Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Old Mill Rehabilitation

Omaha, NE · 44 certified beds · Last Life Safety survey April 2, 2026

CMS Certification Number 285289 · first certified June 2014

Ownership

Operated by PROMONTORY HEALTHCARE MANAGEMENT · For profit - Corporation

No change of ownership on CMS record since January 1, 2016, when the records begin.

22
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
8
Tags cited more than once
Across separate surveys
11
Inspection & testing records
Of the citations on file

Position within NE

22 citations — more than 74% of the 180 certified nursing homes in NE. Compared within NE rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 3 citations; the earlier surveys in the window averaged 9.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens April 2027 — about 6 months from now. This facility’s last Life Safety survey was April 2026. Facilities in NE are typically surveyed 12–14 months after the last one (median 13), measured over 271 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about Old Mill Rehabilitation

One email when it happens. No account; stop it any time with one click.

Which alerts

4 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Emergency preparedness

2 of the 22 citations on file are Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

3 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 22 Life Safety citations above. The Physical Environment Index

  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0923 Have enough outside ventilation via a window or mechanical ventilation, or both.

How that compares

Citations on file over three years

Compared with the median facility in NE, and nationally. Surveyors differ markedly between states, so the NE figure is the meaningful one.

This facility22NE median15National median11
Citations on file over three years, compared
MeasureCitations
This facility22
Median facility in NE15
Median facility nationally11

Survey history

Citations at each Life Safety survey
102024-0492025-0432026-04
Citations at each Life Safety survey
Survey dateCitations
April 16, 202410
April 10, 20259
April 2, 20263

Most-cited tags

Most-cited tags at this facility
K-09203K-07123K-09182E-00412K-03632K-03212K-05112K-09212
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0920Ensure proper usage of power strips and extension cords.32026-04-02
K-0712Have simulated fire drills held at unexpected times.32026-04-02
K-0918Have generator or other power source capable of supplying service within 10 seconds.22025-04-10
E-0041Implement emergency and standby power systems.22025-04-10
K-0363Install corridor and hallway doors that block smoke.22025-04-10
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.22026-04-02
K-0511Have properly installed electrical wiring and gas equipment.22025-04-10
K-0921Ensure that testing and maintenance of electrical equipment is performed.22025-04-10

What the citations cover

Citations by CMS category
  • Gas, Vacuum, and Electrical Systems Deficiencies 8
  • Smoke Deficiencies 7
  • Miscellaneous Deficiencies 3
  • Emergency Preparedness Deficiencies 2
  • Other 2
Citations by CMS category
CategoryCitations
Gas, Vacuum, and Electrical Systems Deficiencies8
Smoke Deficiencies7
Miscellaneous Deficiencies3
Emergency Preparedness Deficiencies2
Services Deficiencies2

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

April 2, 2026 — 3 citations

Citations issued on April 2, 2026
TagWhat the surveyor checksStatus
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (April 23, 2026)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (April 23, 2026)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (April 23, 2026)

April 10, 2025 — 9 citations

Citations issued on April 10, 2025
TagWhat the surveyor checksStatus
E-0041Implement emergency and standby power systems.Deficient, Provider has date of correction (May 23, 2025)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (May 23, 2025)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (May 23, 2025)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (May 23, 2025)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (May 23, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (May 23, 2025)
K-0919Meet requirements for the use of electrical equipment.Deficient, Provider has date of correction (May 23, 2025)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (May 23, 2025)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (May 23, 2025)

April 16, 2024 — 10 citations

Citations issued on April 16, 2024
TagWhat the surveyor checksStatus
E-0041Implement emergency and standby power systems.Deficient, Provider has date of correction (May 22, 2024)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (May 22, 2024)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (May 22, 2024)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (May 22, 2024)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (May 22, 2024)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (May 22, 2024)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (May 22, 2024)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (May 22, 2024)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (May 22, 2024)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (May 22, 2024)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.