Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record
WATERS OF WABASH SKILLED NURSING FACILITY EAST THE
WABASH, IN · 84 certified beds · Last Life Safety survey May 22, 2025
CMS Certification Number 155006 · first certified March 1974
Ownership
Operated by INFINITY HEALTHCARE CONSULTING · For profit - Limited Liability company
No change of ownership on CMS record since January 1, 2016, when the records begin.
Position within IN
42 citations — more than 96% of the 507 certified nursing homes in IN. Compared within IN rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated
The latest survey found 16 citations; the earlier surveys in the window averaged 13. With 3 surveys on file this is a direction of travel, not a conclusion.
When is the next survey likely?
Well past the typical window (May 2026 to July 2026), and past the point by which nine in ten IN facilities have been surveyed. This facility’s last Life Safety survey was May 2025. Facilities in IN are typically surveyed 11–14 months after the last one (median 13), measured over 883 consecutive surveys in the last two years of CMS records.
A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured
Get an email about WATERS OF WABASH SKILLED NURSING FACILITY EAST THE
One email when it happens. No account; stop it any time with one click.
4 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.
Emergency preparedness
10 of the 42 citations on file are Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index
Physical environment (health survey)
7 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 42 Life Safety citations above. The Physical Environment Index
- F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
- F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
- F-0880 Provide and implement an infection prevention and control program.
How that compares
Compared with the median facility in IN, and nationally. Surveyors differ markedly between states, so the IN figure is the meaningful one.
| Measure | Citations |
|---|---|
| This facility | 42 |
| Median facility in IN | 15 |
| Median facility nationally | 11 |
Survey history
| Survey date | Citations |
|---|---|
| June 30, 2023 | 7 |
| August 5, 2024 | 19 |
| May 22, 2025 | 16 |
Most-cited tags
| Tag | What the surveyor checks | Times cited | Last cited |
|---|---|---|---|
| K-0916 | Have a battery powered remote alarm panel in a location accessible by operating personnel. | 2 | 2025-05-22 |
| E-0039 | Conduct testing and exercise requirements. | 2 | 2024-08-05 |
| K-0363 | Install corridor and hallway doors that block smoke. | 2 | 2025-05-22 |
| K-0354 | Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours. | 2 | 2025-05-22 |
| K-0324 | Provide properly protected cooking facilities. | 2 | 2025-05-22 |
| K-0372 | Ensure smoke barriers are constructed to a 1 hour fire resistance rating. | 2 | 2024-08-05 |
| K-0346 | Follow proper procedures when the fire alarm was out of service for more than 4 hours. | 2 | 2025-05-22 |
| K-0918 | Have generator or other power source capable of supplying service within 10 seconds. | 2 | 2025-05-22 |
What the citations cover
- Smoke Deficiencies 13
- Emergency Preparedness Deficiencies 10
- Gas, Vacuum, and Electrical Systems Deficiencies 7
- Miscellaneous Deficiencies 4
- Other 8
| Category | Citations |
|---|---|
| Smoke Deficiencies | 13 |
| Emergency Preparedness Deficiencies | 10 |
| Gas, Vacuum, and Electrical Systems Deficiencies | 7 |
| Miscellaneous Deficiencies | 4 |
| Egress Deficiencies | 4 |
| Construction Deficiencies | 2 |
| Services Deficiencies | 2 |
Every citation on file
As published by CMS, newest survey first. Descriptions are CMS’s own wording.
