Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

ST GERTRUDES HEALTH & REHABILITATION CENTER

SHAKOPEE, MN · 105 certified beds · Last Life Safety survey January 15, 2026

CMS Certification Number 245610 · first certified November 1996

Ownership

Operated by BENEDICTINE HEALTH SYSTEM · For profit - Limited Liability company

No change of ownership on CMS record since January 1, 2016, when the records begin.

20
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
5
Tags cited more than once
Across separate surveys
14
Inspection & testing records
Of the citations on file

Position within MN

20 citations — more than 82% of the 338 certified nursing homes in MN. Compared within MN rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 5 citations; the earlier surveys in the window averaged 7.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens December 2026 — about 3 months from now. This facility’s last Life Safety survey was January 2026. Facilities in MN are typically surveyed 11–14 months after the last one (median 13), measured over 613 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about ST GERTRUDES HEALTH & REHABILITATION CENTER

One email when it happens. No account; stop it any time with one click.

Which alerts

4 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

3 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 20 Life Safety citations above. The Physical Environment Index

  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.

How that compares

Citations on file over three years

Compared with the median facility in MN, and nationally. Surveyors differ markedly between states, so the MN figure is the meaningful one.

This facility20MN median12National median11
Citations on file over three years, compared
MeasureCitations
This facility20
Median facility in MN12
Median facility nationally11

Survey history

Citations at each Life Safety survey
92023-1262024-1052026-01
Citations at each Life Safety survey
Survey dateCitations
December 14, 20239
October 31, 20246
January 15, 20265

Most-cited tags

Most-cited tags at this facility
K-09183K-03742K-03532K-09232K-03452K-07611K-03241K-02931
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0918Have generator or other power source capable of supplying service within 10 seconds.32026-01-15
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.22026-01-15
K-0353Inspect, test, and maintain automatic sprinkler systems.22026-01-15
K-0923Have proper medical gas storage and administration areas.22024-10-31
K-0345Have approved installation, maintenance and testing program for fire alarm systems.22024-10-31
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.12026-01-15
K-0324Provide properly protected cooking facilities.12023-12-14
K-0293Have properly located and lighted "Exit" signs.12023-12-14

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 9
  • Gas, Vacuum, and Electrical Systems Deficiencies 7
  • Miscellaneous Deficiencies 2
  • Egress Deficiencies 2
Citations by CMS category
CategoryCitations
Smoke Deficiencies9
Gas, Vacuum, and Electrical Systems Deficiencies7
Miscellaneous Deficiencies2
Egress Deficiencies2

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

January 15, 2026 — 5 citations

Citations issued on January 15, 2026
TagWhat the surveyor checksStatus
K-0344Have an alternate power supply for its alarm system.Deficient, Provider has date of correction (February 18, 2026)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (February 18, 2026)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has plan of correction
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has plan of correction
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (March 3, 2026)

October 31, 2024 — 6 citations

Citations issued on October 31, 2024
TagWhat the surveyor checksStatus
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (December 4, 2024)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (December 4, 2024)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (December 6, 2024)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (December 4, 2024)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (December 4, 2024)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (December 4, 2024)

December 14, 2023 — 9 citations

Citations issued on December 14, 2023
TagWhat the surveyor checksStatus
K-0293Have properly located and lighted "Exit" signs.Deficient, Provider has date of correction (January 10, 2024)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (January 12, 2024)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (January 10, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (January 17, 2024)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (January 10, 2024)
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.Deficient, Provider has date of correction (January 10, 2024)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (January 10, 2024)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (January 10, 2024)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (January 10, 2024)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.