Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

CONCHO HEALTH & REHABILITATION CENTER

EDEN, TX · 66 certified beds · Last Life Safety survey July 24, 2025

CMS Certification Number 455737 · first certified February 1988

Ownership

Operated by CREATIVE SOLUTIONS IN HEALTHCARE · Government - Hospital district

  • Ownership changed September 1, 2022 (change of ownership)to CONCHO HEALTH AND REHABILITATION CENTER from VAL VERDE COUNTY HOSPITAL DISTRICT
14
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
3
Tags cited more than once
Across separate surveys
7
Inspection & testing records
Of the citations on file

Position within TX

14 citations — more than 83% of the 1,177 certified nursing homes in TX. Compared within TX rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 3 citations; the earlier surveys in the window averaged 5.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window is open now: September 2026 to October 2026. This facility’s last Life Safety survey was July 2025. Facilities in TX are typically surveyed 13–14 months after the last one (median 14), measured over 1,905 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about CONCHO HEALTH & REHABILITATION CENTER

One email when it happens. No account; stop it any time with one click.

Which alerts

2 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

5 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 14 Life Safety citations above. The Physical Environment Index

  • F-0880 Provide and implement an infection prevention and control program.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0908 Keep all essential equipment working safely.

How that compares

Citations on file over three years

Compared with the median facility in TX, and nationally. Surveyors differ markedly between states, so the TX figure is the meaningful one.

This facility14TX median7National median11
Citations on file over three years, compared
MeasureCitations
This facility14
Median facility in TX7
Median facility nationally11

Survey history

Citations at each Life Safety survey
72023-0442024-0532025-07
Citations at each Life Safety survey
Survey dateCitations
April 12, 20237
May 23, 20244
July 24, 20253

Most-cited tags

Most-cited tags at this facility
K-03723K-07412K-05212K-03211K-05111K-03511K-09201K-02111
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.32025-07-24
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.22025-07-24
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.22025-07-24
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.12024-05-23
K-0511Have properly installed electrical wiring and gas equipment.12023-04-12
K-0351Install an approved automatic sprinkler system.12023-04-12
K-0920Ensure proper usage of power strips and extension cords.12023-04-12
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.12023-04-12

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 6
  • Services Deficiencies 3
  • Egress Deficiencies 2
  • Miscellaneous Deficiencies 2
  • Other 1
Citations by CMS category
CategoryCitations
Smoke Deficiencies6
Services Deficiencies3
Egress Deficiencies2
Miscellaneous Deficiencies2
Gas, Vacuum, and Electrical Systems Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

July 24, 2025 — 3 citations

Citations issued on July 24, 2025
TagWhat the surveyor checksStatus
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (August 9, 2025)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (August 9, 2025)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (August 9, 2025)

May 23, 2024 — 4 citations

Citations issued on May 23, 2024
TagWhat the surveyor checksStatus
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (May 23, 2024)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (May 23, 2024)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (May 23, 2024)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (June 4, 2024)

April 12, 2023 — 7 citations

Citations issued on April 12, 2023
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (July 31, 2023)
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (July 31, 2023)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (July 31, 2023)
K-0351Install an approved automatic sprinkler system.Deficient, Provider has date of correction (July 31, 2023)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (July 31, 2023)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (July 31, 2023)
K-0920Ensure proper usage of power strips and extension cords.Deficient, Provider has date of correction (July 31, 2023)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.