May 22, 2025 — 16 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| E-0018 | Establish procedures for tracking staff and patients during an emergency. | Deficient, Provider has date of correction (July 28, 2025) |
| E-0041 | Implement emergency and standby power systems. | Deficient, Provider has date of correction (July 28, 2025) |
| K-0211 | Keep aisles, corridors, and exits free of obstruction in case of emergency. | Deficient, Provider has date of correction (July 28, 2025) |
| K-0271 | Have exits that are accessible at all times. | Deficient, Provider has date of correction (July 28, 2025) |
| K-0321 | Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. | Deficient, Provider has date of correction (July 28, 2025) |
| K-0324 | Provide properly protected cooking facilities. | Deficient, Provider has date of correction (July 28, 2025) |
| K-0345 | Have approved installation, maintenance and testing program for fire alarm systems. | Deficient, Provider has date of correction (July 28, 2025) |
| K-0346 | Follow proper procedures when the fire alarm was out of service for more than 4 hours. | Deficient, Provider has date of correction (July 28, 2025) |
| K-0354 | Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours. | Deficient, Provider has date of correction (July 28, 2025) |
| K-0363 | Install corridor and hallway doors that block smoke. | Deficient, Provider has date of correction (July 28, 2025) |
| K-0511 | Have properly installed electrical wiring and gas equipment. | Deficient, Provider has date of correction (July 28, 2025) |
| K-0712 | Have simulated fire drills held at unexpected times. | Deficient, Provider has date of correction (July 28, 2025) |
| K-0761 | To conduct inspection, testing and maintenance of fire doors by qualified individuals. | Deficient, Provider has date of correction (July 28, 2025) |
| K-0916 | Have a battery powered remote alarm panel in a location accessible by operating personnel. | Deficient, Provider has date of correction (July 28, 2025) |
| K-0918 | Have generator or other power source capable of supplying service within 10 seconds. | Deficient, Provider has date of correction (July 28, 2025) |
| K-0921 | Ensure that testing and maintenance of electrical equipment is performed. | Deficient, Provider has date of correction (July 28, 2025) |
August 5, 2024 — 19 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| E-0004 | Develop and maintain an Emergency Preparedness Program (EP). | Deficient, Provider has date of correction (October 8, 2024) |
| E-0013 | Develop Emergency Preparedness policies and procedures. | Deficient, Provider has date of correction (October 8, 2024) |
| E-0025 | Create arrangements with other facilities to receive patients. | Deficient, Provider has date of correction (October 8, 2024) |
| E-0029 | Develop a communication plan. | Deficient, Provider has date of correction (October 8, 2024) |
| E-0030 | List the names and contact information of those in the facility. | Deficient, Provider has date of correction (October 8, 2024) |
| E-0037 | Establish staff and initial training requirements. | Deficient, Provider has date of correction (October 8, 2024) |
| E-0039 | Conduct testing and exercise requirements. | Deficient, Provider has date of correction (October 8, 2024) |
| K-0161 | Use approved construction type or materials. | Deficient, Provider has date of correction (October 8, 2024) |
| K-0324 | Provide properly protected cooking facilities. | Deficient, Provider has date of correction (October 8, 2024) |
| K-0346 | Follow proper procedures when the fire alarm was out of service for more than 4 hours. | Deficient, Provider has date of correction (October 8, 2024) |
| K-0353 | Inspect, test, and maintain automatic sprinkler systems. | Deficient, Provider has date of correction (October 8, 2024) |
| K-0354 | Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours. | Deficient, Provider has date of correction (October 8, 2024) |
| K-0363 | Install corridor and hallway doors that block smoke. | Deficient, Provider has date of correction (October 8, 2024) |
| K-0372 | Ensure smoke barriers are constructed to a 1 hour fire resistance rating. | Deficient, Provider has date of correction (October 23, 2024) |
| K-0711 | Provide a written emergency evacuation plan. | Deficient, Provider has date of correction (October 8, 2024) |
| K-0754 | Provide properly sized and located linen or trash receptacles. | Deficient, Provider has date of correction (October 8, 2024) |
| K-0914 | Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing. | Deficient, Provider has date of correction (October 8, 2024) |
| K-0916 | Have a battery powered remote alarm panel in a location accessible by operating personnel. | Deficient, Provider has date of correction (October 8, 2024) |
| K-0927 | Have proper fire barriers, ventilation and signs for the transfilling of oxygen. | Deficient, Provider has date of correction (October 8, 2024) |
June 30, 2023 — 7 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| E-0039 | Conduct testing and exercise requirements. | Deficient, Provider has date of correction (September 19, 2023) |
| K-0100 | Meet other general requirements. | Deficient, Provider has date of correction (September 19, 2023) |
| K-0291 | Install emergency lighting that can last at least 1 1/2 hours. | Deficient, Provider has date of correction (September 19, 2023) |
| K-0300 | Meet other general requirements that are deficient. | Deficient, Provider has date of correction (September 19, 2023) |
| K-0372 | Ensure smoke barriers are constructed to a 1 hour fire resistance rating. | Deficient, Provider has date of correction (September 19, 2023) |
| K-0500 | Meet other general requirements that are deficient. | Deficient, Provider has date of correction (September 19, 2023) |
| K-0918 | Have generator or other power source capable of supplying service within 10 seconds. | Deficient, Provider has date of correction (September 19, 2023) |