Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

WALNUT CREEK NURSING AND REHAB

ERIE, PA · 115 certified beds · Last Life Safety survey May 14, 2026

CMS Certification Number 395200 · first certified January 1967

Ownership

Operated by VALLEY WEST HEALTH · For profit - Limited Liability company

  • New ownershipOwnership changed October 29, 2024 (change of ownership)from GUARDIAN ELDER CARE AT ERIE II LLC
7
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
0
Tags cited more than once
Across separate surveys
5
Inspection & testing records
Of the citations on file

Position within PA

7 citations — more than 35% of the 656 certified nursing homes in PA. Compared within PA rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 3 citations; the earlier surveys in the window averaged 2. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens March 2027 — about 6 months from now. This facility’s last Life Safety survey was May 2026. Facilities in PA are typically surveyed 10–12 months after the last one (median 11), measured over 1,113 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about WALNUT CREEK NURSING AND REHAB

One email when it happens. No account; stop it any time with one click.

Which alerts

Physical environment (health survey)

2 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 7 Life Safety citations above. The Physical Environment Index

  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.

How that compares

Citations on file over three years

Compared with the median facility in PA, and nationally. Surveyors differ markedly between states, so the PA figure is the meaningful one.

This facility7PA median10National median11
Citations on file over three years, compared
MeasureCitations
This facility7
Median facility in PA10
Median facility nationally11

Survey history

Citations at each Life Safety survey
32024-0612025-0532026-05
Citations at each Life Safety survey
Survey dateCitations
June 28, 20243
May 22, 20251
May 14, 20263

Most-cited tags

Most-cited tags at this facility
K-07411K-03241K-05211K-07611K-03531K-03451K-02931
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.12026-05-14
K-0324Provide properly protected cooking facilities.12024-06-28
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.12026-05-14
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.12025-05-22
K-0353Inspect, test, and maintain automatic sprinkler systems.12024-06-28
K-0345Have approved installation, maintenance and testing program for fire alarm systems.12026-05-14
K-0293Have properly located and lighted "Exit" signs.12024-06-28

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 3
  • Miscellaneous Deficiencies 2
  • Egress Deficiencies 1
  • Services Deficiencies 1
Citations by CMS category
CategoryCitations
Smoke Deficiencies3
Miscellaneous Deficiencies2
Egress Deficiencies1
Services Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

May 14, 2026 — 3 citations

Citations issued on May 14, 2026
TagWhat the surveyor checksStatus
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (July 16, 2026)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (July 16, 2026)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (July 16, 2026)

May 22, 2025 — 1 citation

Citations issued on May 22, 2025
TagWhat the surveyor checksStatus
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has plan of correction (June 25, 2025)

June 28, 2024 — 3 citations

Citations issued on June 28, 2024
TagWhat the surveyor checksStatus
K-0293Have properly located and lighted "Exit" signs.Deficient, Provider has date of correction (July 29, 2024)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (July 29, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (July 29, 2024)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.