Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

CIVITA CARE CENTER AT CHESHIRE

CHESHIRE, CT · 120 certified beds · Last Life Safety survey January 15, 2025

CMS Certification Number 075222 · first certified February 1973

Ownership

Operated by CIVITA CARE CENTERS · For profit - Limited Liability company

No change of ownership on CMS record since January 1, 2016, when the records begin.

20
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
2
Tags cited more than once
Across separate surveys
9
Inspection & testing records
Of the citations on file

Position within CT

20 citations — more than 80% of the 191 certified nursing homes in CT. Compared within CT rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 5 citations; the earlier surveys in the window averaged 7.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens October 2026 — about 1 month from now. This facility’s last Life Safety survey was January 2025. Facilities in CT are typically surveyed 21–28 months after the last one (median 24), measured over 181 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about CIVITA CARE CENTER AT CHESHIRE

One email when it happens. No account; stop it any time with one click.

Which alerts

1 inspection-and-testing tag has been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Emergency preparedness

2 of the 20 citations on file are Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

7 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 20 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0925 Make sure there is a pest control program to prevent/deal with mice, insects, or other pests.

How that compares

Citations on file over three years

Compared with the median facility in CT, and nationally. Surveyors differ markedly between states, so the CT figure is the meaningful one.

This facility20CT median10National median11
Citations on file over three years, compared
MeasureCitations
This facility20
Median facility in CT10
Median facility nationally11

Survey history

Citations at each Life Safety survey
62019-1292022-0952025-01
Citations at each Life Safety survey
Survey dateCitations
December 5, 20196
September 26, 20229
January 15, 20255

Most-cited tags

Most-cited tags at this facility
K-07613K-07112K-02221E-00391K-03241K-05211K-03451E-00361
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.32025-01-15
K-0711Provide a written emergency evacuation plan.22022-09-26
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.12025-01-15
E-0039Conduct testing and exercise requirements.12019-12-05
K-0324Provide properly protected cooking facilities.12022-09-26
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.12019-12-05
K-0345Have approved installation, maintenance and testing program for fire alarm systems.12022-09-26
E-0036Establish emergency prep training and testing.12019-12-05

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 8
  • Miscellaneous Deficiencies 5
  • Egress Deficiencies 3
  • Emergency Preparedness Deficiencies 2
  • Other 2
Citations by CMS category
CategoryCitations
Smoke Deficiencies8
Miscellaneous Deficiencies5
Egress Deficiencies3
Emergency Preparedness Deficiencies2
Gas, Vacuum, and Electrical Systems Deficiencies1
Services Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

January 15, 2025 — 5 citations

Citations issued on January 15, 2025
TagWhat the surveyor checksStatus
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (February 21, 2025)
K-0225Have stairways and smokeproof enclosures used as exits that meet safety requirements.Deficient, Provider has date of correction (April 8, 2025)
K-0351Install an approved automatic sprinkler system.Deficient, Provider has date of correction (January 22, 2025)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (January 22, 2025)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (April 8, 2025)

September 26, 2022 — 9 citations

Citations issued on September 26, 2022
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (October 28, 2022)
K-0311Have an enclosure around a vertical opening shaft.Deficient, Provider has date of correction (October 28, 2022)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (October 28, 2022)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (October 28, 2022)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (October 28, 2022)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (October 28, 2022)
K-0711Provide a written emergency evacuation plan.Deficient, Provider has date of correction (October 28, 2022)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (October 28, 2022)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (October 28, 2022)

December 5, 2019 — 6 citations

Citations issued on December 5, 2019
TagWhat the surveyor checksStatus
E-0036Establish emergency prep training and testing.Deficient, Provider has date of correction (January 23, 2020)
E-0039Conduct testing and exercise requirements.Deficient, Provider has date of correction (January 23, 2020)
K-0362Ensure that corridors are separated from use areas by walls constructed to limit the passage of smoke.Deficient, Provider has date of correction (January 23, 2020)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (January 23, 2020)
K-0711Provide a written emergency evacuation plan.Deficient, Provider has date of correction (January 23, 2020)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (January 23, 2020)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.