Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Harmony Village of Beverly Hills

Beverly Hills, MI · 96 certified beds · Last Life Safety survey June 3, 2026

CMS Certification Number 235664 · first certified May 2013

Ownership

Operated by CERTUS HEALTHCARE · For profit - Corporation

  • New ownershipOwnership changed November 1, 2025 (change of ownership)from MISSION POINT OF BEVERLY HILLS LLC
8
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
2
Tags cited more than once
Across separate surveys
6
Inspection & testing records
Of the citations on file

Position within MI

8 citations — more than 23% of the 422 certified nursing homes in MI. Compared within MI rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 1 citation; the earlier surveys in the window averaged 3.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens May 2027 — about 8 months from now. This facility’s last Life Safety survey was June 2026. Facilities in MI are typically surveyed 12–14 months after the last one (median 13), measured over 723 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about Harmony Village of Beverly Hills

One email when it happens. No account; stop it any time with one click.

Which alerts

1 inspection-and-testing tag has been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

17 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 8 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0923 Have enough outside ventilation via a window or mechanical ventilation, or both.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0908 Keep all essential equipment working safely.
  • F-0925 Make sure there is a pest control program to prevent/deal with mice, insects, or other pests.
  • F-0921 Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public.
  • F-0919 Make sure that a working call system is available in each resident's bathroom and bathing area.

How that compares

Citations on file over three years

Compared with the median facility in MI, and nationally. Surveyors differ markedly between states, so the MI figure is the meaningful one.

This facility8MI median14National median11
Citations on file over three years, compared
MeasureCitations
This facility8
Median facility in MI14
Median facility nationally11

Survey history

Citations at each Life Safety survey
22025-0652025-1212026-06
Citations at each Life Safety survey
Survey dateCitations
June 11, 20252
December 4, 20255
June 3, 20261

Most-cited tags

Most-cited tags at this facility
K-09182K-02112K-03531K-05111K-03451K-03631
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0918Have generator or other power source capable of supplying service within 10 seconds.22025-12-04
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.22025-12-04
K-0353Inspect, test, and maintain automatic sprinkler systems.12025-12-04
K-0511Have properly installed electrical wiring and gas equipment.12025-12-04
K-0345Have approved installation, maintenance and testing program for fire alarm systems.12026-06-03
K-0363Install corridor and hallway doors that block smoke.12025-12-04

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 3
  • Gas, Vacuum, and Electrical Systems Deficiencies 2
  • Egress Deficiencies 2
  • Services Deficiencies 1
Citations by CMS category
CategoryCitations
Smoke Deficiencies3
Gas, Vacuum, and Electrical Systems Deficiencies2
Egress Deficiencies2
Services Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

June 3, 2026 — 1 citation

Citations issued on June 3, 2026
TagWhat the surveyor checksStatus
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (June 26, 2026)

December 4, 2025 — 5 citations

Citations issued on December 4, 2025
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (January 1, 2026)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (January 1, 2026)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (January 1, 2026)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (January 1, 2026)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (January 1, 2026)

June 11, 2025 — 2 citations

Citations issued on June 11, 2025
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (July 3, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (July 3, 2025)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.