Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record
SHARKEY-ISSAQUENA NURSING HOME
ROLLING FORK, MS · 54 certified beds · Last Life Safety survey October 3, 2024
CMS Certification Number 255220 · first certified January 1996
Ownership
Independently operated (no chain recorded by CMS) · Government - County
No change of ownership on CMS record since January 1, 2016, when the records begin.
Position within MS
4 citations — more than 95% of the 202 certified nursing homes in MS. Compared within MS rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated
The latest survey found 1 citation; the earlier surveys in the window averaged 1.5. With 3 surveys on file this is a direction of travel, not a conclusion.
When is the next survey likely?
Well past the typical window (January 2026 to April 2026), and past the point by which nine in ten MS facilities have been surveyed. This facility’s last Life Safety survey was October 2024. Facilities in MS are typically surveyed 15–19 months after the last one (median 17), measured over 258 consecutive surveys in the last two years of CMS records.
A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured
Get an email about SHARKEY-ISSAQUENA NURSING HOME
One email when it happens. No account; stop it any time with one click.
1 inspection-and-testing tag has been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.
Physical environment (health survey)
2 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 4 Life Safety citations above. The Physical Environment Index
- F-0880 Provide and implement an infection prevention and control program.
How that compares
Compared with the median facility in MS, and nationally. Surveyors differ markedly between states, so the MS figure is the meaningful one.
| Measure | Citations |
|---|---|
| This facility | 4 |
| Median facility in MS | 1 |
| Median facility nationally | 11 |
Survey history
| Survey date | Citations |
|---|---|
| October 11, 2018 | 0 |
| December 17, 2019 | 3 |
| October 3, 2024 | 1 |
Most-cited tags
| Tag | What the surveyor checks | Times cited | Last cited |
|---|---|---|---|
| K-0918 | Have generator or other power source capable of supplying service within 10 seconds. | 2 | 2024-10-03 |
| K-0222 | Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements. | 1 | 2019-12-17 |
| K-0211 | Keep aisles, corridors, and exits free of obstruction in case of emergency. | 1 | 2019-12-17 |
What the citations cover
- Egress Deficiencies 2
- Gas, Vacuum, and Electrical Systems Deficiencies 2
| Category | Citations |
|---|---|
| Egress Deficiencies | 2 |
| Gas, Vacuum, and Electrical Systems Deficiencies | 2 |
Every citation on file
As published by CMS, newest survey first. Descriptions are CMS’s own wording.
October 3, 2024 — 1 citation
| Tag | What the surveyor checks | Status |
|---|---|---|
| K-0918 | Have generator or other power source capable of supplying service within 10 seconds. | Deficient, Provider has date of correction (October 30, 2024) |
December 17, 2019 — 3 citations
| Tag | What the surveyor checks | Status |
|---|---|---|
| K-0211 | Keep aisles, corridors, and exits free of obstruction in case of emergency. | Deficient, Provider has date of correction (February 4, 2020) |
| K-0222 | Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements. | Deficient, Provider has date of correction (February 4, 2020) |
| K-0918 | Have generator or other power source capable of supplying service within 10 seconds. | Deficient, Provider has date of correction (February 4, 2020) |
Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.