Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

CARRIAGE INN OF STEUBENVILLE

STEUBENVILLE, OH · 120 certified beds · Last Life Safety survey April 6, 2026

CMS Certification Number 365271 · first certified March 1979

Ownership

Independently operated (no chain recorded by CMS) · For profit - Limited Liability company

No change of ownership on CMS record since January 1, 2016, when the records begin.

20
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
5
Tags cited more than once
Across separate surveys
14
Inspection & testing records
Of the citations on file

Position within OH

20 citations — more than 64% of the 922 certified nursing homes in OH. Compared within OH rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Holding steadyabout the same at the latest survey as at its earlier surveys in the window.

The latest survey found 7 citations; the earlier surveys in the window averaged 6.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens November 2027 — about 14 months from now. This facility’s last Life Safety survey was April 2026. Facilities in OH are typically surveyed 20–32 months after the last one (median 26), measured over 889 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about CARRIAGE INN OF STEUBENVILLE

One email when it happens. No account; stop it any time with one click.

Which alerts

5 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

5 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 20 Life Safety citations above. The Physical Environment Index

  • F-0921 Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.

How that compares

Citations on file over three years

Compared with the median facility in OH, and nationally. Surveyors differ markedly between states, so the OH figure is the meaningful one.

This facility20OH median16National median11
Citations on file over three years, compared
MeasureCitations
This facility20
Median facility in OH16
Median facility nationally11

Survey history

Citations at each Life Safety survey
22022-05112024-0372026-04
Citations at each Life Safety survey
Survey dateCitations
May 19, 20222
March 13, 202411
April 6, 20267

Most-cited tags

Most-cited tags at this facility
K-07122K-03532K-05112K-03242K-03722K-03211K-02221K-05211
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0712Have simulated fire drills held at unexpected times.22024-03-13
K-0353Inspect, test, and maintain automatic sprinkler systems.22026-04-06
K-0511Have properly installed electrical wiring and gas equipment.22026-04-06
K-0324Provide properly protected cooking facilities.22026-04-06
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.22026-04-06
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.12024-03-13
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.12024-03-13
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.12026-04-06

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 10
  • Egress Deficiencies 4
  • Services Deficiencies 3
  • Miscellaneous Deficiencies 2
  • Other 1
Citations by CMS category
CategoryCitations
Smoke Deficiencies10
Egress Deficiencies4
Services Deficiencies3
Miscellaneous Deficiencies2
Construction Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

April 6, 2026 — 7 citations

Citations issued on April 6, 2026
TagWhat the surveyor checksStatus
K-0291Install emergency lighting that can last at least 1 1/2 hours.Deficient, Provider has date of correction (April 28, 2026)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (April 28, 2026)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (April 28, 2026)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (April 28, 2026)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (April 28, 2026)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (April 28, 2026)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (April 28, 2026)

March 13, 2024 — 11 citations

Citations issued on March 13, 2024
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Fire Safety Evaluation Survey (May 17, 2024)
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (May 17, 2024)
K-0271Have exits that are accessible at all times.Deficient, Provider has date of correction (May 17, 2024)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (May 17, 2024)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (May 17, 2024)
K-0351Install an approved automatic sprinkler system.Deficient, Provider has date of correction (May 17, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (May 17, 2024)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (May 17, 2024)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (May 17, 2024)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (May 17, 2024)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (May 17, 2024)

May 19, 2022 — 2 citations

Citations issued on May 19, 2022
TagWhat the surveyor checksStatus
K-0131Meet requirements for sections of health care facilities separated by fire resistive construction.Deficient, Provider has date of correction (June 10, 2022)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (June 10, 2022)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.