Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Estates Healthcare and Rehabilitation Center

Fort Worth, TX · 141 certified beds · Last Life Safety survey May 1, 2026

CMS Certification Number 675028 · first certified December 1991

Ownership

Operated by CREATIVE SOLUTIONS IN HEALTHCARE · For profit - Corporation

  • Ownership changed February 1, 2023 (change of ownership)from DIVERSICARE ESTATES LLC
27
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
7
Tags cited more than once
Across separate surveys
15
Inspection & testing records
Of the citations on file

Position within TX

27 citations — more than 98% of the 1,177 certified nursing homes in TX. Compared within TX rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 8 citations; the earlier surveys in the window averaged 9.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens June 2027 — about 8 months from now. This facility’s last Life Safety survey was May 2026. Facilities in TX are typically surveyed 13–14 months after the last one (median 14), measured over 1,905 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about Estates Healthcare and Rehabilitation Center

One email when it happens. No account; stop it any time with one click.

Which alerts

6 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Emergency preparedness

2 of the 27 citations on file are Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

14 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 27 Life Safety citations above. The Physical Environment Index

  • F-0880 Provide and implement an infection prevention and control program.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0908 Keep all essential equipment working safely.

How that compares

Citations on file over three years

Compared with the median facility in TX, and nationally. Surveyors differ markedly between states, so the TX figure is the meaningful one.

This facility27TX median7National median11
Citations on file over three years, compared
MeasureCitations
This facility27
Median facility in TX7
Median facility nationally11

Survey history

Citations at each Life Safety survey
112024-0182025-0282026-05
Citations at each Life Safety survey
Survey dateCitations
January 5, 202411
February 14, 20258
May 1, 20268

Most-cited tags

Most-cited tags at this facility
K-03243K-09183K-03722K-07122K-03742K-05112K-03532K-03431
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0324Provide properly protected cooking facilities.32026-05-01
K-0918Have generator or other power source capable of supplying service within 10 seconds.32026-05-01
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.22026-05-01
K-0712Have simulated fire drills held at unexpected times.22026-05-01
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.22025-02-14
K-0511Have properly installed electrical wiring and gas equipment.22026-05-01
K-0353Inspect, test, and maintain automatic sprinkler systems.22025-02-14
K-0343Have a fire alarm with audible and visual signals that transmits the alarm automatically to notify emergency forces in event of fire.12025-02-14

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 13
  • Gas, Vacuum, and Electrical Systems Deficiencies 4
  • Miscellaneous Deficiencies 4
  • Egress Deficiencies 2
  • Other 4
Citations by CMS category
CategoryCitations
Smoke Deficiencies13
Gas, Vacuum, and Electrical Systems Deficiencies4
Miscellaneous Deficiencies4
Egress Deficiencies2
Services Deficiencies2
Emergency Preparedness Deficiencies2

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

May 1, 2026 — 8 citations

Citations issued on May 1, 2026
TagWhat the surveyor checksStatus
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (May 4, 2026)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (May 4, 2026)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (May 4, 2026)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (May 4, 2026)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (May 4, 2026)
K-0741Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.Deficient, Provider has date of correction (May 4, 2026)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (May 4, 2026)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (May 4, 2026)

February 14, 2025 — 8 citations

Citations issued on February 14, 2025
TagWhat the surveyor checksStatus
E-0006Conduct risk assessment and an All-Hazards approach.Deficient, Provider has date of correction (February 14, 2025)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (February 14, 2025)
K-0343Have a fire alarm with audible and visual signals that transmits the alarm automatically to notify emergency forces in event of fire.Deficient, Provider has date of correction (February 14, 2025)
K-0351Install an approved automatic sprinkler system.Deficient, Provider has date of correction (March 21, 2025)
K-0352Properly install and monitor supervisory attachments on automatic sprinkler systems.Deficient, Provider has date of correction (March 14, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (February 14, 2025)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (February 14, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (March 14, 2025)

January 5, 2024 — 11 citations

Citations issued on January 5, 2024
TagWhat the surveyor checksStatus
E-0020Establish policies and procedures including evacuation.Deficient, Provider has date of correction (January 5, 2024)
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (February 2, 2024)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (January 5, 2024)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (January 5, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (January 10, 2024)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (January 5, 2024)
K-0374Install smoke barrier doors that can resist smoke for at least 20 minutes.Deficient, Provider has date of correction (January 5, 2024)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (January 5, 2024)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (January 5, 2024)
K-0900Meet Health Care Facilities Code mechanical requirements.Deficient, Provider has date of correction (January 5, 2024)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (January 5, 2024)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.