Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Arbor Care Centers - Ord, LLC

Ord, NE · 60 certified beds · Last Life Safety survey November 18, 2025

CMS Certification Number 285294 · first certified July 2015

Ownership

Independently operated (no chain recorded by CMS) · For profit - Limited Liability company

  • Ownership changed November 1, 2020 (change of ownership)from VALLEY VIEW SENIOR VILLAGE LLC
9
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
4
Tags cited more than once
Across separate surveys
7
Inspection & testing records
Of the citations on file

Position within NE

9 citations — more than 21% of the 180 certified nursing homes in NE. Compared within NE rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 4 citations; the earlier surveys in the window averaged 2.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens November 2026 — about 2 months from now. This facility’s last Life Safety survey was November 2025. Facilities in NE are typically surveyed 12–14 months after the last one (median 13), measured over 271 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about Arbor Care Centers - Ord, LLC

One email when it happens. No account; stop it any time with one click.

Which alerts

3 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Emergency preparedness

2 of the 9 citations on file are Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

7 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 9 Life Safety citations above. The Physical Environment Index

  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0923 Have enough outside ventilation via a window or mechanical ventilation, or both.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0925 Make sure there is a pest control program to prevent/deal with mice, insects, or other pests.

How that compares

Citations on file over three years

Compared with the median facility in NE, and nationally. Surveyors differ markedly between states, so the NE figure is the meaningful one.

This facility9NE median15National median11
Citations on file over three years, compared
MeasureCitations
This facility9
Median facility in NE15
Median facility nationally11

Survey history

Citations at each Life Safety survey
32023-0822024-0842025-11
Citations at each Life Safety survey
Survey dateCitations
August 24, 20233
August 22, 20242
November 18, 20254

Most-cited tags

Most-cited tags at this facility
K-03633E-00412K-07122K-09182
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0363Install corridor and hallway doors that block smoke.32025-11-18
E-0041Implement emergency and standby power systems.22025-11-18
K-0712Have simulated fire drills held at unexpected times.22025-11-18
K-0918Have generator or other power source capable of supplying service within 10 seconds.22025-11-18

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 3
  • Gas, Vacuum, and Electrical Systems Deficiencies 2
  • Emergency Preparedness Deficiencies 2
  • Miscellaneous Deficiencies 2
Citations by CMS category
CategoryCitations
Smoke Deficiencies3
Gas, Vacuum, and Electrical Systems Deficiencies2
Emergency Preparedness Deficiencies2
Miscellaneous Deficiencies2

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

November 18, 2025 — 4 citations

Citations issued on November 18, 2025
TagWhat the surveyor checksStatus
E-0041Implement emergency and standby power systems.Deficient, Provider has date of correction (December 18, 2025)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (December 18, 2025)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (December 18, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (December 18, 2025)

August 22, 2024 — 2 citations

Citations issued on August 22, 2024
TagWhat the surveyor checksStatus
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (October 6, 2024)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (October 6, 2024)

August 24, 2023 — 3 citations

Citations issued on August 24, 2023
TagWhat the surveyor checksStatus
E-0041Implement emergency and standby power systems.Deficient, Provider has date of correction (October 8, 2023)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (October 8, 2023)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (October 8, 2023)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.