Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

ELEVATE CARE NORTH BRANCH

NILES, IL · 212 certified beds · Last Life Safety survey April 18, 2025

CMS Certification Number 145630 · first certified August 1989

Ownership

Operated by ELEVATE CARE · For profit - Corporation

  • Ownership changed October 1, 2020 (change of ownership)from FOREST VILLA NURSING AND REHABILITATION CENTER, LLC
25
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
7
Tags cited more than once
Across separate surveys
13
Inspection & testing records
Of the citations on file

Position within IL

25 citations — more than 74% of the 666 certified nursing homes in IL. Compared within IL rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Holding steadyabout the same at the latest survey as at its earlier surveys in the window.

The latest survey found 8 citations; the earlier surveys in the window averaged 8.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

Well past the typical window (March 2026 to May 2026), and past the point by which nine in ten IL facilities have been surveyed. This facility’s last Life Safety survey was April 2025. Facilities in IL are typically surveyed 11–13 months after the last one (median 12), measured over 759 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about ELEVATE CARE NORTH BRANCH

One email when it happens. No account; stop it any time with one click.

Which alerts

5 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

11 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 25 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0908 Keep all essential equipment working safely.
  • F-0919 Make sure that a working call system is available in each resident's bathroom and bathing area.

How that compares

Citations on file over three years

Compared with the median facility in IL, and nationally. Surveyors differ markedly between states, so the IL figure is the meaningful one.

This facility25IL median15National median11
Citations on file over three years, compared
MeasureCitations
This facility25
Median facility in IL15
Median facility nationally11

Survey history

Citations at each Life Safety survey
102022-1272024-0482025-04
Citations at each Life Safety survey
Survey dateCitations
December 1, 202210
April 23, 20247
April 18, 20258

Most-cited tags

Most-cited tags at this facility
K-09182K-09232K-03742K-03722K-03632K-02712K-07122K-09141
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0918Have generator or other power source capable of supplying service within 10 seconds.22025-04-18
K-0923Have proper medical gas storage and administration areas.22024-04-23
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.22024-04-23
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.22025-04-18
K-0363Install corridor and hallway doors that block smoke.22024-04-23
K-0271Have exits that are accessible at all times.22025-04-18
K-0712Have simulated fire drills held at unexpected times.22025-04-18
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.12022-12-01

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 11
  • Gas, Vacuum, and Electrical Systems Deficiencies 7
  • Egress Deficiencies 3
  • Services Deficiencies 2
  • Other 2
Citations by CMS category
CategoryCitations
Smoke Deficiencies11
Gas, Vacuum, and Electrical Systems Deficiencies7
Egress Deficiencies3
Services Deficiencies2
Miscellaneous Deficiencies2

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

April 18, 2025 — 8 citations

Citations issued on April 18, 2025
TagWhat the surveyor checksStatus
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (May 2, 2025)
K-0271Have exits that are accessible at all times.Deficient, Provider has date of correction (May 2, 2025)
K-0341Install a fire alarm system that can be heard throughout the facility.Deficient, Provider has date of correction (May 2, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Waiver has been granted (May 15, 2025)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (May 2, 2025)
K-0531Have elevators that firefighters can control in the event of a fire.Deficient, Provider has date of correction (May 2, 2025)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (May 2, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (May 2, 2025)

April 23, 2024 — 7 citations

Citations issued on April 23, 2024
TagWhat the surveyor checksStatus
K-0271Have exits that are accessible at all times.Deficient, Provider has date of correction (May 2, 2024)
K-0311Have an enclosure around a vertical opening shaft.Deficient, Provider has date of correction (May 2, 2024)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (May 2, 2024)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (May 2, 2024)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (May 2, 2024)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (May 2, 2024)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (May 2, 2024)

December 1, 2022 — 10 citations

Citations issued on December 1, 2022
TagWhat the surveyor checksStatus
K-0362Ensure that corridors are separated from use areas by walls constructed to limit the passage of smoke.Deficient, Provider has date of correction (December 21, 2022)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (December 21, 2022)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (December 21, 2022)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (December 21, 2022)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (December 21, 2022)
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.Deficient, Provider has date of correction (December 21, 2022)
K-0915Have proper power supply for life support equipment.Deficient, Provider has date of correction (December 21, 2022)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (December 21, 2022)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (December 21, 2022)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (December 21, 2022)