Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Sullivan County Adult Care Center

Liberty, NY · 146 certified beds · Last Life Safety survey September 27, 2024

CMS Certification Number 335628 · first certified April 1978

Ownership

Independently operated (no chain recorded by CMS) · Government - County

No change of ownership on CMS record since January 1, 2016, when the records begin.

32
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
9
Tags cited more than once
Across separate surveys
13
Inspection & testing records
Of the citations on file

Position within NY

32 citations — more than 94% of the 593 certified nursing homes in NY. Compared within NY rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 12 citations; the earlier surveys in the window averaged 10. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window is open now: March 2026 to November 2026. This facility’s last Life Safety survey was September 2024. Facilities in NY are typically surveyed 18–25 months after the last one (median 22), measured over 523 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about Sullivan County Adult Care Center

One email when it happens. No account; stop it any time with one click.

Which alerts

4 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Emergency preparedness

7 of the 32 citations on file are Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

5 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 32 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0880 Provide and implement an infection prevention and control program.

How that compares

Citations on file over three years

Compared with the median facility in NY, and nationally. Surveyors differ markedly between states, so the NY figure is the meaningful one.

This facility32NY median13National median11
Citations on file over three years, compared
MeasureCitations
This facility32
Median facility in NY13
Median facility nationally11

Survey history

Citations at each Life Safety survey
132019-0972023-01122024-09
Citations at each Life Safety survey
Survey dateCitations
September 4, 201913
January 5, 20237
September 27, 202412

Most-cited tags

Most-cited tags at this facility
K-07123K-09182K-03212K-09212K-03532K-02812E-00132K-03242
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0712Have simulated fire drills held at unexpected times.32024-09-27
K-0918Have generator or other power source capable of supplying service within 10 seconds.22024-09-27
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.22023-01-05
K-0921Ensure that testing and maintenance of electrical equipment is performed.22024-09-27
K-0353Inspect, test, and maintain automatic sprinkler systems.22023-01-05
K-0281Install proper backup exit lighting.22024-09-27
E-0013Develop Emergency Preparedness policies and procedures.22023-01-05
K-0324Provide properly protected cooking facilities.22024-09-27

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 9
  • Emergency Preparedness Deficiencies 7
  • Gas, Vacuum, and Electrical Systems Deficiencies 5
  • Services Deficiencies 3
  • Other 8
Citations by CMS category
CategoryCitations
Smoke Deficiencies9
Emergency Preparedness Deficiencies7
Gas, Vacuum, and Electrical Systems Deficiencies5
Services Deficiencies3
Egress Deficiencies3
Miscellaneous Deficiencies3
Electrical Deficiencies1
Construction Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

September 27, 2024 — 12 citations

Citations issued on September 27, 2024
TagWhat the surveyor checksStatus
K-0161Use approved construction type or materials.Deficient, Provider has date of correction (December 9, 2024)
K-0281Install proper backup exit lighting.Deficient, Provider has date of correction (October 13, 2024)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (December 9, 2024)
K-0351Install an approved automatic sprinkler system.Deficient, Provider has date of correction (December 9, 2024)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (December 9, 2024)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (November 1, 2024)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (December 9, 2024)
K-0531Have elevators that firefighters can control in the event of a fire.Deficient, Provider has date of correction (December 9, 2024)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (November 26, 2024)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (December 9, 2024)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (December 4, 2024)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (December 9, 2024)

January 5, 2023 — 7 citations

Citations issued on January 5, 2023
TagWhat the surveyor checksStatus
E-0013Develop Emergency Preparedness policies and procedures.Deficient, Provider has date of correction (March 5, 2023)
E-0039Conduct testing and exercise requirements.Deficient, Provider has date of correction (March 5, 2023)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (March 5, 2023)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (March 5, 2023)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (March 5, 2023)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (March 5, 2023)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (March 5, 2023)

September 4, 2019 — 13 citations

Citations issued on September 4, 2019
TagWhat the surveyor checksStatus
E-0013Develop Emergency Preparedness policies and procedures.Deficient, Provider has date of correction (October 24, 2019)
E-0034Provide a means of sharing information on occupancy/needs.Deficient, Provider has date of correction (October 24, 2019)
E-0036Establish emergency prep training and testing.Deficient, Provider has date of correction (October 24, 2019)
E-0039Conduct testing and exercise requirements.Deficient, Provider has date of correction (October 24, 2019)
E-0041Implement emergency and standby power systems.Deficient, Provider has date of correction (October 24, 2019)
K-0225Have stairways and smokeproof enclosures used as exits that meet safety requirements.Deficient, Provider has date of correction (October 24, 2019)
K-0281Install proper backup exit lighting.Deficient, Provider has date of correction (October 24, 2019)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (October 24, 2019)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (October 24, 2019)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (October 24, 2019)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (October 24, 2019)
K-0901Ensure that building systems meet requirements determined by risk assessment procedures performed by qualified personnel.Deficient, Provider has date of correction (October 24, 2019)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (October 24, 2019)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.