ODIN HEALTH AND REHAB CENTER
ODIN, IL · 99 certified beds · Last Life Safety survey May 14, 2025
CMS Certification Number 145649 · first certified August 1989
Ownership
Operated by CREST HEALTHCARE CONSULTING · For profit - Corporation
- Ownership changed May 1, 2021 (change of ownership)from SSC ODIN OPERATING COMPANY LLC
Position within IL
41 citations — more than 94% of the 666 certified nursing homes in IL. Compared within IL rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated
The latest survey found 22 citations; the earlier surveys in the window averaged 9.5. With 3 surveys on file this is a direction of travel, not a conclusion.
When is the next survey likely?
Well past the typical window (April 2026 to June 2026), and past the point by which nine in ten IL facilities have been surveyed. This facility’s last Life Safety survey was May 2025. Facilities in IL are typically surveyed 11–13 months after the last one (median 12), measured over 759 consecutive surveys in the last two years of CMS records.
A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured
Get an email about ODIN HEALTH AND REHAB CENTER
One email when it happens. No account; stop it any time with one click.
3 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.
Emergency preparedness
14 of the 41 citations on file are Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index
Physical environment (health survey)
9 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 41 Life Safety citations above. The Physical Environment Index
- F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
- F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
- F-0880 Provide and implement an infection prevention and control program.
- F-0925 Make sure there is a pest control program to prevent/deal with mice, insects, or other pests.
How that compares
Compared with the median facility in IL, and nationally. Surveyors differ markedly between states, so the IL figure is the meaningful one.
| Measure | Citations |
|---|---|
| This facility | 41 |
| Median facility in IL | 15 |
| Median facility nationally | 11 |
Survey history
| Survey date | Citations |
|---|---|
| March 24, 2023 | 10 |
| June 28, 2024 | 9 |
| May 14, 2025 | 22 |
Most-cited tags
| Tag | What the surveyor checks | Times cited | Last cited |
|---|---|---|---|
| K-0712 | Have simulated fire drills held at unexpected times. | 3 | 2025-05-14 |
| E-0041 | Implement emergency and standby power systems. | 3 | 2025-05-14 |
| K-0920 | Ensure proper usage of power strips and extension cords. | 3 | 2025-05-14 |
| K-0353 | Inspect, test, and maintain automatic sprinkler systems. | 3 | 2025-05-14 |
| E-0039 | Conduct testing and exercise requirements. | 3 | 2025-05-14 |
| K-0918 | Have generator or other power source capable of supplying service within 10 seconds. | 2 | 2025-05-14 |
| E-0037 | Establish staff and initial training requirements. | 2 | 2025-05-14 |
| K-0374 | Install smoke barrier doors that can resist smoke for at least 20 minutes. | 1 | 2023-03-24 |
What the citations cover
- Emergency Preparedness Deficiencies 14
- Smoke Deficiencies 11
- Gas, Vacuum, and Electrical Systems Deficiencies 7
- Miscellaneous Deficiencies 4
- Other 5
| Category | Citations |
|---|---|
| Emergency Preparedness Deficiencies | 14 |
| Smoke Deficiencies | 11 |
| Gas, Vacuum, and Electrical Systems Deficiencies | 7 |
| Miscellaneous Deficiencies | 4 |
| Egress Deficiencies | 4 |
| Services Deficiencies | 1 |
Every citation on file
As published by CMS, newest survey first. Descriptions are CMS’s own wording.
