Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

ETOWAH HEALTH AND REHABILITATION

ETOWAH, TN · 120 certified beds · Last Life Safety survey February 25, 2026

CMS Certification Number 445422 · first certified December 2000

Ownership

Independently operated (no chain recorded by CMS) · For profit - Corporation

No change of ownership on CMS record since January 1, 2016, when the records begin.

14
Citations on file
Rolling three-year window
4
Life Safety surveys
In the same window
3
Tags cited more than once
Across separate surveys
7
Inspection & testing records
Of the citations on file

Position within TN

14 citations — more than 77% of the 303 certified nursing homes in TN. Compared within TN rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 5 citations; the earlier surveys in the window averaged 3. With 4 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens May 2027 — about 8 months from now. This facility’s last Life Safety survey was February 2026. Facilities in TN are typically surveyed 15–44 months after the last one (median 33), measured over 279 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about ETOWAH HEALTH AND REHABILITATION

One email when it happens. No account; stop it any time with one click.

Which alerts

2 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

5 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 14 Life Safety citations above. The Physical Environment Index

  • F-0880 Provide and implement an infection prevention and control program.
  • F-0921 Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.

How that compares

Citations on file over three years

Compared with the median facility in TN, and nationally. Surveyors differ markedly between states, so the TN figure is the meaningful one.

This facility14TN median8National median11
Citations on file over three years, compared
MeasureCitations
This facility14
Median facility in TN8
Median facility nationally11

Survey history

Citations at each Life Safety survey
22019-0642022-0632025-0852026-02
Citations at each Life Safety survey
Survey dateCitations
June 26, 20192
June 23, 20224
August 19, 20253
February 25, 20265

Most-cited tags

Most-cited tags at this facility
K-07122K-09182K-09112K-03541K-03461K-09211K-03631K-05211
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0712Have simulated fire drills held at unexpected times.22026-02-25
K-0918Have generator or other power source capable of supplying service within 10 seconds.22026-02-25
K-0911Meet requirements for the installation and maintenance of electrical systems.22026-02-25
K-0354Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours.12025-08-19
K-0346Follow proper procedures when the fire alarm was out of service for more than 4 hours.12025-08-19
K-0921Ensure that testing and maintenance of electrical equipment is performed.12019-06-26
K-0363Install corridor and hallway doors that block smoke.12026-02-25
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.12026-02-25

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 5
  • Gas, Vacuum, and Electrical Systems Deficiencies 5
  • Miscellaneous Deficiencies 2
  • Construction Deficiencies 1
  • Other 1
Citations by CMS category
CategoryCitations
Smoke Deficiencies5
Gas, Vacuum, and Electrical Systems Deficiencies5
Miscellaneous Deficiencies2
Construction Deficiencies1
Services Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

February 25, 2026 — 5 citations

Citations issued on February 25, 2026
TagWhat the surveyor checksStatus
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (April 5, 2026)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (April 5, 2026)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (April 5, 2026)
K-0911Meet requirements for the installation and maintenance of electrical systems.Deficient, Provider has date of correction (April 5, 2026)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (April 5, 2026)

August 19, 2025 — 3 citations

Citations issued on August 19, 2025
TagWhat the surveyor checksStatus
K-0343Have a fire alarm with audible and visual signals that transmits the alarm automatically to notify emergency forces in event of fire.Deficient, Provider has date of correction (September 4, 2025)
K-0346Follow proper procedures when the fire alarm was out of service for more than 4 hours.Deficient, Provider has date of correction (September 4, 2025)
K-0354Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours.Deficient, Provider has date of correction (September 4, 2025)

June 23, 2022 — 4 citations

Citations issued on June 23, 2022
TagWhat the surveyor checksStatus
K-0111Satisfy building requirements after a repair, renovation, modification, or change of user/occupancy.Deficient, Provider has date of correction (August 7, 2022)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (August 7, 2022)
K-0911Meet requirements for the installation and maintenance of electrical systems.Deficient, Provider has date of correction (August 7, 2022)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (August 7, 2022)

June 26, 2019 — 2 citations

Citations issued on June 26, 2019
TagWhat the surveyor checksStatus
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (August 10, 2019)
K-0921Ensure that testing and maintenance of electrical equipment is performed.Deficient, Provider has date of correction (August 10, 2019)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.