Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Many Healthcare and Rehabilitation Center

Many, LA · 162 certified beds · Last Life Safety survey March 11, 2026

CMS Certification Number 195310 · first certified February 1995

Ownership

Operated by NEXION HEALTH · For profit - Corporation

No change of ownership on CMS record since January 1, 2016, when the records begin.

10
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
3
Tags cited more than once
Across separate surveys
5
Inspection & testing records
Of the citations on file

Position within LA

10 citations — more than 96% of the 265 certified nursing homes in LA. Compared within LA rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 4 citations; the earlier surveys in the window averaged 3. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens March 2027 — about 5 months from now. This facility’s last Life Safety survey was March 2026. Facilities in LA are typically surveyed 12–13 months after the last one (median 13), measured over 458 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about Many Healthcare and Rehabilitation Center

One email when it happens. No account; stop it any time with one click.

Which alerts

2 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

7 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 10 Life Safety citations above. The Physical Environment Index

  • F-0921 Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.

How that compares

Citations on file over three years

Compared with the median facility in LA, and nationally. Surveyors differ markedly between states, so the LA figure is the meaningful one.

This facility10LA median2National median11
Citations on file over three years, compared
MeasureCitations
This facility10
Median facility in LA2
Median facility nationally11

Survey history

Citations at each Life Safety survey
52023-1212025-0142026-03
Citations at each Life Safety survey
Survey dateCitations
December 13, 20235
January 14, 20251
March 11, 20264

Most-cited tags

Most-cited tags at this facility
K-09202K-05212K-03532K-02111K-01111K-02211K-03451
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0920Ensure proper usage of power strips and extension cords.22026-03-11
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.22026-03-11
K-0353Inspect, test, and maintain automatic sprinkler systems.22026-03-11
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.12023-12-13
K-0111Satisfy building requirements after a repair, renovation, modification, or change of user/occupancy.12026-03-11
K-0221Provide rooms that can be unlocked from inside without a key.12023-12-13
K-0345Have approved installation, maintenance and testing program for fire alarm systems.12023-12-13

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 3
  • Egress Deficiencies 2
  • Services Deficiencies 2
  • Gas, Vacuum, and Electrical Systems Deficiencies 2
  • Other 1
Citations by CMS category
CategoryCitations
Smoke Deficiencies3
Egress Deficiencies2
Services Deficiencies2
Gas, Vacuum, and Electrical Systems Deficiencies2
Construction Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

March 11, 2026 — 4 citations

Citations issued on March 11, 2026
TagWhat the surveyor checksStatus
K-0111Satisfy building requirements after a repair, renovation, modification, or change of user/occupancy.Deficient, Provider has date of correction (March 27, 2026)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (March 26, 2026)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.No revisit needed
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (March 26, 2026)

January 14, 2025 — 1 citation

Citations issued on January 14, 2025
TagWhat the surveyor checksStatus
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (February 25, 2025)

December 13, 2023 — 5 citations

Citations issued on December 13, 2023
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (January 12, 2024)
K-0221Provide rooms that can be unlocked from inside without a key.Deficient, Provider has date of correction (January 12, 2024)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (January 12, 2024)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (December 14, 2023)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (January 12, 2024)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.