Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Optalis Health & Rehabilitation of Ionia

Ionia, MI · 107 certified beds · Last Life Safety survey March 25, 2026

CMS Certification Number 235032 · first certified January 1967

Ownership

Operated by OPTALIS HEALTH & REHABILITATION · For profit - Corporation

  • New ownershipOwnership changed July 1, 2025 (change of ownership)from IONIA SNF LLC
19
Citations on file
CMS's current file
3
Life Safety surveys
CMS's current file
1
Tags cited more than once
Across separate surveys
6
Inspection & testing records
Of the citations on file

Position within MI

19 citations — more than 71% of the 422 certified nursing homes in MI. Compared within MI rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in CMS's current file.

The latest survey found 17 citations; the earlier surveys on file averaged 1. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens March 2027 — about 4 months from now. This facility’s last Life Safety survey was March 2026. Facilities in MI are typically surveyed 12–14 months after the last one (median 13), measured over 731 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to about three years in Virginia. How the window is measured

Get an email about Optalis Health & Rehabilitation of Ionia

One email when it happens. No account; stop it any time with one click.

Which alerts

1 inspection-and-testing tag has been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities cited for sprinkler inspection and testing in CMS’s current file are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Emergency preparedness

5 of the 19 citations on file are Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

6 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 19 Life Safety citations above. The Physical Environment Index

  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.

How that compares

Citations in CMS's current file

Compared with the median facility in MI, and nationally. Surveyors differ markedly between states, so the MI figure is the meaningful one.

This facility19MI median13National median11
Citations in CMS's current file, compared
MeasureCitations
This facility19
Median facility in MI13
Median facility nationally11

Survey history

Citations at each Life Safety survey
02024-0322025-03172026-03
Citations at each Life Safety survey
Survey dateCitations
March 6, 20240
March 6, 20252
March 25, 202617

Most-cited tags

Most-cited tags at this facility
K-09182E-00151K-03451K-03551E-00391K-03241K-03531E-00291
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0918Have generator or other power source capable of supplying service within 10 seconds.22026-03-25
E-0015Address subsistence needs for staff and patients.12026-03-25
K-0345Have approved installation, maintenance and testing program for fire alarm systems.12026-03-25
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.12025-03-06
E-0039Conduct testing and exercise requirements.12026-03-25
K-0324Provide properly protected cooking facilities.12026-03-25
K-0353Inspect, test, and maintain automatic sprinkler systems.12026-03-25
E-0029Develop a communication plan.12026-03-25

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 6
  • Emergency Preparedness Deficiencies 5
  • Egress Deficiencies 3
  • Gas, Vacuum, and Electrical Systems Deficiencies 3
  • Other 2
Citations by CMS category
CategoryCitations
Smoke Deficiencies6
Emergency Preparedness Deficiencies5
Egress Deficiencies3
Gas, Vacuum, and Electrical Systems Deficiencies3
Miscellaneous Deficiencies2

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

March 25, 2026 — 17 citations

Citations issued on March 25, 2026
TagWhat the surveyor checksStatus
E-0009Include a process for Emergency Preparedness collaboration.Deficient, Provider has date of correction (April 17, 2026)
E-0015Address subsistence needs for staff and patients.Deficient, Provider has date of correction (April 17, 2026)
E-0029Develop a communication plan.Deficient, Provider has date of correction (April 17, 2026)
E-0030List the names and contact information of those in the facility.Deficient, Provider has date of correction (April 17, 2026)
E-0039Conduct testing and exercise requirements.Deficient, Provider has date of correction (April 17, 2026)
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (April 17, 2026)
K-0223Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.Deficient, Provider has date of correction (April 17, 2026)
K-0271Have exits that are accessible at all times.Deficient, Provider has date of correction (April 17, 2026)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (April 17, 2026)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (April 17, 2026)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (April 17, 2026)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (April 17, 2026)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (April 17, 2026)
K-0711Provide a written emergency evacuation plan.Deficient, Provider has date of correction (April 17, 2026)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (April 17, 2026)
K-0912Have power receptacles that are properly grounded.Deficient, Provider has date of correction (April 17, 2026)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (April 17, 2026)

March 6, 2025 — 2 citations

Citations issued on March 6, 2025
TagWhat the surveyor checksStatus
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (March 18, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (March 18, 2025)

Reflects the CMS posting of October 1, 2026. Surveys conducted in the last few months may not appear yet.