Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Accura Healthcare of Neligh

Neligh, NE · 70 certified beds · Last Life Safety survey May 7, 2026

CMS Certification Number 285124 · first certified October 1992

Ownership

Independently operated (no chain recorded by CMS) · For profit - Corporation

  • Ownership changed August 1, 2019 (change of ownership)to ARBOR CARE CENTERS - NELIGH LLC from NELIGH OPERATIONS LLC
17
Citations on file
Rolling three-year window
4
Life Safety surveys
In the same window
3
Tags cited more than once
Across separate surveys
8
Inspection & testing records
Of the citations on file

Position within NE

17 citations — more than 56% of the 180 certified nursing homes in NE. Compared within NE rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 4 citations; the earlier surveys in the window averaged 7. With 4 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens May 2027 — about 7 months from now. This facility’s last Life Safety survey was May 2026. Facilities in NE are typically surveyed 12–14 months after the last one (median 13), measured over 271 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about Accura Healthcare of Neligh

One email when it happens. No account; stop it any time with one click.

Which alerts

3 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Emergency preparedness

4 of the 17 citations on file are Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

6 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 17 Life Safety citations above. The Physical Environment Index

  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.

How that compares

Citations on file over three years

Compared with the median facility in NE, and nationally. Surveyors differ markedly between states, so the NE figure is the meaningful one.

This facility17NE median15National median11
Citations on file over three years, compared
MeasureCitations
This facility17
Median facility in NE15
Median facility nationally11

Survey history

Citations at each Life Safety survey
82024-0382024-0352025-0342026-05
Citations at each Life Safety survey
Survey dateCitations
March 19, 20248
March 19, 20248
March 25, 20255
May 7, 20264

Most-cited tags

Most-cited tags at this facility
K-07122K-03242K-07612E-00371E-00201K-09221E-00411K-09111
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0712Have simulated fire drills held at unexpected times.22025-03-25
K-0324Provide properly protected cooking facilities.22026-05-07
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.22026-05-07
E-0037Establish staff and initial training requirements.12024-03-19
E-0020Establish policies and procedures including evacuation.12024-03-19
K-0922Meet requirements for the use and maintenance of medical gas equipment.12024-03-19
E-0041Implement emergency and standby power systems.12024-03-19
K-0911Meet requirements for the installation and maintenance of electrical systems.12025-03-25

What the citations cover

Citations by CMS category
  • Miscellaneous Deficiencies 5
  • Emergency Preparedness Deficiencies 4
  • Smoke Deficiencies 4
  • Gas, Vacuum, and Electrical Systems Deficiencies 3
  • Other 1
Citations by CMS category
CategoryCitations
Miscellaneous Deficiencies5
Emergency Preparedness Deficiencies4
Smoke Deficiencies4
Gas, Vacuum, and Electrical Systems Deficiencies3
Egress Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

May 7, 2026 — 4 citations

Citations issued on May 7, 2026
TagWhat the surveyor checksStatus
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (June 30, 2026)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (June 30, 2026)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (June 30, 2026)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (June 30, 2026)

March 25, 2025 — 5 citations

Citations issued on March 25, 2025
TagWhat the surveyor checksStatus
K-0300Meet other general requirements that are deficient.Deficient, Provider has date of correction (April 2, 2025)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (April 18, 2025)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (April 18, 2025)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (April 18, 2025)
K-0911Meet requirements for the installation and maintenance of electrical systems.Deficient, Provider has date of correction (April 3, 2025)

March 19, 2024 — 8 citations

Citations issued on March 19, 2024
TagWhat the surveyor checksStatus
E-0020Establish policies and procedures including evacuation.Deficient, Provider has date of correction (May 3, 2024)
E-0024Establish policies and procedures for volunteers.Deficient, Provider has date of correction (May 3, 2024)
E-0037Establish staff and initial training requirements.Deficient, Provider has date of correction (May 3, 2024)
E-0041Implement emergency and standby power systems.Deficient, Provider has date of correction (May 3, 2024)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (May 3, 2024)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (May 3, 2024)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (May 3, 2024)
K-0922Meet requirements for the use and maintenance of medical gas equipment.Deficient, Provider has date of correction (May 3, 2024)