Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Twin Pines Nursing and Rehabilitation

Victoria, TX · 200 certified beds · Last Life Safety survey February 20, 2026

CMS Certification Number 675638 · first certified October 1996

Ownership

Operated by CREATIVE SOLUTIONS IN HEALTHCARE · For profit - Corporation

  • Ownership changed September 1, 2022 (change of ownership)from CITIZENS MEDICAL CENTER COUNTY OF VICTORIA
16
Citations on file
CMS's current file
3
Life Safety surveys
CMS's current file
5
Tags cited more than once
Across separate surveys
13
Inspection & testing records
Of the citations on file

Position within TX

16 citations — more than 87% of the 1,177 certified nursing homes in TX. Compared within TX rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Holding steadyabout the same at the latest survey as at its earlier surveys in CMS's current file.

The latest survey found 5 citations; the earlier surveys on file averaged 5.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens April 2027 — about 5 months from now. This facility’s last Life Safety survey was February 2026. Facilities in TX are typically surveyed 13–14 months after the last one (median 14), measured over 1,923 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to about three years in Virginia. How the window is measured

Get an email about Twin Pines Nursing and Rehabilitation

One email when it happens. No account; stop it any time with one click.

Which alerts

4 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities cited for sprinkler inspection and testing in CMS’s current file are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

9 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 16 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.
  • F-0919 Make sure that a working call system is available in each resident's bathroom and bathing area.
  • F-0584 Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.
  • F-0921 Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public.

How that compares

Citations in CMS's current file

Compared with the median facility in TX, and nationally. Surveyors differ markedly between states, so the TX figure is the meaningful one.

This facility16TX median7National median11
Citations in CMS's current file, compared
MeasureCitations
This facility16
Median facility in TX7
Median facility nationally11

Survey history

Citations at each Life Safety survey
52023-1062024-1252026-02
Citations at each Life Safety survey
Survey dateCitations
October 13, 20235
December 6, 20246
February 20, 20265

Most-cited tags

Most-cited tags at this facility
K-03722K-03452K-05112K-05212K-09292K-03241K-09181K-03551
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.22024-12-06
K-0345Have approved installation, maintenance and testing program for fire alarm systems.22026-02-20
K-0511Have properly installed electrical wiring and gas equipment.22026-02-20
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.22024-12-06
K-0929Ensure precautions for handling oxygen cylinders and equipment are correctly followed.22024-12-06
K-0324Provide properly protected cooking facilities.12024-12-06
K-0918Have generator or other power source capable of supplying service within 10 seconds.12026-02-20
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.12026-02-20

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 8
  • Gas, Vacuum, and Electrical Systems Deficiencies 4
  • Services Deficiencies 4
Citations by CMS category
CategoryCitations
Smoke Deficiencies8
Gas, Vacuum, and Electrical Systems Deficiencies4
Services Deficiencies4

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

February 20, 2026 — 5 citations

Citations issued on February 20, 2026
TagWhat the surveyor checksStatus
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (February 20, 2026)
K-0352Properly install and monitor supervisory attachments on automatic sprinkler systems.Deficient, Provider has date of correction (February 20, 2026)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (February 20, 2026)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (February 20, 2026)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (February 20, 2026)

December 6, 2024 — 6 citations

Citations issued on December 6, 2024
TagWhat the surveyor checksStatus
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (January 3, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (January 3, 2025)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (January 3, 2025)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (January 3, 2025)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (January 3, 2025)
K-0929Ensure precautions for handling oxygen cylinders and equipment are correctly followed.Deficient, Provider has date of correction (January 3, 2025)

October 13, 2023 — 5 citations

Citations issued on October 13, 2023
TagWhat the surveyor checksStatus
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (November 10, 2023)
K-0372Ensure smoke barriers are constructed to a 1 hour fire resistance rating.Deficient, Provider has date of correction (November 10, 2023)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (October 12, 2023)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (November 10, 2023)
K-0929Ensure precautions for handling oxygen cylinders and equipment are correctly followed.Deficient, Provider has date of correction (November 10, 2023)

Reflects the CMS posting of October 1, 2026. Surveys conducted in the last few months may not appear yet.