Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

FOLTSBROOK CENTER FOR NURSING AND REHABILITATION

HERKIMER, NY · 163 certified beds · Last Life Safety survey January 29, 2025

CMS Certification Number 335510 · first certified March 1976

Ownership

Operated by WECARE CENTERS · For profit - Corporation

  • Ownership changed July 1, 2018 (change of ownership)from HOMELIFE AT FOLTS LLC
32
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
8
Tags cited more than once
Across separate surveys
12
Inspection & testing records
Of the citations on file

Position within NY

32 citations — more than 94% of the 593 certified nursing homes in NY. Compared within NY rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 16 citations; the earlier surveys in the window averaged 8. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window is open now: July 2026 to March 2027. This facility’s last Life Safety survey was January 2025. Facilities in NY are typically surveyed 18–25 months after the last one (median 22), measured over 523 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about FOLTSBROOK CENTER FOR NURSING AND REHABILITATION

One email when it happens. No account; stop it any time with one click.

Which alerts

3 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Emergency preparedness

1 of the 32 citations on file is Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

6 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 32 Life Safety citations above. The Physical Environment Index

  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0925 Make sure there is a pest control program to prevent/deal with mice, insects, or other pests.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.

How that compares

Citations on file over three years

Compared with the median facility in NY, and nationally. Surveyors differ markedly between states, so the NY figure is the meaningful one.

This facility32NY median13National median11
Citations on file over three years, compared
MeasureCitations
This facility32
Median facility in NY13
Median facility nationally11

Survey history

Citations at each Life Safety survey
62021-06102023-06162025-01
Citations at each Life Safety survey
Survey dateCitations
June 9, 20216
June 30, 202310
January 29, 202516

Most-cited tags

Most-cited tags at this facility
K-01333K-03113K-03512K-03632K-09182K-09272K-09212K-03532
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0133Install a two-hour-resistant firewall separation.32025-01-29
K-0311Have an enclosure around a vertical opening shaft.32025-01-29
K-0351Install an approved automatic sprinkler system.22023-06-30
K-0363Install corridor and hallway doors that block smoke.22025-01-29
K-0918Have generator or other power source capable of supplying service within 10 seconds.22025-01-29
K-0927Have proper fire barriers, ventilation and signs for the transfilling of oxygen.22025-01-29
K-0921Ensure that testing and maintenance of electrical equipment is performed.22025-01-29
K-0353Inspect, test, and maintain automatic sprinkler systems.22025-01-29

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 14
  • Gas, Vacuum, and Electrical Systems Deficiencies 8
  • Egress Deficiencies 4
  • Construction Deficiencies 3
  • Other 3
Citations by CMS category
CategoryCitations
Smoke Deficiencies14
Gas, Vacuum, and Electrical Systems Deficiencies8
Egress Deficiencies4
Construction Deficiencies3
Emergency Preparedness Deficiencies1
Miscellaneous Deficiencies1
Services Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

January 29, 2025 — 16 citations

Citations issued on January 29, 2025
TagWhat the surveyor checksStatus
E-0015Address subsistence needs for staff and patients.Deficient, Provider has date of correction (March 30, 2025)
K-0133Install a two-hour-resistant firewall separation.Deficient, Provider has date of correction (March 30, 2025)
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (March 30, 2025)
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (March 30, 2025)
K-0271Have exits that are accessible at all times.Deficient, Provider has date of correction (March 30, 2025)
K-0311Have an enclosure around a vertical opening shaft.Deficient, Provider has date of correction (March 30, 2025)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (March 30, 2025)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (March 30, 2025)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (March 30, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (March 30, 2025)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (March 30, 2025)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (March 30, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (March 30, 2025)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (March 30, 2025)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (March 30, 2025)
K-0927Have proper fire barriers, ventilation and signs for the transfilling of oxygen.Deficient, Provider has date of correction (March 30, 2025)

June 30, 2023 — 10 citations

Citations issued on June 30, 2023
TagWhat the surveyor checksStatus
K-0133Install a two-hour-resistant firewall separation.Deficient, Provider has date of correction (August 20, 2023)
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (August 20, 2023)
K-0311Have an enclosure around a vertical opening shaft.Deficient, Provider has date of correction (August 20, 2023)
K-0351Install an approved automatic sprinkler system.Deficient, Provider has date of correction (August 21, 2023)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (August 20, 2023)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (August 20, 2023)
K-0531Have elevators that firefighters can control in the event of a fire.Deficient, Provider has date of correction (August 20, 2023)
K-0916Have a battery powered remote alarm panel in a location accessible by operating personnel.Deficient, Provider has date of correction (August 20, 2023)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (August 20, 2023)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (August 20, 2023)

June 9, 2021 — 6 citations

Citations issued on June 9, 2021
TagWhat the surveyor checksStatus
K-0133Install a two-hour-resistant firewall separation.Deficient, Provider has date of correction (June 28, 2021)
K-0311Have an enclosure around a vertical opening shaft.Deficient, Provider has date of correction (June 28, 2021)
K-0351Install an approved automatic sprinkler system.Deficient, Provider has date of correction (June 28, 2021)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (June 28, 2021)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (June 28, 2021)
K-0927Have proper fire barriers, ventilation and signs for the transfilling of oxygen.Deficient, Provider has date of correction (June 28, 2021)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.