Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

CENTRAL HEALTH CARE CENTER

LE CENTER, MN · 40 certified beds · Last Life Safety survey February 10, 2026

CMS Certification Number 245401 · first certified December 1986

Ownership

Independently operated (no chain recorded by CMS) · For profit - Corporation

No change of ownership on CMS record since January 1, 2016, when the records begin.

24
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
5
Tags cited more than once
Across separate surveys
12
Inspection & testing records
Of the citations on file

Position within MN

24 citations — more than 88% of the 338 certified nursing homes in MN. Compared within MN rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 3 citations; the earlier surveys in the window averaged 10.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens January 2027 — about 3 months from now. This facility’s last Life Safety survey was February 2026. Facilities in MN are typically surveyed 11–14 months after the last one (median 13), measured over 613 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about CENTRAL HEALTH CARE CENTER

One email when it happens. No account; stop it any time with one click.

Which alerts

3 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Emergency preparedness

5 of the 24 citations on file are Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

4 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 24 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.

How that compares

Citations on file over three years

Compared with the median facility in MN, and nationally. Surveyors differ markedly between states, so the MN figure is the meaningful one.

This facility24MN median12National median11
Citations on file over three years, compared
MeasureCitations
This facility24
Median facility in MN12
Median facility nationally11

Survey history

Citations at each Life Safety survey
72024-01142025-0332026-02
Citations at each Life Safety survey
Survey dateCitations
January 4, 20247
March 10, 202514
February 10, 20263

Most-cited tags

Most-cited tags at this facility
K-03212E-00392K-07122K-09182K-03452K-09161E-00061K-09231
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.22026-02-10
E-0039Conduct testing and exercise requirements.22025-03-10
K-0712Have simulated fire drills held at unexpected times.22026-02-10
K-0918Have generator or other power source capable of supplying service within 10 seconds.22025-03-10
K-0345Have approved installation, maintenance and testing program for fire alarm systems.22025-03-10
K-0916Have a battery powered remote alarm panel in a location accessible by operating personnel.12025-03-10
E-0006Conduct risk assessment and an All-Hazards approach.12024-01-04
K-0923Have proper medical gas storage and administration areas.12025-03-10

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 7
  • Gas, Vacuum, and Electrical Systems Deficiencies 6
  • Emergency Preparedness Deficiencies 5
  • Miscellaneous Deficiencies 5
  • Other 1
Citations by CMS category
CategoryCitations
Smoke Deficiencies7
Gas, Vacuum, and Electrical Systems Deficiencies6
Emergency Preparedness Deficiencies5
Miscellaneous Deficiencies5
Egress Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

February 10, 2026 — 3 citations

Citations issued on February 10, 2026
TagWhat the surveyor checksStatus
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (February 27, 2026)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (March 2, 2026)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (February 11, 2026)

March 10, 2025 — 14 citations

Citations issued on March 10, 2025
TagWhat the surveyor checksStatus
E-0039Conduct testing and exercise requirements.Deficient, Provider has date of correction (April 10, 2025)
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (March 31, 2025)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (March 31, 2025)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (March 31, 2025)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (March 31, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (March 31, 2025)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (March 31, 2025)
K-0711Provide a written emergency evacuation plan.Deficient, Provider has date of correction (March 31, 2025)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (March 31, 2025)
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.Deficient, Provider has date of correction (March 31, 2025)
K-0916Have a battery powered remote alarm panel in a location accessible by operating personnel.Deficient, Provider has date of correction (March 31, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (March 31, 2025)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (March 31, 2025)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (March 31, 2025)

January 4, 2024 — 7 citations

Citations issued on January 4, 2024
TagWhat the surveyor checksStatus
E-0004Develop and maintain an Emergency Preparedness Program (EP).Deficient, Provider has date of correction (March 2, 2024)
E-0006Conduct risk assessment and an All-Hazards approach.Deficient, Provider has date of correction (March 2, 2024)
E-0039Conduct testing and exercise requirements.Deficient, Provider has date of correction (March 2, 2024)
E-0041Implement emergency and standby power systems.Deficient, Provider has date of correction (January 5, 2024)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (January 26, 2024)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (January 26, 2024)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (January 26, 2024)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.