Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Prestige Care Center of Plattsmouth

Plattsmouth, NE · 111 certified beds · Last Life Safety survey April 2, 2026

CMS Certification Number 285104 · first certified April 1991

Ownership

Operated by PRESTIGE CARE CENTER · For profit - Limited Liability company

  • Ownership changed April 16, 2019 (change of ownership)from PLATTSMOUTH CARE AND REHABILITATION CENTER LLC
61
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
20
Tags cited more than once
Across separate surveys
23
Inspection & testing records
Of the citations on file

Position within NE

61 citations — more than 99% of the 180 certified nursing homes in NE. Compared within NE rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Holding steadyabout the same at the latest survey as at its earlier surveys in the window.

The latest survey found 20 citations; the earlier surveys in the window averaged 20.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens April 2027 — about 6 months from now. This facility’s last Life Safety survey was April 2026. Facilities in NE are typically surveyed 12–14 months after the last one (median 13), measured over 271 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about Prestige Care Center of Plattsmouth

One email when it happens. No account; stop it any time with one click.

Which alerts

8 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Emergency preparedness

2 of the 61 citations on file are Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

7 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 61 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0923 Have enough outside ventilation via a window or mechanical ventilation, or both.
  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.

How that compares

Citations on file over three years

Compared with the median facility in NE, and nationally. Surveyors differ markedly between states, so the NE figure is the meaningful one.

This facility61NE median15National median11
Citations on file over three years, compared
MeasureCitations
This facility61
Median facility in NE15
Median facility nationally11

Survey history

Citations at each Life Safety survey
242024-01172025-02202026-04
Citations at each Life Safety survey
Survey dateCitations
January 22, 202424
February 6, 202517
April 2, 202620

Most-cited tags

Most-cited tags at this facility
K-05003K-09203K-05113K-09183K-07123K-09193K-03633K-03213
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0500Meet other general requirements that are deficient.32026-04-02
K-0920Ensure proper usage of power strips and extension cords.32026-04-02
K-0511Have properly installed electrical wiring and gas equipment.32026-04-02
K-0918Have generator or other power source capable of supplying service within 10 seconds.32026-04-02
K-0712Have simulated fire drills held at unexpected times.32026-04-02
K-0919Meet requirements for the use of electrical equipment.32026-04-02
K-0363Install corridor and hallway doors that block smoke.32026-04-02
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.32026-04-02

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 16
  • Gas, Vacuum, and Electrical Systems Deficiencies 16
  • Egress Deficiencies 11
  • Miscellaneous Deficiencies 9
  • Other 9
Citations by CMS category
CategoryCitations
Smoke Deficiencies16
Gas, Vacuum, and Electrical Systems Deficiencies16
Egress Deficiencies11
Miscellaneous Deficiencies9
Services Deficiencies6
Emergency Preparedness Deficiencies2
Construction Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

April 2, 2026 — 20 citations

Citations issued on April 2, 2026
TagWhat the surveyor checksStatus
K-0200Meet other general requirements.Deficient, Provider has date of correction (April 30, 2026)
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (April 30, 2026)
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (April 30, 2026)
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (April 30, 2026)
K-0293Have properly located and lighted "Exit" signs.Deficient, Provider has date of correction (April 30, 2026)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (April 30, 2026)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (April 30, 2026)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (April 30, 2026)
K-0351Install an approved automatic sprinkler system.Deficient, Provider has date of correction (April 30, 2026)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (April 30, 2026)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (April 30, 2026)
K-0500Meet other general requirements that are deficient.Deficient, Provider has date of correction (April 30, 2026)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (April 30, 2026)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (April 30, 2026)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (April 30, 2026)
K-0900Meet Health Care Facilities Code mechanical requirements.Deficient, Provider has date of correction (April 30, 2026)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (April 30, 2026)
K-0919Meet requirements for the use of electrical equipment.Deficient, Provider has date of correction (April 30, 2026)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (April 30, 2026)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (May 27, 2026)

February 6, 2025 — 17 citations

Citations issued on February 6, 2025
TagWhat the surveyor checksStatus
E-0041Implement emergency and standby power systems.Deficient, Provider has date of correction (March 21, 2025)
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (April 12, 2025)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (April 12, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (March 21, 2025)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (March 21, 2025)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (April 12, 2025)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (March 21, 2025)
K-0500Meet other general requirements that are deficient.Deficient, Provider has date of correction (March 21, 2025)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (March 21, 2025)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (March 21, 2025)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (March 21, 2025)
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.Deficient, Provider has date of correction (March 21, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (March 21, 2025)
K-0919Meet requirements for the use of electrical equipment.Deficient, Provider has date of correction (March 21, 2025)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (March 21, 2025)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (March 21, 2025)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (March 21, 2025)

January 22, 2024 — 24 citations

Citations issued on January 22, 2024
TagWhat the surveyor checksStatus
E-0041Implement emergency and standby power systems.Deficient, Provider has date of correction (March 7, 2024)
K-0111Satisfy building requirements after a repair, renovation, modification, or change of user/occupancy.Deficient, Provider has date of correction (March 7, 2024)
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (March 7, 2024)
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (March 7, 2024)
K-0281Install proper backup exit lighting.Deficient, Provider has date of correction (March 7, 2024)
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (March 7, 2024)
K-0293Have properly located and lighted "Exit" signs.Deficient, Provider has date of correction (March 7, 2024)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (March 7, 2024)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (April 19, 2024)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (March 7, 2024)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (March 7, 2024)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (March 7, 2024)
K-0500Meet other general requirements that are deficient.Deficient, Provider has date of correction (March 7, 2024)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (March 7, 2024)
K-0700Meet requirements for operating features, such as evacuation plans, fire drills, smoking regulations, draperies, decorations and the inspection, testing and maintenance of fire doors.Deficient, Provider has date of correction (March 7, 2024)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (March 7, 2024)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (March 7, 2024)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (March 7, 2024)
K-0914Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.Deficient, Provider has date of correction (March 7, 2024)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (March 7, 2024)
K-0919Meet requirements for the use of electrical equipment.Deficient, Provider has date of correction (March 7, 2024)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (March 7, 2024)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (March 7, 2024)
K-0922Meet requirements for the use and maintenance of medical gas equipment.Deficient, Provider has date of correction (March 7, 2024)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.