Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

LAKEWOOD VILLA

LAKEWOOD, CO · 57 certified beds · Last Life Safety survey December 19, 2024

CMS Certification Number 065408 · first certified June 2013

Ownership

Operated by MADISON CREEK PARTNERS · For profit - Limited Liability company

No change of ownership on CMS record since January 1, 2016, when the records begin.

21
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
5
Tags cited more than once
Across separate surveys
15
Inspection & testing records
Of the citations on file

Position within CO

21 citations — more than 63% of the 210 certified nursing homes in CO. Compared within CO rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 10 citations; the earlier surveys in the window averaged 5.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window is open now: May 2026 to December 2026. This facility’s last Life Safety survey was December 2024. Facilities in CO are typically surveyed 17–24 months after the last one (median 19), measured over 177 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about LAKEWOOD VILLA

One email when it happens. No account; stop it any time with one click.

Which alerts

4 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

6 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 21 Life Safety citations above. The Physical Environment Index

  • F-0880 Provide and implement an infection prevention and control program.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0921 Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public.
  • F-0925 Make sure there is a pest control program to prevent/deal with mice, insects, or other pests.
  • F-0923 Have enough outside ventilation via a window or mechanical ventilation, or both.

How that compares

Citations on file over three years

Compared with the median facility in CO, and nationally. Surveyors differ markedly between states, so the CO figure is the meaningful one.

This facility21CO median16National median11
Citations on file over three years, compared
MeasureCitations
This facility21
Median facility in CO16
Median facility nationally11

Survey history

Citations at each Life Safety survey
52019-1062023-07102024-12
Citations at each Life Safety survey
Survey dateCitations
October 31, 20195
July 17, 20236
December 19, 202410

Most-cited tags

Most-cited tags at this facility
K-03633K-02913K-05212K-07122K-02112K-03531K-03551K-03451
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0363Install corridor and hallway doors that block smoke.32024-12-19
K-0291Install emergency lighting that can last at least 1 1/2 hours.32024-12-19
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.22024-12-19
K-0712Have simulated fire drills held at unexpected times.22024-12-19
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.22023-07-17
K-0353Inspect, test, and maintain automatic sprinkler systems.12024-12-19
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.12024-12-19
K-0345Have approved installation, maintenance and testing program for fire alarm systems.12019-10-31

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 7
  • Egress Deficiencies 6
  • Miscellaneous Deficiencies 3
  • Services Deficiencies 3
  • Other 2
Citations by CMS category
CategoryCitations
Smoke Deficiencies7
Egress Deficiencies6
Miscellaneous Deficiencies3
Services Deficiencies3
Gas, Vacuum, and Electrical Systems Deficiencies2

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

December 19, 2024 — 10 citations

Citations issued on December 19, 2024
TagWhat the surveyor checksStatus
K-0271Have exits that are accessible at all times.Deficient, Provider has date of correction (January 31, 2025)
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (January 13, 2025)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Waiver has been granted (February 23, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Waiver has been granted (April 12, 2025)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (January 24, 2025)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (February 7, 2025)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (January 30, 2025)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (February 5, 2025)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (January 24, 2025)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (January 23, 2025)

July 17, 2023 — 6 citations

Citations issued on July 17, 2023
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (October 3, 2023)
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (October 3, 2023)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (October 3, 2023)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (October 3, 2023)
K-0911Meet requirements for the installation and maintenance of electrical systems.Deficient, Provider has date of correction (October 3, 2023)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (October 3, 2023)

October 31, 2019 — 5 citations

Citations issued on October 31, 2019
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (December 3, 2019)
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (December 2, 2019)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (November 27, 2019)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (November 27, 2019)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (November 27, 2019)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.