Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

FAIR MEADOW NURSING HOME

FERTILE, MN · 42 certified beds · Last Life Safety survey September 10, 2025

CMS Certification Number 245545 · first certified February 1991

Ownership

Independently operated (no chain recorded by CMS) · Non profit - Other

No change of ownership on CMS record since January 1, 2016, when the records begin.

17
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
2
Tags cited more than once
Across separate surveys
11
Inspection & testing records
Of the citations on file

Position within MN

17 citations — more than 72% of the 338 certified nursing homes in MN. Compared within MN rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 2 citations; the earlier surveys in the window averaged 7.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window is open now: August 2026 to November 2026. This facility’s last Life Safety survey was September 2025. Facilities in MN are typically surveyed 11–14 months after the last one (median 13), measured over 613 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about FAIR MEADOW NURSING HOME

One email when it happens. No account; stop it any time with one click.

Which alerts

2 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

4 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 17 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.

How that compares

Citations on file over three years

Compared with the median facility in MN, and nationally. Surveyors differ markedly between states, so the MN figure is the meaningful one.

This facility17MN median12National median11
Citations on file over three years, compared
MeasureCitations
This facility17
Median facility in MN12
Median facility nationally11

Survey history

Citations at each Life Safety survey
72023-0682024-0822025-09
Citations at each Life Safety survey
Survey dateCitations
June 14, 20237
August 27, 20248
September 10, 20252

Most-cited tags

Most-cited tags at this facility
K-03533K-03722K-09121K-09181K-02221K-07611K-03541K-09201
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0353Inspect, test, and maintain automatic sprinkler systems.32025-09-10
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.22024-08-27
K-0912Have power receptacles that are properly grounded.12024-08-27
K-0918Have generator or other power source capable of supplying service within 10 seconds.12023-06-14
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.12023-06-14
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.12025-09-10
K-0354Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours.12024-08-27
K-0920Ensure proper usage of power strips and extension cords.12024-08-27

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 9
  • Gas, Vacuum, and Electrical Systems Deficiencies 3
  • Services Deficiencies 2
  • Miscellaneous Deficiencies 2
  • Other 1
Citations by CMS category
CategoryCitations
Smoke Deficiencies9
Gas, Vacuum, and Electrical Systems Deficiencies3
Services Deficiencies2
Miscellaneous Deficiencies2
Egress Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

September 10, 2025 — 2 citations

Citations issued on September 10, 2025
TagWhat the surveyor checksStatus
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (November 14, 2025)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (November 14, 2025)

August 27, 2024 — 8 citations

Citations issued on August 27, 2024
TagWhat the surveyor checksStatus
K-0346Follow proper procedures when the fire alarm was out of service for more than 4 hours.Deficient, Provider has date of correction (October 3, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (October 3, 2024)
K-0354Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours.Deficient, Provider has date of correction (October 3, 2024)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (October 3, 2024)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (October 3, 2024)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (October 3, 2024)
K-0912Have power receptacles that are properly grounded.Deficient, Provider has date of correction (October 3, 2024)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (October 3, 2024)

June 14, 2023 — 7 citations

Citations issued on June 14, 2023
TagWhat the surveyor checksStatus
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (August 16, 2023)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (August 16, 2023)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (August 16, 2023)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (August 16, 2023)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (August 16, 2023)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (August 16, 2023)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (August 16, 2023)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.