Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Cascades Health and Rehabilitation Center

DELRAY BEACH, FL · 100 certified beds · Last Life Safety survey December 4, 2025

CMS Certification Number 105335 · first certified October 1978

Ownership

Independently operated (no chain recorded by CMS) · For profit - Limited Liability company

No change of ownership on CMS record since January 1, 2016, when the records begin.

12
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
2
Tags cited more than once
Across separate surveys
9
Inspection & testing records
Of the citations on file

Position within FL

12 citations — more than 78% of the 694 certified nursing homes in FL. Compared within FL rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Holding steadyabout the same at the latest survey as at its earlier surveys in the window.

The latest survey found 4 citations; the earlier surveys in the window averaged 4. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens March 2027 — about 6 months from now. This facility’s last Life Safety survey was December 2025. Facilities in FL are typically surveyed 15–23 months after the last one (median 17), measured over 729 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about Cascades Health and Rehabilitation Center

One email when it happens. No account; stop it any time with one click.

Which alerts

2 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

7 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 12 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0919 Make sure that a working call system is available in each resident's bathroom and bathing area.
  • F-0924 Put firmly secured handrails on each side of hallways.

How that compares

Citations on file over three years

Compared with the median facility in FL, and nationally. Surveyors differ markedly between states, so the FL figure is the meaningful one.

This facility12FL median7National median11
Citations on file over three years, compared
MeasureCitations
This facility12
Median facility in FL7
Median facility nationally11

Survey history

Citations at each Life Safety survey
42023-0342024-0642025-12
Citations at each Life Safety survey
Survey dateCitations
March 17, 20234
June 6, 20244
December 4, 20254

Most-cited tags

Most-cited tags at this facility
K-03452K-03532K-02911K-05211K-02111K-09181K-02221K-03721
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0345Have approved installation, maintenance and testing program for fire alarm systems.22025-12-04
K-0353Inspect, test, and maintain automatic sprinkler systems.22024-06-06
K-0291Install emergency lighting that can last at least 1 1/2 hours.12023-03-17
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.12023-03-17
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.12024-06-06
K-0918Have generator or other power source capable of supplying service within 10 seconds.12025-12-04
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.12025-12-04
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.12023-03-17

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 6
  • Egress Deficiencies 3
  • Gas, Vacuum, and Electrical Systems Deficiencies 2
  • Services Deficiencies 1
Citations by CMS category
CategoryCitations
Smoke Deficiencies6
Egress Deficiencies3
Gas, Vacuum, and Electrical Systems Deficiencies2
Services Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

December 4, 2025 — 4 citations

Citations issued on December 4, 2025
TagWhat the surveyor checksStatus
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (January 9, 2026)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (January 9, 2026)
K-0917Ensure electrical receptacles or cover plates have distinctive color or marking.Deficient, Provider has date of correction (January 9, 2026)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (January 9, 2026)

June 6, 2024 — 4 citations

Citations issued on June 6, 2024
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (July 3, 2024)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (July 3, 2024)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (July 3, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (July 30, 2024)

March 17, 2023 — 4 citations

Citations issued on March 17, 2023
TagWhat the surveyor checksStatus
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (April 8, 2023)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (April 8, 2023)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (April 8, 2023)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (April 8, 2023)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.