Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

FOOTHILLS TRANSITIONAL CARE AND REHABILITATION

MARYVILLE, TN · 185 certified beds · Last Life Safety survey January 10, 2024

CMS Certification Number 445245 · first certified March 1990

Ownership

Operated by THE ENSIGN GROUP · For profit - Corporation

  • Ownership changed May 1, 2024 (change of ownership)from MARYVILLE JAMESTOWN OPCO LLC
5
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
1
Tags cited more than once
Across separate surveys
1
Inspection & testing records
Of the citations on file

Position within TN

5 citations — more than 27% of the 303 certified nursing homes in TN. Compared within TN rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 3 citations; the earlier surveys in the window averaged 1. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window is open now: April 2025 to September 2027. This facility’s last Life Safety survey was January 2024. Facilities in TN are typically surveyed 15–44 months after the last one (median 33), measured over 279 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about FOOTHILLS TRANSITIONAL CARE AND REHABILITATION

One email when it happens. No account; stop it any time with one click.

Which alerts

Physical environment (health survey)

6 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 5 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0908 Keep all essential equipment working safely.
  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0919 Make sure that a working call system is available in each resident's bathroom and bathing area.

How that compares

Citations on file over three years

Compared with the median facility in TN, and nationally. Surveyors differ markedly between states, so the TN figure is the meaningful one.

This facility5TN median8National median11
Citations on file over three years, compared
MeasureCitations
This facility5
Median facility in TN8
Median facility nationally11

Survey history

Citations at each Life Safety survey
12019-0112020-0232024-01
Citations at each Life Safety survey
Survey dateCitations
January 16, 20191
February 12, 20201
January 10, 20243

Most-cited tags

Most-cited tags at this facility
K-07112K-02811K-03241K-03211
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0711Provide a written emergency evacuation plan.22024-01-10
K-0281Install proper backup exit lighting.12020-02-12
K-0324Provide properly protected cooking facilities.12024-01-10
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.12024-01-10

What the citations cover

Citations by CMS category
  • Miscellaneous Deficiencies 2
  • Smoke Deficiencies 2
  • Egress Deficiencies 1
Citations by CMS category
CategoryCitations
Miscellaneous Deficiencies2
Smoke Deficiencies2
Egress Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

January 10, 2024 — 3 citations

Citations issued on January 10, 2024
TagWhat the surveyor checksStatus
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (February 13, 2024)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (February 1, 2024)
K-0711Provide a written emergency evacuation plan.Deficient, Provider has date of correction (February 1, 2024)

February 12, 2020 — 1 citation

Citations issued on February 12, 2020
TagWhat the surveyor checksStatus
K-0281Install proper backup exit lighting.Deficient, Provider has date of correction (March 13, 2020)

January 16, 2019 — 1 citation

Citations issued on January 16, 2019
TagWhat the surveyor checksStatus
K-0711Provide a written emergency evacuation plan.Deficient, Provider has date of correction (January 15, 2019)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.