Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

COMMUNITY HOSPITAL ONAGA LTCU

ST MARYS, KS · 26 certified beds · Last Life Safety survey October 31, 2024

CMS Certification Number 17E242 · first certified August 1974

Ownership

Independently operated (no chain recorded by CMS) · Non profit - Corporation

No change of ownership on CMS record since January 1, 2016, when the records begin.

20
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
3
Tags cited more than once
Across separate surveys
13
Inspection & testing records
Of the citations on file

Position within KS

20 citations — more than 23% of the 296 certified nursing homes in KS. Compared within KS rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 2 citations; the earlier surveys in the window averaged 9. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

Well past the typical window (June 2026 to September 2026), and past the point by which nine in ten KS facilities have been surveyed. This facility’s last Life Safety survey was October 2024. Facilities in KS are typically surveyed 20–22 months after the last one (median 21), measured over 298 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about COMMUNITY HOSPITAL ONAGA LTCU

One email when it happens. No account; stop it any time with one click.

Which alerts

3 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

2 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 20 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.

How that compares

Citations on file over three years

Compared with the median facility in KS, and nationally. Surveyors differ markedly between states, so the KS figure is the meaningful one.

This facility20KS median27National median11
Citations on file over three years, compared
MeasureCitations
This facility20
Median facility in KS27
Median facility nationally11

Survey history

Citations at each Life Safety survey
132021-1252023-0622024-10
Citations at each Life Safety survey
Survey dateCitations
December 21, 202113
June 19, 20235
October 31, 20242

Most-cited tags

Most-cited tags at this facility
K-03533K-03453K-03552K-09181K-07121K-09081K-03721K-01611
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0353Inspect, test, and maintain automatic sprinkler systems.32024-10-31
K-0345Have approved installation, maintenance and testing program for fire alarm systems.32024-10-31
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.22023-06-19
K-0918Have generator or other power source capable of supplying service within 10 seconds.12021-12-21
K-0712Have simulated fire drills held at unexpected times.12023-06-19
K-0908Ensure gas and vacuum systems are inspected and tested as part of a maintenance program.12021-12-21
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.12021-12-21
K-0161Use approved construction type or materials.12023-06-19

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 12
  • Gas, Vacuum, and Electrical Systems Deficiencies 5
  • Egress Deficiencies 1
  • Miscellaneous Deficiencies 1
  • Other 1
Citations by CMS category
CategoryCitations
Smoke Deficiencies12
Gas, Vacuum, and Electrical Systems Deficiencies5
Egress Deficiencies1
Miscellaneous Deficiencies1
Construction Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

October 31, 2024 — 2 citations

Citations issued on October 31, 2024
TagWhat the surveyor checksStatus
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (December 23, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (December 23, 2024)

June 19, 2023 — 5 citations

Citations issued on June 19, 2023
TagWhat the surveyor checksStatus
K-0161Use approved construction type or materials.Deficient, Provider has date of correction (August 12, 2023)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (August 12, 2023)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (August 12, 2023)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (August 12, 2023)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (August 12, 2023)

December 21, 2021 — 13 citations

Citations issued on December 21, 2021
TagWhat the surveyor checksStatus
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (February 28, 2022)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (February 28, 2022)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (February 28, 2022)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Waiver has been granted (February 28, 2022)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (February 28, 2022)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (February 28, 2022)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (February 28, 2022)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (February 28, 2022)
K-0902Meet requirements for the installation and maintenance of medical gas and medical vacuum systems.Deficient, Provider has date of correction (February 28, 2022)
K-0908Ensure gas and vacuum systems are inspected and tested as part of a maintenance program.Deficient, Provider has date of correction (February 28, 2022)
K-0916Have a battery powered remote alarm panel in a location accessible by operating personnel.Deficient, Provider has date of correction (February 28, 2022)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (February 28, 2022)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (February 28, 2022)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.