Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

VISTA CENTER AT THE RIDGE

MINERAL RIDGE, OH · 155 certified beds · Last Life Safety survey February 6, 2025

CMS Certification Number 365823 · first certified November 1990

Ownership

Operated by CONTINUING HEALTHCARE SOLUTIONS · For profit - Corporation

  • Ownership changed January 1, 2016 (change of ownership)to CONTINUING HEALTHCARE AT THE RIDGE from VISTA CARE CENTER OF MINERAL RIDGE LLC
29
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
5
Tags cited more than once
Across separate surveys
8
Inspection & testing records
Of the citations on file

Position within OH

29 citations — more than 85% of the 922 certified nursing homes in OH. Compared within OH rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 6 citations; the earlier surveys in the window averaged 11.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens October 2026. This facility’s last Life Safety survey was February 2025. Facilities in OH are typically surveyed 20–32 months after the last one (median 26), measured over 889 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about VISTA CENTER AT THE RIDGE

One email when it happens. No account; stop it any time with one click.

Which alerts

1 inspection-and-testing tag has been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

6 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 29 Life Safety citations above. The Physical Environment Index

  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0921 Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0925 Make sure there is a pest control program to prevent/deal with mice, insects, or other pests.
  • F-0919 Make sure that a working call system is available in each resident's bathroom and bathing area.

How that compares

Citations on file over three years

Compared with the median facility in OH, and nationally. Surveyors differ markedly between states, so the OH figure is the meaningful one.

This facility29OH median16National median11
Citations on file over three years, compared
MeasureCitations
This facility29
Median facility in OH16
Median facility nationally11

Survey history

Citations at each Life Safety survey
172020-0162023-0162025-02
Citations at each Life Safety survey
Survey dateCitations
January 30, 202017
January 12, 20236
February 6, 20256

Most-cited tags

Most-cited tags at this facility
K-02222K-07812K-03212K-07412K-05112K-05001K-01611K-09181
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.22025-02-06
K-0781Have restrictions on the use of portable space heaters.22025-02-06
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.22023-01-12
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.22025-02-06
K-0511Have properly installed electrical wiring and gas equipment.22025-02-06
K-0500Meet other general requirements that are deficient.12023-01-12
K-0161Use approved construction type or materials.12020-01-30
K-0918Have generator or other power source capable of supplying service within 10 seconds.12020-01-30

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 11
  • Egress Deficiencies 6
  • Miscellaneous Deficiencies 5
  • Services Deficiencies 3
  • Other 4
Citations by CMS category
CategoryCitations
Smoke Deficiencies11
Egress Deficiencies6
Miscellaneous Deficiencies5
Services Deficiencies3
Gas, Vacuum, and Electrical Systems Deficiencies2
Construction Deficiencies2

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

February 6, 2025 — 6 citations

Citations issued on February 6, 2025
TagWhat the surveyor checksStatus
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (March 6, 2025)
K-0223Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.Deficient, Provider has date of correction (March 6, 2025)
K-0361Ensure that waiting areas, nurse’s stations, gift shops, and cooking facilities, open to the corridor are properly protected.Deficient, Provider has date of correction (March 6, 2025)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (March 6, 2025)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (March 6, 2025)
K-0781Have restrictions on the use of portable space heaters.Deficient, Provider has date of correction (March 6, 2025)

January 12, 2023 — 6 citations

Citations issued on January 12, 2023
TagWhat the surveyor checksStatus
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (February 23, 2023)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (February 23, 2023)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (February 23, 2023)
K-0500Meet other general requirements that are deficient.Deficient, Provider has date of correction (February 23, 2023)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (February 23, 2023)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (February 23, 2023)

January 30, 2020 — 17 citations

Citations issued on January 30, 2020
TagWhat the surveyor checksStatus
K-0133Install a two-hour-resistant firewall separation.Deficient, Provider has date of correction (March 19, 2020)
K-0161Use approved construction type or materials.Deficient, Provider has date of correction (March 19, 2020)
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (March 19, 2020)
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (March 19, 2020)
K-0227Have ramps, exits, fire escape ladders, steps, and areas of refuge that meet safety requirements.Deficient, Provider has date of correction (March 19, 2020)
K-0241Have correct number of accessible exits for each story.Deficient, Provider has date of correction (March 19, 2020)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (March 19, 2020)
K-0341Install a fire alarm system that can be heard throughout the facility.Deficient, Provider has date of correction (March 19, 2020)
K-0347Properly provide smoke detection systems in areas open to corridors.Deficient, Provider has date of correction (March 19, 2020)
K-0351Install an approved automatic sprinkler system.Deficient, Provider has date of correction (March 19, 2020)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (March 19, 2020)
K-0363Install corridor and hallway doors that block smoke.Waiver has been granted (September 30, 2020)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (March 19, 2020)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (March 19, 2020)
K-0781Have restrictions on the use of portable space heaters.Deficient, Provider has date of correction (March 19, 2020)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (March 19, 2020)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (March 19, 2020)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.