Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Omaha Nursing and Rehabilitation Center

Omaha, NE · 70 certified beds · Last Life Safety survey July 31, 2025

CMS Certification Number 285240 · first certified July 2001

Ownership

Operated by THE ENSIGN GROUP · For profit - Corporation

No change of ownership on CMS record since January 1, 2016, when the records begin.

10
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
1
Tags cited more than once
Across separate surveys
4
Inspection & testing records
Of the citations on file

Position within NE

10 citations — more than 28% of the 180 certified nursing homes in NE. Compared within NE rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 1 citation; the earlier surveys in the window averaged 4.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window is open now: July 2026 to October 2026. This facility’s last Life Safety survey was July 2025. Facilities in NE are typically surveyed 12–14 months after the last one (median 13), measured over 271 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about Omaha Nursing and Rehabilitation Center

One email when it happens. No account; stop it any time with one click.

Which alerts

Emergency preparedness

1 of the 10 citations on file is Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

12 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 10 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0908 Keep all essential equipment working safely.
  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.

How that compares

Citations on file over three years

Compared with the median facility in NE, and nationally. Surveyors differ markedly between states, so the NE figure is the meaningful one.

This facility10NE median15National median11
Citations on file over three years, compared
MeasureCitations
This facility10
Median facility in NE15
Median facility nationally11

Survey history

Citations at each Life Safety survey
62023-0532024-0612025-07
Citations at each Life Safety survey
Survey dateCitations
May 3, 20236
June 13, 20243
July 31, 20251

Most-cited tags

Most-cited tags at this facility
K-02222K-09221K-07121E-00411K-03451K-09181K-03741K-09201
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.22025-07-31
K-0922Meet requirements for the use and maintenance of medical gas equipment.12024-06-13
K-0712Have simulated fire drills held at unexpected times.12023-05-03
E-0041Implement emergency and standby power systems.12023-05-03
K-0345Have approved installation, maintenance and testing program for fire alarm systems.12023-05-03
K-0918Have generator or other power source capable of supplying service within 10 seconds.12023-05-03
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.12024-06-13
K-0920Ensure proper usage of power strips and extension cords.12024-06-13

What the citations cover

Citations by CMS category
  • Gas, Vacuum, and Electrical Systems Deficiencies 3
  • Smoke Deficiencies 3
  • Egress Deficiencies 2
  • Emergency Preparedness Deficiencies 1
  • Other 1
Citations by CMS category
CategoryCitations
Gas, Vacuum, and Electrical Systems Deficiencies3
Smoke Deficiencies3
Egress Deficiencies2
Emergency Preparedness Deficiencies1
Miscellaneous Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

July 31, 2025 — 1 citation

Citations issued on July 31, 2025
TagWhat the surveyor checksStatus
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (August 21, 2025)

June 13, 2024 — 3 citations

Citations issued on June 13, 2024
TagWhat the surveyor checksStatus
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (July 19, 2024)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (July 19, 2024)
K-0922Meet requirements for the use and maintenance of medical gas equipment.Deficient, Provider has date of correction (July 19, 2024)

May 3, 2023 — 6 citations

Citations issued on May 3, 2023
TagWhat the surveyor checksStatus
E-0041Implement emergency and standby power systems.Deficient, Provider has date of correction (May 31, 2023)
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (May 31, 2023)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (May 31, 2023)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (May 31, 2023)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (May 31, 2023)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (May 31, 2023)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.