Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

JEWISH HOME FOR REHABILITATION AND NURSING, THE

FREEHOLD, NJ · 150 certified beds · Last Life Safety survey June 3, 2025

CMS Certification Number 315528 · first certified December 2018

Ownership

Independently operated (no chain recorded by CMS) · For profit - Limited Liability company

  • Ownership changed May 1, 2020 (change of ownership)to THE JEWISH HOME FOR REHABILITATION AND NURSING from THE JEWISH HOME FOR REHABILITATION AND NURSING INC
17
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
2
Tags cited more than once
Across separate surveys
7
Inspection & testing records
Of the citations on file

Position within NJ

17 citations — more than 59% of the 348 certified nursing homes in NJ. Compared within NJ rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 15 citations; the earlier surveys in the window averaged 1. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window is open now: September 2026 to February 2027. This facility’s last Life Safety survey was June 2025. Facilities in NJ are typically surveyed 16–20 months after the last one (median 17), measured over 431 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about JEWISH HOME FOR REHABILITATION AND NURSING, THE

One email when it happens. No account; stop it any time with one click.

Which alerts

1 inspection-and-testing tag has been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Emergency preparedness

1 of the 17 citations on file is Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

2 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 17 Life Safety citations above. The Physical Environment Index

  • F-0880 Provide and implement an infection prevention and control program.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.

How that compares

Citations on file over three years

Compared with the median facility in NJ, and nationally. Surveyors differ markedly between states, so the NJ figure is the meaningful one.

This facility17NJ median15National median11
Citations on file over three years, compared
MeasureCitations
This facility17
Median facility in NJ15
Median facility nationally11

Survey history

Citations at each Life Safety survey
22021-0702023-05152025-06
Citations at each Life Safety survey
Survey dateCitations
July 9, 20212
May 2, 20230
June 3, 202515

Most-cited tags

Most-cited tags at this facility
K-03212K-02912K-02231K-09121K-03631K-02251K-09211K-07611
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.22025-06-03
K-0291Install emergency lighting that can last at least 1 1/2 hours.22025-06-03
K-0223Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.12025-06-03
K-0912Have power receptacles that are properly grounded.12025-06-03
K-0363Install corridor and hallway doors that block smoke.12025-06-03
K-0225Have stairways and smokeproof enclosures used as exits that meet safety requirements.12025-06-03
K-0921Ensure that testing and maintenance of electrical equipment is performed.12025-06-03
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.12025-06-03

What the citations cover

Citations by CMS category
  • Egress Deficiencies 6
  • Smoke Deficiencies 6
  • Gas, Vacuum, and Electrical Systems Deficiencies 2
  • Miscellaneous Deficiencies 2
  • Other 1
Citations by CMS category
CategoryCitations
Egress Deficiencies6
Smoke Deficiencies6
Gas, Vacuum, and Electrical Systems Deficiencies2
Miscellaneous Deficiencies2
Emergency Preparedness Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

June 3, 2025 — 15 citations

Citations issued on June 3, 2025
TagWhat the surveyor checksStatus
E-0041Implement emergency and standby power systems.Deficient, Provider has date of correction (June 9, 2025)
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (June 25, 2025)
K-0223Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.Deficient, Provider has date of correction (June 9, 2025)
K-0225Have stairways and smokeproof enclosures used as exits that meet safety requirements.Deficient, Provider has date of correction (July 1, 2025)
K-0281Install proper backup exit lighting.Deficient, Provider has date of correction (July 21, 2025)
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (July 21, 2025)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (July 1, 2025)
K-0341Install a fire alarm system that can be heard throughout the facility.Deficient, Provider has date of correction (July 21, 2025)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (June 16, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (June 12, 2025)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (July 21, 2025)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (June 3, 2025)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (July 21, 2025)
K-0912Have power receptacles that are properly grounded.Deficient, Provider has date of correction (June 5, 2025)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (July 21, 2025)

July 9, 2021 — 2 citations

Citations issued on July 9, 2021
TagWhat the surveyor checksStatus
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (July 20, 2021)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (July 20, 2021)