)

March 16, 2023 — 1 citation

Citations issued on March 16, 2023
TagWhat the surveyor checksStatus
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (May 9, 2023)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.