Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Regency at Whitmore Lake

Whitmore Lake, MI · 131 certified beds · Last Life Safety survey May 15, 2026

CMS Certification Number 235545 · first certified November 1994

Ownership

Operated by CIENA HEALTHCARE/LAUREL HEALTH CARE · For profit - Corporation

No change of ownership on CMS record since January 1, 2016, when the records begin.

25
Citations on file
CMS's current file
3
Life Safety surveys
CMS's current file
6
Tags cited more than once
Across separate surveys
14
Inspection & testing records
Of the citations on file

Position within MI

25 citations — more than 84% of the 422 certified nursing homes in MI. Compared within MI rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in CMS's current file.

The latest survey found 1 citation; the earlier surveys on file averaged 12. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens May 2027 — about 6 months from now. This facility’s last Life Safety survey was May 2026. Facilities in MI are typically surveyed 12–14 months after the last one (median 13), measured over 731 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to about three years in Virginia. How the window is measured

Get an email about Regency at Whitmore Lake

One email when it happens. No account; stop it any time with one click.

Which alerts

4 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities cited for sprinkler inspection and testing in CMS’s current file are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

11 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 25 Life Safety citations above. The Physical Environment Index

  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0921 Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public.
  • F-0919 Make sure that a working call system is available in each resident's bathroom and bathing area.

How that compares

Citations in CMS's current file

Compared with the median facility in MI, and nationally. Surveyors differ markedly between states, so the MI figure is the meaningful one.

This facility25MI median13National median11
Citations in CMS's current file, compared
MeasureCitations
This facility25
Median facility in MI13
Median facility nationally11

Survey history

Citations at each Life Safety survey
102024-03142025-0312026-05
Citations at each Life Safety survey
Survey dateCitations
March 5, 202410
March 31, 202514
May 15, 20261

Most-cited tags

Most-cited tags at this facility
K-03242K-05112K-09182K-03532K-03212K-02112K-02221K-09121
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0324Provide properly protected cooking facilities.22025-03-31
K-0511Have properly installed electrical wiring and gas equipment.22025-03-31
K-0918Have generator or other power source capable of supplying service within 10 seconds.22025-03-31
K-0353Inspect, test, and maintain automatic sprinkler systems.22025-03-31
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.22025-03-31
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.22026-05-15
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.12025-03-31
K-0912Have power receptacles that are properly grounded.12025-03-31

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 10
  • Gas, Vacuum, and Electrical Systems Deficiencies 5
  • Miscellaneous Deficiencies 3
  • Egress Deficiencies 3
  • Other 4
Citations by CMS category
CategoryCitations
Smoke Deficiencies10
Gas, Vacuum, and Electrical Systems Deficiencies5
Miscellaneous Deficiencies3
Egress Deficiencies3
Services Deficiencies3
Construction Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

May 15, 2026 — 1 citation

Citations issued on May 15, 2026
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (June 21, 2026)

March 31, 2025 — 14 citations

Citations issued on March 31, 2025
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Waiver has been granted (April 25, 2025)
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Waiver has been granted (June 24, 2025)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (April 25, 2025)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (April 25, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (April 25, 2025)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (April 25, 2025)
K-0363Install corridor and hallway doors that block smoke.Waiver has been granted (June 24, 2025)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (April 25, 2025)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (April 25, 2025)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (April 25, 2025)
K-0781Have restrictions on the use of portable space heaters.Deficient, Provider has date of correction (April 25, 2025)
K-0912Have power receptacles that are properly grounded.Deficient, Provider has date of correction (April 25, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (April 25, 2025)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (April 25, 2025)

March 5, 2024 — 10 citations

Citations issued on March 5, 2024
TagWhat the surveyor checksStatus
K-0100Meet other general requirements.Deficient, Provider has date of correction (April 14, 2024)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (April 14, 2024)
K-0324Provide properly protected cooking facilities.Waiver has been granted (April 17, 2024)
K-0341Install a fire alarm system that can be heard throughout the facility.Deficient, Provider has date of correction (April 14, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (April 14, 2024)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (April 14, 2024)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (April 14, 2024)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (April 14, 2024)
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.Deficient, Provider has date of correction (April 14, 2024)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (April 14, 2024)

Reflects the CMS posting of October 1, 2026. Surveys conducted in the last few months may not appear yet.