Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

ABBEY SENIOR HEALTH

O FALLON, MO · 55 certified beds · Last Life Safety survey June 11, 2026

CMS Certification Number 265839 · first certified March 2011

Ownership

Independently operated (no chain recorded by CMS) · For profit - Limited Liability company

No change of ownership on CMS record since January 1, 2016, when the records begin.

26
Citations on file
CMS's current file
3
Life Safety surveys
CMS's current file
6
Tags cited more than once
Across separate surveys
10
Inspection & testing records
Of the citations on file

Position within MO

26 citations — more than 70% of the 486 certified nursing homes in MO. Compared within MO rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in CMS's current file.

The latest survey found 6 citations; the earlier surveys on file averaged 10. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens August 2027 — about 9 months from now. This facility’s last Life Safety survey was June 2026. Facilities in MO are typically surveyed 14–21 months after the last one (median 17), measured over 523 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to about three years in Virginia. How the window is measured

Get an email about ABBEY SENIOR HEALTH

One email when it happens. No account; stop it any time with one click.

Which alerts

4 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities cited for sprinkler inspection and testing in CMS’s current file are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Emergency preparedness

3 of the 26 citations on file are Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

5 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 26 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0909 Regularly inspect all bed frames, mattresses, and bed rails (if any) for safety; and all bed rails and mattresses must attach safely to the bed frame.

How that compares

Citations in CMS's current file

Compared with the median facility in MO, and nationally. Surveyors differ markedly between states, so the MO figure is the meaningful one.

This facility26MO median18National median11
Citations in CMS's current file, compared
MeasureCitations
This facility26
Median facility in MO18
Median facility nationally11

Survey history

Citations at each Life Safety survey
152023-0652024-1062026-06
Citations at each Life Safety survey
Survey dateCitations
June 9, 202315
October 25, 20245
June 11, 20266

Most-cited tags

Most-cited tags at this facility
K-01612K-09182K-07122K-03532K-03242K-03112K-09321E-00251
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0161Use approved construction type or materials.22024-10-25
K-0918Have generator or other power source capable of supplying service within 10 seconds.22026-06-11
K-0712Have simulated fire drills held at unexpected times.22024-10-25
K-0353Inspect, test, and maintain automatic sprinkler systems.22024-10-25
K-0324Provide properly protected cooking facilities.22026-06-11
K-0311Have an enclosure around a vertical opening shaft.22024-10-25
K-0932Meet other general requirements.12023-06-09
E-0025Create arrangements with other facilities to receive patients.12023-06-09

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 11
  • Gas, Vacuum, and Electrical Systems Deficiencies 4
  • Emergency Preparedness Deficiencies 3
  • Miscellaneous Deficiencies 3
  • Other 5
Citations by CMS category
CategoryCitations
Smoke Deficiencies11
Gas, Vacuum, and Electrical Systems Deficiencies4
Emergency Preparedness Deficiencies3
Miscellaneous Deficiencies3
Egress Deficiencies2
Construction Deficiencies2
Services Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

June 11, 2026 — 6 citations

Citations issued on June 11, 2026
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (July 31, 2026)
K-0293Have properly located and lighted "Exit" signs.Deficient, Provider has date of correction (July 31, 2026)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (July 31, 2026)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (July 31, 2026)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (July 31, 2026)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (July 31, 2026)

October 25, 2024 — 5 citations

Citations issued on October 25, 2024
TagWhat the surveyor checksStatus
K-0161Use approved construction type or materials.Waiver has been granted
K-0311Have an enclosure around a vertical opening shaft.Deficient, Provider has date of correction (December 13, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (December 13, 2024)
K-0531Have elevators that firefighters can control in the event of a fire.Deficient, Provider has date of correction (December 13, 2024)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (December 13, 2024)

June 9, 2023 — 15 citations

Citations issued on June 9, 2023
TagWhat the surveyor checksStatus
E-0015Address subsistence needs for staff and patients.Deficient, Provider has date of correction (July 24, 2023)
E-0020Establish policies and procedures including evacuation.Deficient, Provider has date of correction (July 24, 2023)
E-0025Create arrangements with other facilities to receive patients.Deficient, Provider has date of correction (July 24, 2023)
K-0161Use approved construction type or materials.Waiver has been granted (December 15, 2023)
K-0311Have an enclosure around a vertical opening shaft.Deficient, Provider has date of correction (July 24, 2023)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (July 24, 2023)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (July 24, 2023)
K-0341Install a fire alarm system that can be heard throughout the facility.Deficient, Provider has date of correction (July 24, 2023)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (July 24, 2023)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (July 24, 2023)
K-0711Provide a written emergency evacuation plan.Deficient, Provider has date of correction (July 24, 2023)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (July 24, 2023)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (July 24, 2023)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (July 24, 2023)
K-0932Meet other general requirements.Deficient, Provider has date of correction (July 24, 2023)

Reflects the CMS posting of October 1, 2026. Surveys conducted in the last few months may not appear yet.