May 14, 2025 — 22 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| E-0004 | Develop and maintain an Emergency Preparedness Program (EP). | Deficient, Provider has date of correction (June 10, 2025) |
| E-0007 | Address patient/client population and determine types of services needed. | Deficient, Provider has date of correction (June 11, 2025) |
| E-0025 | Create arrangements with other facilities to receive patients. | Deficient, Provider has date of correction (June 11, 2025) |
| E-0030 | List the names and contact information of those in the facility. | Deficient, Provider has date of correction (June 11, 2025) |
| E-0036 | Establish emergency prep training and testing. | Deficient, Provider has date of correction (June 11, 2025) |
| E-0037 | Establish staff and initial training requirements. | Deficient, Provider has date of correction (June 11, 2025) |
| E-0039 | Conduct testing and exercise requirements. | Deficient, Provider has date of correction (June 11, 2025) |
| E-0041 | Implement emergency and standby power systems. | Deficient, Provider has date of correction (June 11, 2025) |
| K-0291 | Install emergency lighting that can last at least 1 1/2 hours. | Deficient, Provider has date of correction (June 11, 2025) |
| K-0293 | Have properly located and lighted "Exit" signs. | Deficient, Provider has date of correction (June 11, 2025) |
| K-0324 | Provide properly protected cooking facilities. | Deficient, Provider has date of correction (June 11, 2025) |
| K-0345 | Have approved installation, maintenance and testing program for fire alarm systems. | Deficient, Provider has date of correction (June 11, 2025) |
| K-0346 | Follow proper procedures when the fire alarm was out of service for more than 4 hours. | Deficient, Provider has date of correction (June 11, 2025) |
| K-0351 | Install an approved automatic sprinkler system. | Deficient, Provider has date of correction (June 11, 2025) |
| K-0353 | Inspect, test, and maintain automatic sprinkler systems. | Deficient, Provider has date of correction (June 11, 2025) |
| K-0354 | Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours. | Deficient, Provider has date of correction (June 11, 2025) |
| K-0363 | Install corridor and hallway doors that block smoke. | Deficient, Provider has date of correction (June 11, 2025) |
| K-0712 | Have simulated fire drills held at unexpected times. | Deficient, Provider has date of correction (June 11, 2025) |
| K-0914 | Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing. | Deficient, Provider has date of correction (June 11, 2025) |
| K-0918 | Have generator or other power source capable of supplying service within 10 seconds. | Deficient, Provider has date of correction (June 11, 2025) |
| K-0920 | Ensure proper usage of power strips and extension cords. | Deficient, Provider has date of correction (June 11, 2025) |
| K-0927 | Have proper fire barriers, ventilation and signs for the transfilling of oxygen. | Deficient, Provider has date of correction (June 11, 2025) |
June 28, 2024 — 9 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| E-0015 | Address subsistence needs for staff and patients. | Deficient, Provider has date of correction (July 24, 2024) |
| E-0039 | Conduct testing and exercise requirements. | Deficient, Provider has date of correction (July 24, 2024) |
| E-0041 | Implement emergency and standby power systems. | Deficient, Provider has date of correction (July 24, 2024) |
| K-0211 | Keep aisles, corridors, and exits free of obstruction in case of emergency. | Deficient, Provider has date of correction (July 24, 2024) |
| K-0353 | Inspect, test, and maintain automatic sprinkler systems. | Deficient, Provider has date of correction (July 24, 2024) |
| K-0361 | Ensure that waiting areas, nurse’s stations, gift shops, and cooking facilities, open to the corridor are properly protected. | Deficient, Provider has date of correction (September 1, 2024) |
| K-0712 | Have simulated fire drills held at unexpected times. | Deficient, Provider has date of correction (July 24, 2024) |
| K-0741 | Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed. | Deficient, Provider has date of correction (July 24, 2024) |
| K-0920 | Ensure proper usage of power strips and extension cords. | Deficient, Provider has date of correction (July 24, 2024) |
March 24, 2023 — 10 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| E-0037 | Establish staff and initial training requirements. | Deficient, Provider has date of correction (May 1, 2023) |
| E-0039 | Conduct testing and exercise requirements. | Deficient, Provider has date of correction (May 1, 2023) |
| E-0041 | Implement emergency and standby power systems. | Deficient, Provider has date of correction (May 1, 2023) |
| K-0271 | Have exits that are accessible at all times. | Deficient, Provider has date of correction (May 1, 2023) |
| K-0353 | Inspect, test, and maintain automatic sprinkler systems. | Deficient, Provider has date of correction (May 1, 2023) |
| K-0374 | Install smoke barrier doors that can resist smoke for at least 20 minutes. | Deficient, Provider has date of correction (May 1, 2023) |
| K-0511 | Have properly installed electrical wiring and gas equipment. | Deficient, Provider has date of correction (May 1, 2023) |
| K-0712 | Have simulated fire drills held at unexpected times. | Deficient, Provider has date of correction (May 1, 2023) |
| K-0918 | Have generator or other power source capable of supplying service within 10 seconds. | Deficient, Provider has date of correction (May 1, 2023) |
| K-0920 | Ensure proper usage of power strips and extension cords. | Deficient, Provider has date of correction (May 1, 2023) |